Plan Review Stops For Permit 15080805 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-11-05 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-11-05 |
Time |
07:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-09-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-09-26 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-09-26 |
Time |
12:14 |
Sent To |
|
|
Notes |
2015-09-26 13:55:02 | | | BUILDING PLAN REVIEW | | W. P. B. REVISION: 15080805 | | W. P. B. PERMIT: 14050097 | | ADD: 8100 IBIS BLVD. | | CONT: THE WEITZ CO. | | TEL: (561)686-5511 | | E-MAIL: | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: SAT. SEPT. 26/2015 | | ACTION: DENIED | | | | 1) SHEET GI102 LIFE SAFETY PLAN UPPER LEVEL, PLEASE | | REVIEW THE BAR TERRACE 214 WITH A OCCUPANT LOAD OF 167 | | OCCUPANTS. WHEN OCCUPANT LOADS ARE GREATER THAN 49 | | OCCUPANTS, 2 EXITS ARE REQUIED, TABLE 1015.1. THIS | | SHEET SHOWS THE 2ND MEANS OF EGRESS FROM THE TERRACE | | GOING BACK INSIDE THE BUILDING. SECTION 1027.1 STATES | | ONCE YOU HAVE LEFT THE EXIT YOU ARE IN THE EXIT | | DISCHARGE, THE EXIT DISCHARGE SHALL NOT REENTER THE | | BUILDING. | | | | 2) SHEET GI102. THE FIRE REVIEW HAS ALSO POINTED OUT | | THE PINCH POINT AT THE MAIN ENTRY WHERE THE OCCUPANT | | LOAD OF 591 PERSONS WHICH EQUATES TO A REQUIRED EGRESS | | WIDTH OF 9FT. 10 1/4 INCHES. THE LOBBY ONLY HAS 8 FT 6 | | INCHES IN WIDTH. 1005.1 MINIMUM REQUIRED EGRESS WIDTH. | | | | 3) SHEET GI102. THE OTHER ISSUE IS 2 MEANS OF EGRESS | | FROM BOTH ROOMS 225 A & 225B WHEN MORE THAN 49 OCCUPANT | | ARE IN A ROOM, 2 EXIT ACCESS DOORWAYS ARE REQUIRED, IN | | A SPRINKLERED BUILDING THE DOORWAYS NEED TO BE 1/3RD OF | | THE OVERALL DIAGONAL DISTANCE APART. 1015.2.1 EXCEP. # | | 2. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-09-24 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-09-24 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-09-24 |
Time |
13:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2015-09-02 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-09-02 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-09-02 |
Time |
09:20 |
Sent To |
|
|
Notes |
2015-09-02 09:21:00 | MINOR PAVING |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-10-28 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-10-28 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-10-28 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-09-22 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-09-22 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-09-22 |
Time |
16:45 |
Sent To |
|
|
Notes |
2015-09-22 17:04:43 | 8100 IBIS BOULEVARD | | TRACKING #15080805 | | PERMIT #14050097 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SHEET GI102: ENTRY LOBBY #201 INDICATES AN OCCUPANT | | LOAD OF 591 PERSONS WHICH EQUATES TO A REQUIRED EGRESS | | WIDTH OF 9.85 FEET ((591 X 0.2) / 12)). THE LOBBY | | CREATES AN EGRESS PINCH POINT OF ONLY 8.7 FEET OF | | EGRESS WIDTH. | | | | SHEET GI102: PRIVATE MEETING ROOMS #225A & #225B HAD | | TWO EXIT ACCESS DOORS. NOW THE ROOMS ONLY INDICATE 1 | | EXIT ACCESS DOOR. TWO ARE REQUIRED FOR ASSEMBLY USE | | SPACES. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-11-05 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-10-23 |
Time |
16:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-10-01 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-10-01 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-27 |
Time |
08:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-11-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-11-04 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-04 |
Time |
11:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-09-10 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-09-10 |
Time |
13:52 |
Sent To |
|
|
Notes |
2015-09-10 13:56:40 | 1ST REVIEW: FBC 2010 MECHANICAL | | REVISION #15080805 | | MASTER #14050097 | | 9/10/15 | | | | 1) IN ORDER TO EXPEDITE THE REVIEW PROCESS, PLEASE | | SUBMIT A NARRATIVE THAT CLEARLY IDENTIFIES ALL THE | | REVISIONS THAT WERE MADE TO THE APPROVED MECHANICAL | | PLANS. IN ADDITION, PLEASE CLOUD ALL THE REVISIONS ON | | THE PLANS AND PROVIDE DELTA TRIANGLE SYMBOLS AT EACH | | REVISION LOCATION. | | 2) SHEET M102 INDICATES A "NEW AHU-1.9" PROVIDE AN | | EQUIPMENT SCHEDULE FOR THE NEW UNIT AND CLARIFY IF THIS | | WAS JUST A SAME-SIZE REPLACEMENT, AR ACTUALLY A NEW AC | | UNIT. PLEASE NOTE THAT COOLING AND HEATING CALCULATIONS | | ARE REQUIRED FOR NEW SYSTEMS- REFER TO SECTION C403.2.1 | | FBC-14 ENERGY CONSERVATION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2015-11-15 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-15 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-13 |
Time |
11:52 |
Sent To |
|
|
Notes |
2015-11-13 11:52:32 | PEDDS GIVEN TO SKENNEDY |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-11-04 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2015-11-04 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2015-11-04 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-09-30 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2015-09-30 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2015-09-30 |
Time |
17:01 |
Sent To |
|
|
Notes |
2015-09-30 17:03:20 | 9/30/15- FAILED. PLANS DO NOT MATCH LATEST APPROVED | | PLANS. | | | | ANGELLA VANN | | 561-822-1441 | | [email protected] |
|
|