Plan Review Details - Permit 15080805
Plan Review Stops For Permit 15080805
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-11-05 Cont ID  
Sent By jwitmer Date 2015-11-05 Time 09:00 Rev Time 0.00
Received By jwitmer Date 2015-11-05 Time 07:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-26 Cont ID  
Sent By jwitmer Date 2015-09-26 Time 14:15 Rev Time 0.00
Received By jwitmer Date 2015-09-26 Time 12:14 Sent To  
Notes
2015-09-26 13:55:02 
 BUILDING PLAN REVIEW
 W. P. B. REVISION: 15080805
 W. P. B. PERMIT: 14050097
 ADD: 8100 IBIS BLVD.
 CONT: THE WEITZ CO.
 TEL: (561)686-5511
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. SEPT. 26/2015
 ACTION: DENIED
  
 1) SHEET GI102 LIFE SAFETY PLAN UPPER LEVEL, PLEASE
 REVIEW THE BAR TERRACE 214 WITH A OCCUPANT LOAD OF 167
 OCCUPANTS. WHEN OCCUPANT LOADS ARE GREATER THAN 49
 OCCUPANTS, 2 EXITS ARE REQUIED, TABLE 1015.1. THIS
 SHEET SHOWS THE 2ND MEANS OF EGRESS FROM THE TERRACE
 GOING BACK INSIDE THE BUILDING. SECTION 1027.1 STATES
 ONCE YOU HAVE LEFT THE EXIT YOU ARE IN THE EXIT
 DISCHARGE, THE EXIT DISCHARGE SHALL NOT REENTER THE
 BUILDING.
  
 2) SHEET GI102. THE FIRE REVIEW HAS ALSO POINTED OUT
 THE PINCH POINT AT THE MAIN ENTRY WHERE THE OCCUPANT
 LOAD OF 591 PERSONS WHICH EQUATES TO A REQUIRED EGRESS
 WIDTH OF 9FT. 10 1/4 INCHES. THE LOBBY ONLY HAS 8 FT 6
 INCHES IN WIDTH. 1005.1 MINIMUM REQUIRED EGRESS WIDTH.
  
 3) SHEET GI102. THE OTHER ISSUE IS 2 MEANS OF EGRESS
 FROM BOTH ROOMS 225 A & 225B WHEN MORE THAN 49 OCCUPANT
 ARE IN A ROOM, 2 EXIT ACCESS DOORWAYS ARE REQUIRED, IN
 A SPRINKLERED BUILDING THE DOORWAYS NEED TO BE 1/3RD OF
 THE OVERALL DIAGONAL DISTANCE APART. 1015.2.1 EXCEP. #
 2.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-09-24 Cont ID  
Sent By albarran Date 2015-09-24 Time 13:22 Rev Time 0.00
Received By skennedy Date 2015-09-24 Time 13:22 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2015-09-02 Cont ID  
Sent By cranford Date 2015-09-02 Time 09:21 Rev Time 0.00
Received By cranford Date 2015-09-02 Time 09:20 Sent To  
Notes
2015-09-02 09:21:00MINOR PAVING

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-10-28 Cont ID  
Sent By wjolin Date 2015-10-28 Time 15:26 Rev Time 0.00
Received By wjolin Date 2015-10-28 Time 15:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-09-22 Cont ID  
Sent By wjolin Date 2015-09-22 Time 17:12 Rev Time 0.00
Received By wjolin Date 2015-09-22 Time 16:45 Sent To  
Notes
2015-09-22 17:04:438100 IBIS BOULEVARD
 TRACKING #15080805
 PERMIT #14050097
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET GI102: ENTRY LOBBY #201 INDICATES AN OCCUPANT
 LOAD OF 591 PERSONS WHICH EQUATES TO A REQUIRED EGRESS
 WIDTH OF 9.85 FEET ((591 X 0.2) / 12)). THE LOBBY
 CREATES AN EGRESS PINCH POINT OF ONLY 8.7 FEET OF
 EGRESS WIDTH.
  
 SHEET GI102: PRIVATE MEETING ROOMS #225A & #225B HAD
 TWO EXIT ACCESS DOORS. NOW THE ROOMS ONLY INDICATE 1
 EXIT ACCESS DOOR. TWO ARE REQUIRED FOR ASSEMBLY USE
 SPACES.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-11-05 Cont ID  
Sent By jwitmer Date 2015-11-05 Time 09:00 Rev Time 0.00
Received By jwitmer Date 2015-10-23 Time 16:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-10-01 Cont ID  
Sent By lmarchan Date 2015-10-01 Time 17:32 Rev Time 0.00
Received By skennedy Date 2015-08-27 Time 08:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-11-04 Cont ID  
Sent By ccole Date 2015-11-04 Time 11:57 Rev Time 0.00
Received By ccole Date 2015-11-04 Time 11:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-09-10 Cont ID  
Sent By ccole Date 2015-09-10 Time 13:52 Rev Time 0.00
Received By ccole Date 2015-09-10 Time 13:52 Sent To  
Notes
2015-09-10 13:56:401ST REVIEW: FBC 2010 MECHANICAL
 REVISION #15080805
 MASTER #14050097
 9/10/15
  
 1) IN ORDER TO EXPEDITE THE REVIEW PROCESS, PLEASE
 SUBMIT A NARRATIVE THAT CLEARLY IDENTIFIES ALL THE
 REVISIONS THAT WERE MADE TO THE APPROVED MECHANICAL
 PLANS. IN ADDITION, PLEASE CLOUD ALL THE REVISIONS ON
 THE PLANS AND PROVIDE DELTA TRIANGLE SYMBOLS AT EACH
 REVISION LOCATION.
 2) SHEET M102 INDICATES A "NEW AHU-1.9" PROVIDE AN
 EQUIPMENT SCHEDULE FOR THE NEW UNIT AND CLARIFY IF THIS
 WAS JUST A SAME-SIZE REPLACEMENT, AR ACTUALLY A NEW AC
 UNIT. PLEASE NOTE THAT COOLING AND HEATING CALCULATIONS
 ARE REQUIRED FOR NEW SYSTEMS- REFER TO SECTION C403.2.1
 FBC-14 ENERGY CONSERVATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2015-11-15 Cont ID  
Sent By skennedy Date 2015-11-15 Time 10:32 Rev Time 0.00
Received By skennedy Date 2015-11-13 Time 11:52 Sent To  
Notes
2015-11-13 11:52:32PEDDS GIVEN TO SKENNEDY

Review Stop Z ZONING
Rev No 2 Status P Date 2015-11-04 Cont ID  
Sent By ajones Date 2015-11-04 Time 15:01 Rev Time 0.00
Received By ajones Date 2015-11-04 Time 15:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-09-30 Cont ID  
Sent By ajones Date 2015-09-30 Time 17:01 Rev Time 0.00
Received By ajones Date 2015-09-30 Time 17:01 Sent To  
Notes
2015-09-30 17:03:209/30/15- FAILED. PLANS DO NOT MATCH LATEST APPROVED
 PLANS.
  
 ANGELLA VANN
 561-822-1441
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved