Plan Review Stops For Permit 15080661 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-12-15 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-12-15 |
Time |
09:39 |
Sent To |
|
|
Notes |
2015-12-15 09:44:03 | ****PROVISO**** | | ****REVISION MAY BE REQUIRED SUBJECT TO INSPECTOR'S | | DISCRETION**** | | | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. UPON BUILDING INSPECTION, THE DCA/DBPR INSIGNIA WILL | | BE REMOVED AND RETURNED TO DBPR | | | | 2. A DOOR IS TO BE REMOVED AND WALL INFILL INSTALLED. | | PROVIDE A STRUCTURAL DETAIL WHICH INCLUDES WIND DESIGN | | CRITERIA (FBC 1603.1.4) AT INSPECTION. | | | | 3. THE PLANS FOR STAIRS, RAMP, LANDING, RAILING ARE | | DEFICIENT. IT REFERS TO THE WRONG CODE, AN OLD VERSION | | OF ASCE7, AND IS LACKING THE DIMENSIONS WHICH SHOULD | | SHOW COMPLIANCE. REVISE PLANS TO SHOW COMPLIANCE WITH | | ALL REQUIREMENTS OF FBC 5TH EDITION ACCESSIBILITY | | (DIMENSIONS). DETAILS NOT NEEDED FOR THIS JOB CAN BE | | CROSSED OUT AND DO NOT NEED TO DEMONSTRATE COMPLIANCE. | | | | 4. SEPARATE PERMIT FOR SHUTTERS REQUIRED WITH A | | SEPARATE APPLICATION, PLANS AND FEES. A PRODUCT | | APPROVAL AND THE FOLLOWING FORM ARE TO BE SUBMITTED: | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-10-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-10-30 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-10-27 |
Time |
15:17 |
Sent To |
|
|
Notes |
2015-10-28 09:33:06 | ****CORRECTIONS**** | | | | A DCA APPROVED MANUFACTURED BUILDING IS PROPOSED, WITH | | MODIFICATIONS - PERMIT WILL BE ISSUED WITH PROVISO | | THAT, UPON BUILDING INSPECTION, THE DCA/DBPR INSIGNIA | | WILL BE REMOVED AND RETURNED TO DBPR. | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1 OK | | 2 OK | | | | 3. A DOOR IS TO BE REMOVED AND WALL INFILL INSTALLED. | | PROVIDE A STRUCTURAL DETAIL AND INCLUDE WIND DESIGN | | CRITERIA FBC 1603.1.4. | | | | 4. OK | | | | 5. DETAIL 3 SK5, SEAT HEIGHT NOT CLEAR, FBC 5TH ED | | ACCESSIBILITY 604.4, PLEASE REVISE TO CLARIFY. DETAIL 2 | | SK5, PROVIDE LAV HEIGHT AND KNEE CLEARANCE, 606.3. | | 2ND REVIEW, DISTANCE TO TOP OF LID (NOT SEAT) IS SHOWN | | AS BOTH 1FT4IN AND 1FT5IN WHICH WOULD BE 16 AND 17 | | INCHES, SO SEAT WOULD BE LOWER, BUT SEAT IS REQUIRED TO | | BE BETWEEN 17 AND 19 INCHES. THIS CAN BE A REDLINED | | ITEM UPON REQUEST. | | | | 5. THE PLANS FOR STAIRS, RAMP, LANDING, RAILING ARE | | DEFICIENT. IT REFERS TO THE WRONG CODE, AN OLD VERSION | | OF ASCE7, AND IS LACKING THE DIMENSIONS WHICH SHOULD | | SHOW COMPLIANCE. REVISE PLANS TO SHOW COMPLIANCE WITH | | ALL REQUIREMENTS OF FBC 5TH EDITION ACCESSIBILITY | | (DIMENSIONS). DETAILS NOT NEEDED FOR THIS JOB CAN BE | | CROSSED OUT AND DO NOT NEED TO DEMONSTRATE COMPLIANCE. | | | | 6. SHEET SP1 SHOWS 38.8 FT FROM PROPOSED SALES OFFICE | | TO EXISTING RESNICK BUILDING. REVISE TO SHOW ASSUMED | | PROPERTY LINE BETWEEN THE TWO BUILDINGS, FBC 705.3 AND | | SHOW COMPLIANCE WITH FBC TABLES 602, 705.8. | | | | 2ND REVIEW, PAGE WAS REVISED TO SHOW A DISTANCE OF 28.8 | | BUT THE ASSUMED PROPERTY LINE, DISTANCE FROM EACH | | BUILDING TO THE ASSUMED PROPERTY LINE, COMPLIANCE WITH | | TABLES 602, 705.8 NOT SHOWN. PLEASE CONTACT ME IF YOU | | WISH TO DISCUSS. | | | | 7. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED, | | OR PROVIDE REMOVAL AGREEMENT REQUESTED BY WILLIE SWOPE, | | 561 233 5025. | | | | 8. IMPACT PROTECTION REQUIRED, SEE SITE INSTALLED | | ITEMS, FBC 1609.1.4. IF SHUTTERS ARE PROPOSED, PROVIDE | | THE PRODUCT APPROVAL AND COMPLETE THE SAMPLE | | INSTALLATION SCHEDULE: | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | THIS CAN BE A PROVISO ITEM, SEPARATE PERMIT REQUIRED. A | | PRODUCT APPROVAL WAS PROVIDED BUT THE FORM WAS NOT | | INCLUDED. | | | | 9. SHEET A4 IS NOT A PART OF THE MODULAR STATE | | APPROVAL. REVISE TO UPDATE TO CURRENT CODE, REVISE | | PLANS TO COMPLY WITH CURRENT CODE, AND ALSO SEE FBC | | 1809.4 REGARDING FOOTING DEPTH. | | | | | | WHEN RESUBMITTING, PLEASE REMOVE THE OLD SHEETS FROM | | THE COLLATED PERMIT DOCUMENTS BUT RETAIN IN THE | | SUBMITTAL FOR REFERENCE. PLEASE RETAIN THE VOIDED | | REFERENCE ONLY 2010 MODULAR PLANS. PLEASE SEE ME OR | | STEVE KENNEDY IF YOU NEED ASSISTANCE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-09-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-09-18 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-09-18 |
Time |
12:54 |
Sent To |
|
|
Notes |
2015-09-18 13:34:34 | ****CORRECTIONS**** | | COURTESY REVIEW - SCOPE CLARIFIED | | A DCA APPROVED MANUFACTURED BUILDING IS PROPOSED, WITH | | MODIFICATIONS | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. BASED ON THE SITE PLAN PROVIDED, IT APPEARS THAT THE | | PROPOSED LOCATION FOR THIS SALES TRAILER IS 4847 FRED | | GLADSTONE DRIVE. SUBMIT A CHANGE OF ADDRESS THROUGH THE | | FRONT COUNTER OR REVISE THE SITE PLAN TO SHOW THE | | PROPOSED SALES TRAILER RELATIVE TO THE LOT LINES, FBC | | 107. | | | | 2. FS 553.80, PROVIDE THE STATE APPROVED PLANS AND | | STATE APPROVAL COVER SHEET WHICH SHOWS THE APPROVAL | | NUMBER. THIS SHOULD BE ON THE INSIGNIA. | | | | ADVISORY ONLY, PLANS PREPARED BY REBECCA M. GATES WERE | | NOT YET REVIEWED BY FIRE (FIRE HAD PLANS CHECKED OUT | | WHEN THESE SHEETS WERE SUBMITTED) BUT WILL BE REVIEWED | | WHEN PLANS ARE RESUBMITTED. | | | | PERMIT WILL BE ISSUED WITH PROVISO THAT, UPON BUILDING | | INSPECTION, THE DCA/DBPR INSIGNIA WILL BE REMOVED AND | | RETURNED TO DBPR. | | | | REVISE PLANS PREPARED BY REBECCA M. GATES TO INCLUDE | | GOVERNING CODE. | | | | IN ADDITION TO THE CHANGE IN FLOOR PLAN, IT APPEARS | | THAT A DOOR HAS BEEN ELIMINATED AND A WINDOW IS | | PROPOSED, BUT NO DETAIL WAS PROVIDED. PROVIDE A | | STRUCTURAL DETAIL AND INCLUDE WIND DESIGN CRITERIA FBC | | 1603.1.4. A PRODUCT APPROVAL REVIEWED BY DESIGNER OF | | RECORD REQUIRED. | | | | 3. PER ATCOUNCIL.ORG, THIS LOCATION IS RISK CATEGORY II | | 167 MPH. PLANS SUBMITTED ARE LIMITED TO 165 MPH, SEE | | SHEET C1, FBC 1609. PER THE STATE OF FLORIDA, IF AN | | EXISTING MANUFACTURED (MODULAR) BUILDING IS MOVVED TO A | | NEW LOCATION, THE RELOCATED BUILDING SHALL COMPLY WITH | | THE WIND SPEED OF THE NEW LOCATION. | | | | THE MANUFACTURED BUILDING PLANS AS SUBMITTED DO NOT | | COMPLY WITH THE WIND SPEED REQUIREMENT FOR THE | | LOCATION. PLEASE ADDRESS, EITHER BY PROVIDING A NEW | | MANUFACTURED BUILDING WHICH COMPLIES WITH 167MPH WIND | | SPEED, OR BY PROVIDING ENGINEERING TO INCREASE THE | | LIMITATION FOR THE BUILDING PROPOSED FROM 165MPH TO | | 167MPH. | | | | 4. SHOW 18 IN MANEUVERING CLEARANCE FOR DOORS, PULL | | SIDE, FBC ACCESSIBILITY 404.2.4.1, ROOMS 4 AND 5. | | | | 5. DETAIL 3 SK5, SEAT HEIGHT NOT CLEAR, FBC 5TH ED | | ACCESSIBILITY 604.4, PLEASE REVISE TO CLARIFY. DETAIL 2 | | SK5, PROVIDE LAV HEIGHT AND KNEE CLEARANCE, 606.3. | | | | 5. STAIR, RAMP, LANDING, RAILING DETAILS NOT PROVIDED, | | FBC CHAPTER 10, FBC ACCESSIBILITY. | | | | 6. SHEET SP1 SHOWS 38.8 FT FROM PROPOSED SALES OFFICE | | TO EXISTING RESNICK BUILDING. REVISE TO SHOW ASSUMED | | PROPERTY LINE BETWEEN THE TWO BUILDINGS, FBC 705.3 AND | | SHOW COMPLIANCE WITH FBC TABLES 602, 705.8. | | | | 7. FOR IMPACT FEES, EITHER: | | | | A. PROVIDE THE REMOVAL AGREEMENT WHEREIN OWNER AGREES | | THAT THE PROPOSED TEMPORARY SALES TRAILER WILL BE | | REMOVED BY A CERTAIN DATE (PER WILLIE SWOPE), OR | | | | B. AN IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS | | REQUIRED. 561-233-5025 FOR MORE INFORMATION; PROVIDE | | THE STAMPED PLAN AND RECEIPT SHOWING FEES WERE PAID, IF | | APPLICABLE. | | | | IF CONTRACTOR DOES NOT UNDERSTAND ITEM A, TAKE PLANS TO | | PALM BEACH COUNTY FOR IMPACT FEE ASSESSMENT. | | | | 8. IMPACT PROTECTION REQUIRED, SEE SITE INSTALLED | | ITEMS, FBC 1609.1.4. IF SHUTTERS ARE PROPOSED, PROVIDE | | THE PRODUCT APPROVAL AND COMPLETE THE SAMPLE | | INSTALLATION SCHEDULE: | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | THIS CAN BE A PROVISO ITEM, SEPARATE PERMIT REQUIRED. | | | | 9. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED | | SETS OF PLANS FOR PERMIT ISSUANCE. OLD SHEETS SHOULD BE | | MARKED "VOID" AND LEFT IN THE PERMIT APPLICATION | | PACKAGE. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-09-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-09-14 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-09-11 |
Time |
12:58 |
Sent To |
|
|
Notes |
2015-09-12 14:26:35 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. BASED ON THE SITE PLAN PROVIDED, IT APPEARS THAT THE | | PROPOSED LOCATION FOR THIS SALES TRAILER IS 4847 FRED | | GLADSTONE DRIVE. SUBMIT A CHANGE OF ADDRESS THROUGH THE | | FRONT COUNTER OR REVISE THE SITE PLAN TO SHOW THE | | PROPOSED SALES TRAILER RELATIVE TO THE LOT LINES, FBC | | 107. | | | | 2. SCOPE NOT CLEAR, FBC 107. | | | | COMPLETE PLANS WERE SUBMITTED FOR A "MODULAR | | STRUCTURE." PLEASE SEE FS 553.80, MODULAR STRUCTURES | | REQUIRE PLAN REVIEW AND APPROVAL BY THE STATE. IF THE | | MODULAR INSTALLATION IS PROPOSED, PROVIDE THE STATE | | APPROVED PLANS AND STATE APPROVAL COVER SHEET WHICH | | SHOWS THE APPROVAL NUMBER. THIS SHOULD BE ON THE | | INSIGNIA. | | | | SOMEONE ADDED PAGES AT SOME POINT IN THE REVIEW | | PROCESS. IF THESE PAGES WERE SUBMITTED AFTER OTHER | | REVIEWS WERE COMPLETE, RE-REVIEW BY THOSE TRADES IS | | REQUIRED. NO RESUBMITTAL FORM WAS PROVIDED. | | | | IF THE PLANS PREPARED BY REBECCA M. GATES ARE PROPOSED | | RATHER THAN THE PLAN WHICH APPEARS TO BE A DCA APPROVED | | MODULAR, PLEASE NOTE THE FOLLOWING PER STATE OF | | FLORIDA: | | | | CAN AN EXISTING MODULAR BUILDING BE MODIFIED OR | | RENOVATED? | | | | YES. ONSITE MODIFICATIONS TO EXISTING MODULAR BUILDINGS | | MUST BE PERMITTED AND INSPECTED BY THE JURISDICTION | | HAVING AUTHORITY (LOCAL BUILDING DEPARTMENT). ORIGINAL | | PLANS (OR ?AS-BUILT? PLANS) AND ANY MODIFICATIONS MUST | | BE PROVIDED TO THE LOCAL BUILDING DEPARTMENT. WHEN | | INSPECTED BY THE LOCAL BUILDING DEPARTMENT, THE | | DCA/DBPR INSIGNIA SHALL BE REMOVED AND RETURNED TO | | DBPR, AND A CERTIFICATE OF OCCUPANCY BE ISSUED IN LIEU | | OF THE DCA/DBPR INSIGNIA. RECERTIFICATION BY THE LOCAL | | JURISDICTION IS ONLY APPLICABLE FOR THAT JURISDICTION | | (NOT STATEWIDE). | | | | PLANS PREPARED BY REBECCA M. GATES SHOULD INCLUDE | | GOVERNING CODE. THE MODULAR PLANS ARE REQUIRED TO BE | | UPDATED TO CURRENT CODE. | | | | IN ADDITION TO THE CHANGE IN FLOOR PLAN, IT APPEARS | | THAT A DOOR HAS BEEN ELIMINATED AND A WINDOW IS | | PROPOSED, BUT NO DETAIL WAS PROVIDED. PROVIDE A | | STRUCTURAL DETAIL AND INCLUDE WIND DESIGN CRITERIA FBC | | 1603.1.4. A PRODUCT APPROVAL REVIEWED BY DESIGNER OF | | RECORD REQUIRED. | | | | A COMPLETE CHECKLIST CANNOT BE PROVIDED AS INTENT IS | | NOT ENTIRELY CLEAR. | | | | 3. PER ATCOUNCIL.ORG, THIS LOCATION IS RISK CATEGORY II | | 167 MPH. PLANS SUBMITTED ARE LIMITED TO 165 MPH, SEE | | SHEET C1, FBC 1609. PER THE STATE OF FLORIDA, IF AN | | EXISTING MANUFACTURED (MODULAR) BUILDING IS MOVVED TO A | | NEW LOCATION, THE RELOCATED BUILDING SHALL COMPLY WITH | | THE WIND SPEED OF THE NEW LOCATION. | | | | 4. SHOW 18 IN MANEUVERING CLEARANCE FOR DOORS, PULL | | SIDE, FBC ACCESSIBILITY 404.2.4.1, ROOMS 4 AND 5. | | | | 5. FOR THE NEW FLOOR PLAN, PROVIDE DETAILS WHICH SHOW | | COMPLIANCE WITH ALL REQUIREMENTS OF FBC 5TH EDITION | | ACCESSILIBITY. | | | | 5. STAIR, RAMP, LANDING, RAILING DETAILS NOT PROVIDED, | | FBC CHAPTER 10, FBC ACCESSIBILITY. | | | | 6. SHEET SP1 SHOWS 38.8 FT FROM PROPOSED SALES OFFICE | | TO EXISTING RESNICK BUILDING. REVISE TO SHOW ASSUMED | | PROPERTY LINE BETWEEN THE TWO BUILDINGS, FBC 705.3 AND | | SHOW COMPLIANCE WITH FBC TABLES 602, 705.8. | | | | 7. FOR IMPACT FEE PURPOSES, PROVIDE THE REMOVAL | | AGREEMENT WHEREIN OWNER AGREES THAT THE PROPOSED | | TEMPORARY SALES TRAILER WILL BE REMOVED BY A CERTAIN | | DATE (PER WILLIE SWOPE). IF THIS DOCUMENT CANNOT BE | | PROVIDED, AN IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY | | IS REQUIRED. 561-233-5025 FOR MORE INFORMATION. | | | | 8. IMPACT PROTECTION REQUIRED, SEE SITE INSTALLED | | ITEMS, FBC 1609.1.4. IF SHUTTERS ARE PROPOSED, PROVIDE | | THE PRODUCT APPROVAL AND COMPLETE THE SAMPLE | | INSTALLATION SCHEDULE: | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-04-05 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-04-05 |
Time |
16:26 |
Sent To |
|
|
Notes |
2016-04-05 17:47:42 | ELECTRICAL REVIEW COMMENTS | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION OF THE FBC 2014 & NFPA 70 (NEC) 2011 | | EDITION | | | | CORRECTIONS REQUIRED: | | 1. THE RISER DIAGRAM SHOWS THE SERVICE AS 277/480 3 | | PHASE GOING INTO A STEP DOWN TRANSFORMER TO 120/208 BUT | | THE SERVICE REQUIREMENT AS PER THE PANEL SCHEDULE IS | | 120/240 3 PHASE GOING INTO A 3 PHASE DISC. OF WHICH TWO | | PHASES ARE BEING USED. | | 2. THE PANEL SCHEDULE ON THE PRIMARY PERMIT HAS A | | DEMAND LOAD OF 54.8 AMP AND THE PANEL SCHEDULE ON THE | | NEW PLANS HAVE A CONNECTED DEMAND LOAD OF 73.6 AMP. | | SUBMIT SPECS | | 3. THE RISER DOES NOT INDICATE THE CONDUCTOR INSULATION | | RATING THEREFORE ASSUMING IT IS 60 DEGREE, THE MAXIMUM | | DISTANCE BETWEEN THE MAIN DISC AND THE TRAILERS DISC IS | | ONLY 136'. | | 4. PHYSICAL PROTECTION AS REQUIRED IN NEC 110.27(B) | | SHALL BE PROVIDED AND INDICATED ON PLANS. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-12-16 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-12-16 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-12-16 |
Time |
13:36 |
Sent To |
Z |
|
Notes |
2015-12-16 14:48:12 | CONDITIONAL APPROVAL OF THIS PERMIT IS ISSUED SUBJECT | | TO FIELD INSPECTOR APPROVAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-10-05 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-10-05 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-10-05 |
Time |
17:47 |
Sent To |
I |
|
Notes |
2015-10-05 18:11:03 | AFTER A TELEPHONE CALL FROM RYAN TEMPONE I WENT BACK TO | | TAKE A SECOND LOOK AT THE DISARRAY SUBMITTED AND FOUND | | THE TWO OTHER SHEETS WHICH ADDRESSED THE DEFICIENCIES I | | HAD NOTED PREVIOUSLY. I TOOK ALL THE ELECTRICAL PAGES | | AND STAPLED THEM TOGETHER. I WAS ALSO INFORMED BY MR. | | TEMPONE OF THEIR INTENT TO REARRANGE THE INTERIOR | | LAYOUT OF THE TRAILERS, TO WHICH I TOLD HIM TO REVISE | | THE SCOPE OF THE PERMIT APPLICATION TO REFLECT THAT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-10-05 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-10-05 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-10-05 |
Time |
13:54 |
Sent To |
I |
|
Notes |
2015-10-05 14:55:14 | THIS SET OF DRAWINGS WAS SO SLOPPY THAT I ACCIDENTLY | | STAMPED THE PLANS AS PASSED. PLEASE NOTE THAT .I | | COMPARED THE PANEL SCHEDULES SUBMITTED I NOTICED A | | MISMATCH. CORRECT THE SUBMITTAL SO THAT THE LOAD CALCS | | AND THE PANEL SCHEDULES MATCH ON BOTH SET OF DRAWINGS. | | FURTHERMORE, PROVIDE A SITE PLAN INDICATING THE | | LOCATION OF THE SOURCE OF POWER AND MAIN DISCONNECT. | | WHEN YOU RESUBMIT, PLEASE STAPLE ALL THE SHEETS OF EACH | | SET AND ATTACH THEM TO THE MANUFACTURERS DRAWINGS FOR | | COMPARISON. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-11-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-11-05 |
Time |
08:24 |
Sent To |
Z |
|
Notes |
2015-11-05 09:22:20 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | CONSIDER THE PREVIOUS COMMENTS AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-08-26 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-08-26 |
Time |
0900 |
Sent To |
|
|
Notes |
2015-11-05 09:21:40 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | CONSIDER THE PREVIOUS COMMENTS AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | 2015-08-26 09:18:10 | 8/26/2015 PASSED WITH PROVISO: | | | | 1. PER NFPA 241- STANDARD FOR SAFEGUARDING | | CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, | | SECTION 4.2 TEMPORARY CONSTRUCTION TRAILERS SHALL BE | | SEPARATED FROM ADJACENT TRAILERS OR STRUCTURES IN | | ACCORDANCE WITH TABLE 4.2.1. PER TABLE 4.2.1: | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | 2. PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | 3. PER SECTION 18.3.4.1 (NFPA 1), FIRE HYDRANTS SHALL | | BE PROVIDED WITH CLEARANCES OF 7?-6? TO THE FRONT AND | | SIDES AND 4? TO THE BACKSIDE. | | | | 4. PER SECTION 18.2.3.4.1.1 (NFPA 1), FIRE DEPARTMENT | | ACCESS ROADS SHALL HAVE A SURFACE DESIGNED TO | | ACCOMMODATE FIRE APPARATUS WEIGHING AT LEAST 32 TONS. | | ACCESS ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF NOT | | LESS THAN 20 FEET AND AN UNOBSTRUCTED VERTICAL | | CLEARANCE OF NOT LESS THAN 13 FEET 6 INCHES. | | | | STAIRS FOR TRAILERS | | | | 5. GUARDS, AT LEAST 42-INCHES TALL, SHALL BE PROVIDED | | AT THE OPEN SIDES OF MEANS OF EGRESS (STAIRS, | | MEZZANINE, ETC.) THAT EXCEED 30-INCHES ABOVE THE FLOOR. | | OPEN GUARDS SHALL PROHIBIT THE PASSAGE OF A 4-INCH | | DIAMETER SPHERE UP TO A HEIGHT OF 34-INCHES. THE | | TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD AND | | BOTTOM ELEMENT OF THE GUARDRAIL SHALL PROHIBIT THE | | PASSAGE OF A 6-INCH DIAMETER SPHERE. | | | | HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR. | | HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND | | NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD, | | MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE | | LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE | | RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT | | NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A | | DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN | | 2 INCHES. | | | | STAIR RISERS SHALL BE BETWEEN 4 INCHES AND 7 INCHES IN | | HEIGHT. STAIRS SHALL BE SLIP RESISTANT AND HAVE A | | MINIMUM TREAD DEPTH OF 11 INCHES AND PREVENT THE | | ACCUMULATION OF WATER. | | | | STAIRS SHALL HAVE LANDINGS AT DOOR OPENINGS. | | | | STAIRS AND EGRESS COMPONENTS SHALL CONFORM TO THE LIFE | | SAFETY REQUIREMENTS OF CHAPTER 7 OF NFPA 101 FLORIDA | | 2012 EDITION. | | | | 6. PROVIDE ILLUMINATED EXIT SIGNS FOR ALL EXIT DOORS. | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM IS | | REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP DRAWINGS, | | ARE REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY | | THE FIRE PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | GJT | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-01-08 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-01-08 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-01-05 |
Time |
16:00 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-12-17 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2015-12-03 |
Time |
13:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-11-24 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-11-24 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2015-10-15 |
Time |
07:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-10-05 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-10-05 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-08-18 |
Time |
09:19 |
Sent To |
|
|
Notes |
2015-10-05 14:58:29 | 10/5/15 FAILED REVIEWS. CONTRACTOR NOTIFIED VIA EMAIL. | | SENT TO LARGE DENIED BIN "W". MA | 2015-08-19 09:19:29 | B31 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
N |
Date |
2016-01-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-01-08 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-01-08 |
Time |
12:11 |
Sent To |
|
|
Notes |
2016-01-08 12:11:42 | TEMPORARY SALES TRAILER - IMPACT FEES NOT REQUIRED PER | | WILLIE SWOPE; SEE EMAIL | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2015-12-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-12-15 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-12-15 |
Time |
11:15 |
Sent To |
|
|
Notes |
2015-12-15 11:15:12 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED | | 561-233-5025 | | | | WHEN RESUBMITTING, PLEASE COLLATE TWO IDENTICAL SETS OF | | PLANS WITH ALL VOIDED SHEETS REMOVED. THE VOIDED SHEETS | | SHOULD BE RETAINED IN THE PACKAGE BUT BOUND SEPARATELY | | FROM THE PLANS FOR ISSUANCE. | | | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2015-10-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-10-30 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-10-27 |
Time |
16:15 |
Sent To |
|
|
Notes |
2015-10-30 17:18:08 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED | | 561-233-5025 | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-09-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-09-12 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-09-12 |
Time |
16:21 |
Sent To |
|
|
Notes |
2015-09-12 16:22:10 | SEE BUILDING COMMENTS | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-11-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-11-03 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-03 |
Time |
12:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-09-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-09-03 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-09-03 |
Time |
15:50 |
Sent To |
|
|
Notes |
2015-09-14 08:30:39 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #15080661 | | 9/14/15 | | | | 1) PLEASE SUBMIT REVISED HVAC PLANS, DETAILS, AND | | SPECIFICATIONS TO MATCH THE NEW SALES OFFICE PLANS BY | | ARCHITECT GATES. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-10-26 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-10-26 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-10-26 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-09-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-03 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-03 |
Time |
06:23 |
Sent To |
|
|
Notes |
2015-09-03 06:06:16 | 1) PLEASE BIND ALL THE PLANS INTO TWO COMPLETE SETS FOR | | REVIEW. | | 2) SHT. SK-2 THE STAFF ROOM SINK SHALL COMPLY WITH THE | | FBC-ACCESSIBILITY SEC.212.1, 606. | | 3) SHT. SK-5 - SHOW THE HEIGHT OF THE WATER CLOSET TO | | THE TOP OF THE SEAT. COMPLY WITH 2014 FBC-ACCESSIBILITY | | SEC. 604.4. | | 4) SHT. SK-5 - SHOW THE DIMENSIONSTO THE BOTTOM & TOP | | OF THE LAVATORY FROM THE FINISH FLOOR. COMPLY WITH 2014 | | FBC-ACCESSIBILITY SECS.606.2,606.3. | | 5) SHOW THE DIMENSIONS OF THE TOILET ROOM ON THE PLANS. | | WPB AMEND. TO FBC SEC. 107.2.1. | | 6) SHT.P0.1 - A BACKFLOW PREVENTION DEVICE SHALL BE | | INSTALLED ON THE WATER SERVICE PER FBC-P SEC.608.1 | | 7) THE FLOOR PLAN ON THE SK DRAWINGS DOES NOT CORRELATE | | WITH THE FLOOR PLAN OF THE MODULAR BUILDING.CLARIFY. | | 8) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FFOR THE | | EEMAX WATER HEATER. WPB AMEND. TO FBC SEC. 107.2.1. | | 9) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE WATER | | COOLER.WPB AMEND. TO FBC SEC. 107.2.1. | | 10) SHOW THE LOCATION OF THE WATER COOLER ON THE FLOOR | | PLAN. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2016-01-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-01-08 |
Time |
08:17 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2016-01-07 |
Time |
10:07 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2015-12-17 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-12-17 |
Time |
09:03 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2015-12-16 |
Time |
17:21 |
Sent To |
|
|
Notes |
2015-12-17 09:58:58 | FAILED | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | 1) REPEAT COMMENT: THE CIVIL SITE PLAN DOES NOT MATCH | | THE COTLEUR & HEARING SITE PLAN. ALL PLANS SHALL SHOW | | SAME CONDITION. | | | | 2) REPEAT COMMENT: PRIOR TO ZONING APPROVAL OF THIS | | PERMIT, THE LANDSCAPE PLAN SHALL BE SUBMITTED AS A | | SEPARATE PERMIT, WITH PLANS. THE LANDSCAPE PLAN SHALL | | REFLECT THE RAMP AND STAIRS FOR THE PUBLIC TO ACCESS | | THE SALES TRAILER. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-11-23 |
Time |
17:27 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2015-11-23 |
Time |
17:27 |
Sent To |
|
|
Notes |
2015-11-23 17:32:17 | FAILED | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | 1) THE CIVIL SITE PLAN DOES NOT MATCH THE COTLEUR & | | HEARING SITE PLAN. ALL PLANS SHALL SHOW SAME CONDITION. | | | | 2) PRIOR TO ZONING APPROVAL OF THIS PERMIT, THE | | LANDSCAPE PLAN SHALL BE SUBMITTED AS A SEPARATE PERMIT, | | WITH PLANS. THE LANDSCAPE PLAN SHALL REFLECT THE RAMP | | AND STAIRS FOR THE PUBLIC TO ACCESS THE SALES TRAILER. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-09-11 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-09-11 |
Time |
17:12 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2015-09-11 |
Time |
17:12 |
Sent To |
B |
|
Notes |
2015-09-11 17:18:21 | FAILED | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | 1) PROVIDE A REVISED SITE PLAN THAT SHOWS THE ADA RAMPS | | AND THE STAIRS THAT ARE REQUIRED FOR THE PUBLIC TO | | ACCESS THE SALES TRAILER. | | | | 2) PRIOR TO ZONING APPROVAL OF THIS PERMIT, THE | | LANDSCAPE PLAN SHALL BE SUBMITTED AS A SEPARATE PERMIT, | | WITH PLANS. THE LANDSCAPE PLAN SHALL REFLECT THE RAMP | | AND STAIRS FOR THE PUBLIC TO ACCESS THE SALES TRAILER. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | 2015-08-31 11:19:23 | 8/31/15 |
|
|