Plan Review Stops For Permit 15080504 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-10-31 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-31 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-31 |
Time |
12:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-10-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-19 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-19 |
Time |
09:08 |
Sent To |
|
|
Notes |
2015-10-19 09:17:42 | 1ST REVIEW: FBC 2014 5TH ED. | | | | AS INDICATED ON THE FIRST REVIEW, THE SCOPE OF WORK IS | | STILL NOT FULLY CLEAR. PROVIDE CLARITY PER FBC 107 AS | | PREVIOUSLY REQUESTED. | | | | PLEASE CLARIFY WETHER THE DOORS & WINDOWS ARE TO BE | | REPLACED OR ARE EXISTING. THE PLAN INDICATES BOTH. | | | | PROVIDE DETAIL FOR THE INFILL CBS WALL AT THE LOCATION | | OF THE 96" SGD. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-08-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-14 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-14 |
Time |
10:59 |
Sent To |
Z |
|
Notes |
2015-08-14 11:07:35 | 1ST REVIEW: FBC 2014 5TH ED. | | | | THE CODE IN EFFECT CITED IS OUTDATED. THIS APPEARS TO | | BE A LEVEL I ALTERATION OF A SFD PER THE FBC EXISTING | | BUILDING CODE 5TH EDITION. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. | | | | THERE IS A LACK OF DETAIL AND SCOPE OF WORK INDICATED | | AND ONLY GENERAL PARAMETERS GIVEN. PROVIDE ADDITIONAL | | DETAIL TO DEMONSTARTE THE FOLLOWING: | | | | INTERIOR WALL TYPICAL DETAIL, FURRING AND DRYWALL | | DETAIL, SPECIFY ROOF JOIST THAT MAY BE REPLACED, | | SPECIFY IF NEW OPENING IN WALL REQUIRES STRUCTURAL | | SUPPORT TO THE ROOF MEMBERS. | | | | PLEASE NOTE A COMPLETE REVIEW CANNOT BE PERFORMED DUE | | TO THE LACK OF INFORMATION PROVIDED. | | | | ADDITIONALLY, THE SCOPE OF WORK IN DICATES WORK THAT | | MAY EXCEED THE THE CLAIMED VALUE OF $7,000.00. PER FBC | | 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | PROVIDE A COPY OF YOUR CONTRACT TO DETERMINE THE SCOPE | | OF WORK AND VALUE OF THE JOB. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-10-31 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-31 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-31 |
Time |
12:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-10-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-06 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-06 |
Time |
15:13 |
Sent To |
|
|
Notes |
2015-10-06 15:17:13 | 2ND REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | REVISE THE PLAN TO COMPLY WITH THE FOLLOWING SECTION: | | FBCR-E3703.2 KITCHEN AND DINING AREA RECEPTACLES. | | A MINIMUM OF TWO 20-AMPERE-RATED BRANCH CIRCUITS SHALL | | BE PROVIDED TO SERVE ALL WALL AND FLOOR RECEPTACLE | | OUTLETS LOCATED IN THE KITCHEN, PANTRY, BREAKFAST AREA, | | DINING AREA OR SIMILAR AREA OF A DWELLING. THE KITCHEN | | COUNTERTOP RECEPTACLES SHALL BE SERVED BY A MINIMUM OF | | TWO 20-AMPERE-RATED BRANCH CIRCUITS, EITHER OR BOTH OF | | WHICH SHALL ALSO BE PERMITTED TO SUPPLY OTHER | | RECEPTACLE OUTLETS IN THE SAME KITCHEN, PANTRY, | | BREAKFAST AND DINING AREA INCLUDING RECEPTACLE OUTLETS | | FOR REFRIGERATION APPLIANCES. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-08-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-14 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-14 |
Time |
09:31 |
Sent To |
|
|
Notes |
2015-08-14 10:14:33 | 1ST REVIEW: FBC 2014 5TH ED./ NEC2011 | | | | NO ELECTRICAL DETAILS ARE PROVIDED; ELECTRICAL | | MODIFICATIONS ARE REQUIRED IN THE NEWLY ARRANGED | | KITCHEN, BEDROOMS, AND THE BATHROOM AND TO FOR THE A/C | | CONDENSER RELOCATION AND FOR ASSURANCE OF SMOKE AND CO | | DETECTORS. PROVIIDE AN ELECTRICAL PLAN PER THE MINIMUM | | CRITERIA OF FBC 107 AND DEMONSTRATE COMPLIANCE WITH THE | | FOLLOWING: | | | | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO | | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. | | FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 | | FEET OF EACH SLEEPING ROOM. | | NEC 210.52 (B) (3) - KITCHEN COUNTER TOP RECEPTACLES | | SHALL BE SUPPLIED BY NO FEWER THAN TWO SMALL APPLIANCE | | BRANCH CIRCUITS. | | NEC 210.63 - PROVIDE A GFI SERVICE OUTLET FOR WITHIN | | 25? OF MECHANICAL EQUIPMENT. | | NEC 210.52(A)(1)&(2) OUTLET SPACING, IT APPEARS SOME | | POINTS ALONG THE WALL EXCEED 6? FROM AN OUTLET WHERE | | WALLS ARE BEING MODIFIED. | | NEC 210.12B - OUTLETS TO BE AFCI PROTECTED. | | NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2015-10-08 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-10-08 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-10-08 |
Time |
12:15 |
Sent To |
|
|
Notes |
2015-10-08 12:16:34 | GAS PLAN REVIEW | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | SPECIFICATIONS AND GAS RISER THAT REFLECTS THE ENTIRE | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | 107.2.1. | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | FBC-R, SEC. G2404.3. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2015-10-08 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-10-05 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-10-05 |
Time |
15:59 |
Sent To |
|
|
Notes |
2015-10-05 15:58:45 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | | | GAS COMMENTS: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | SEC. 402.4.1. | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | PSI. | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | SEC. 502 THRU 505. | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-10-01 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-10-01 |
Time |
10:09 |
Sent To |
|
|
Notes |
2015-10-01 10:10:01 | WINDOW GRID PATTERN TO BE CONSISTENT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-10-31 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-31 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-22 |
Time |
09:56 |
Sent To |
|
|
Notes |
2015-10-22 09:56:27 | RESUB ROUTED TO SKENNEDY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-10-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-19 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-09-18 |
Time |
15:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-08-25 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-25 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-14 |
Time |
09:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2015-11-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-11-02 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-11-02 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-10-05 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-05 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-05 |
Time |
15:22 |
Sent To |
P |
|
Notes |
2015-10-05 15:23:25 | 1ST REVIEW: FBC 2014 5TH ED. | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2015-10-31 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-31 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-31 |
Time |
12:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2015-10-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-19 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-19 |
Time |
08:13 |
Sent To |
|
|
Notes |
2015-10-19 09:07:28 | 3RD REVIEW: FBC 2014 5TH ED. | | | | A PLAN AND PARTIALLY COMPLETED ENERGY FORM HAS BEEN | | SUPPLIED. THE IS NOT ACCEPTABLE AS THE DUCT MATERIAL | | AND DIMENSIONS OF VARIOUS PORTIONS OF THE DUCT SYSTEM | | ARE NOT IDENTIFIED. THE ENERGY SUBMITTAL IS NOT FILLED | | OUT, THERE IS NO EQUIPMENT SIZING CALCULATION PROVIDED. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN | | | | FBC-ER403.6.1 PROVIDE A SIZING CALCULATION. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2015-10-05 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-05 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-05 |
Time |
15:20 |
Sent To |
|
|
Notes |
2015-10-05 15:21:11 | 2ND REVIEW: FBC 2014 5TH ED. | | | | THERE WAS NO MECHANICAL OR IN THE ORIGINAL NOR THE | | RE-SUBMITTAL. THE COMMENTS BELOW ARE REPEAT COMMENTS. | | | | THERE IS A LACK OF DETAIL AND INFORMATION TO DETERRMINE | | COMPLIANCE WITH THE MECHANICAL CODE. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. | | | | WHAT ARE YOU DOING IN TERMS OF RELOCATING THE AHU? IF | | PLACING IN THE ATTIC, PROVIDE DETAIL TO DEMONSTRATE | | COMPLIANCE WITH THE FOLLOWING: | | | | FBC-R M1305.1.3 APPLIANCES IN ATTICS. | | ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN | | OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT | | NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM) LONG | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES | | (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE | | APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS | | OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY | | 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW | | REMOVAL OF THE LARGEST APPLIANCE. | | | | FBC-R M1305.1.3.1 ELECTRICAL REQUIREMENTS. | | A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE | | REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET | | SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN | | ACCORDANCE WITH CHAPTER 34. | | | | FBC-R M1305.1.3.2 AIR-HANDLING UNITS. | | AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS IF THE | | FOLLOWING CONDITIONS ARE MET: | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | 2. A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT THE | | UNIT DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING | | PROPERLY. | | 3. THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | REPLACE THE AIR HANDLER. | | 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | CAPITALS, IN 16 POINT TYPE, WITH THE TITLE AND FIRST | | PARAGRAPH IN BOLD: | | | | | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-08-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-14 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-14 |
Time |
10:20 |
Sent To |
|
|
Notes |
2015-08-14 10:49:59 | 1ST REVIEW: FBC 2014 5TH ED. | | | | THERE IS A LACK OF DETAIL AND INFORMATION TO DETERRMINE | | COMPLIANCE WITH THE MECHANICAL CODE. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. | | | | WHAT ARE YOU DOING IN TERMS OF RELOCATING THE AHU? IF | | PLACING IN THE ATTIC, PROVIDE DETAIL TO DEMONSTRATE | | COMPLIANCE WITH THE FOLLOWING: | | | | FBC-R M1305.1.3 APPLIANCES IN ATTICS. | | ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN | | OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT | | NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM) LONG | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES | | (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE | | APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS | | OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY | | 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW | | REMOVAL OF THE LARGEST APPLIANCE. | | | | FBC-R M1305.1.3.1 ELECTRICAL REQUIREMENTS. | | A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE | | REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET | | SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN | | ACCORDANCE WITH CHAPTER 34. | | | | FBC-R M1305.1.3.2 AIR-HANDLING UNITS. | | AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS IF THE | | FOLLOWING CONDITIONS ARE MET: | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | 2. A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT THE | | UNIT DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING | | PROPERLY. | | 3. THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | REPLACE THE AIR HANDLER. | | 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | CAPITALS, IN 16 POINT TYPE, WITH THE TITLE AND FIRST | | PARAGRAPH IN BOLD: | | | | | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
N |
Date |
2015-10-31 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-31 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-31 |
Time |
12:09 |
Sent To |
|
|
Notes |
2015-10-31 12:14:41 | SEE 15100140 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2015-10-08 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-10-08 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-10-08 |
Time |
11:15 |
Sent To |
|
|
Notes |
2015-10-08 11:18:13 | PLUMBING APPROVED.SEE PERMIT APPLICATION # 15100140 FOR | | PLUMBING FOR THIS STRUCTURE.PLUMBING SUB-PERMIT NOT | | REQUIRED UNDER THIS PERMIT. A SEPARATE PERMIT IS | | REQUIRED FOR THE GAS. T.LARGE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-10-05 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-10-05 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-10-05 |
Time |
15:46 |
Sent To |
|
|
Notes |
2015-10-05 15:55:22 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | 1. LAUNDRY STACK SHALL CONNECT DOWN STREAM OFF BATHROOM | | GROUP.ONLY THE FIXTURES WITHIN THE BATHROOM GROUPS | | SHALL CONNECT TO THE WET-VENTED HORIZONTAL BRANCH | | DRAIN. ANY ADDITIONAL FIXTURES SHALL DISCHARGE | | DOWNSTREAM OF THE HORIZONTAL WET VENT. | | PER FBC P SEC 912.1 | | 2. PROVIDE WATER RISER DIGRAM PER WPB AMEND. SEC | | 107.3.5.3(11) |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2015-08-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-14 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-14 |
Time |
10:14 |
Sent To |
|
|
Notes |
2015-08-14 10:52:57 | THERE DOES NOT APPEAR TO BE PLUMBING REQUIRING A PERMIT | | IN THE SCOPE OF WORK. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2015-10-05 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-05 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-05 |
Time |
15:31 |
Sent To |
|
|
Notes |
2015-10-05 15:19:19 | ROOFING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-10-01 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-10-01 |
Time |
10:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-08-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-08-21 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-08-21 |
Time |
16:59 |
Sent To |
|
|
Notes |
|
|