Plan Review Details - Permit 15080161
Plan Review Stops For Permit 15080161
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-12-21 Cont ID  
Sent By rmcdouga Date 2015-12-21 Time 13:31 Rev Time 0.00
Received By rmcdouga Date 2015-12-21 Time 12:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-11-13 Cont ID  
Sent By rmcdouga Date 2015-11-13 Time 15:28 Rev Time 0.00
Received By rmcdouga Date 2015-11-13 Time 15:28 Sent To  
Notes
2015-11-13 13:22:43PLAN
 REVIEW COMMENTS
 3RD REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PERMIT APPLICATION IS MISSING FROM THE PERMIT
 DOCUMENTS.
  
 2) THE PRODUCT APPROVALS FOR THE WINDOW AND DOOR ARE
 MISSING FROM THE PERMIT DOCUMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-26 Cont ID  
Sent By rmcdouga Date 2015-10-26 Time 09:16 Rev Time 0.00
Received By rmcdouga Date 2015-10-23 Time 17:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-08-27 Cont ID  
Sent By rmcdouga Date 2015-08-27 Time 10:27 Rev Time 0.00
Received By rmcdouga Date 2015-08-26 Time 18:15 Sent To  
Notes
2015-08-27 08:59:00PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) BASED ON FBC - R301.2.1.4.3, THE PROJECT IS LOCATED
 IN EXPOSURE CATEGORY D. THE PLANS SPECIFY EXPOSURE
 CATEGORY C.
  
 2) REVISE THE COMPONENT AND CLADDING DESIGN PRESSURES
 TO EXPOSURE CATEGORY D. FBC-R 301.1
  
 3) THE ENERGY CODE (FORM R402-2014) REQUIRES THE WALL
 INSULATION TO BE R-13. THE WALL SECTION SPECIFIES R-11.
  
 4) UPDATE THE CODE EDITIONS AS FOLLOWS. THESE ARE THE
 EDITIONS REFERENCED IN THE 2014 FBC. THE 2011 NATIONAL
 ELECTRICAL CODE, NFPA 101 - 2012, AND THE 2014 FIRE
 PREVENTION CODE.
  
 5) THE WALL SECTION SPECIFIES ONLY ONE LAYER OF 30#
 FELT ON THE EXTERIOR WALL UNDER THE LATH AND STUCCO.
 R703.6.3 WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS
 REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER
 WOOD-BASED SHEATHING, SHALL INCLUDE A WATER-RESISTIVE
 VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST
 EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE
 INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH
 THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE
 AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION
 R703.8) INTENDED TO DRAIN TO THE WATER-RESISTIVE
 BARRIER IS DIRECTED BETWEEN THE LAYERS.
  
 6) FBC - R704 INSPECTION FOR TERMITES IN ORDER TO
 PROVIDE FOR INSPECTION FOR TERMITE INFESTATION,
 CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL
 EARTH GRADE ON THE EXTERIOR OF A BUILDING SHALL NOT BE
 LESS THAN 6 INCHES (152 MM).
  
 7) FBC - R703.6.2.1 WEEP SCREEDS. A MINIMUM 0.019-INCH
 (0.5 MM) (NO. 26 GALVANIZED SHEET GAGE),
 CORROSION-RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED,
 WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 31/2
 INCHES (89 MM) SHALL BE PROVIDED AT OR BELOW THE
 FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN
 ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE
 PLACED A MINIMUM OF 4 INCHES (102 MM) ABOVE THE EARTH
 OR 2 INCHES (51 MM) ABOVE PAVED AREAS AND SHALL BE OF A
 TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE
 EXTERIOR OF THE BUILDING. THE WEATHER-RESISTANT BARRIER
 SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH
 SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF
 THE WEEP SCREED.
  
 9) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED BY THE DESIGNER OF RECORD. FBC 107.3.4
  
 10) SUBMIT TWO COPIES OF COVERSHEETS OR OTHER DOCUMENTS
 THAT SPECIFY THE FL NUMBER FOR THE JELD-WEN FRENCH
 DOORS. FBC 107.2.1
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-08-26 Cont ID  
Sent By rmcdouga Date 2015-08-26 Time 18:32 Rev Time 0.00
Received By rmcdouga Date 2015-08-26 Time 18:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-12-21 Cont ID  
Sent By rmcdouga Date 2015-12-21 Time 12:53 Rev Time 0.00
Received By rmcdouga Date 2015-11-12 Time 17:18 Sent To  
Notes
2015-11-12 17:18:49RMCDOUGAL DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-10-26 Cont ID  
Sent By rmcdouga Date 2015-10-26 Time 09:21 Rev Time 0.00
Received By rmcdouga Date 2015-10-26 Time 09:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-26 Cont ID  
Sent By rmcdouga Date 2015-10-26 Time 09:16 Rev Time 0.00
Received By rmcdouga Date 2015-10-15 Time 15:33 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-27 Cont ID  
Sent By rmcdouga Date 2015-08-27 Time 10:27 Rev Time 0.00
Received By rmcdouga Date 2015-08-05 Time 16:32 Sent To  
Notes
2015-08-05 16:32:47R18

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2016-01-12 Cont ID  
Sent By rmcdouga Date 2016-01-12 Time 14:41 Rev Time 0.00
Received By rmcdouga Date 2016-01-12 Time 14:41 Sent To  
Notes
2016-01-12 14:43:47MU2016-572, NO FEES WERE DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2015-11-13 Cont ID  
Sent By rmcdouga Date 2015-11-13 Time 13:18 Rev Time 0.00
Received By rmcdouga Date 2015-11-13 Time 13:18 Sent To  
Notes
2015-11-13 13:19:09BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-10-26 Cont ID  
Sent By rmcdouga Date 2015-10-26 Time 09:20 Rev Time 0.00
Received By rmcdouga Date 2015-10-26 Time 09:20 Sent To  
Notes
2015-10-26 09:20:46BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-08-26 Cont ID  
Sent By rmcdouga Date 2015-08-26 Time 18:26 Rev Time 0.00
Received By rmcdouga Date 2015-08-26 Time 18:26 Sent To  
Notes
2015-08-26 18:27:32BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-11-13 Cont ID  
Sent By rmcdouga Date 2015-11-13 Time 14:37 Rev Time 0.00
Received By rmcdouga Date 2015-11-13 Time 14:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-10-26 Cont ID  
Sent By rmcdouga Date 2015-10-26 Time 09:07 Rev Time 0.00
Received By rmcdouga Date 2015-10-23 Time 17:27 Sent To  
Notes
2015-10-26 09:16:20PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 THE TWO COMMENTS LISTED BELOW FROM THE FIRST REVIEW
 WERE NOT ADDRESSED.
  
 1) SUBMIT THE CURRENT ENERGY FORM. FORM 402-2010 WAS
 SUBMITTED AND FORM 402-2014 IS REQUIRED. 2014 FBC
 ENERGY CONSERVATION SECTION R101.5.1.1.1
  
 2) FORM 402-2014 IS REQUIRED TO BE SIGNED AND DATED BY
 THE OWNER/AGENT AND THE PREPARER. 2014 FBC ENERGY
 CONSERVATION SECTION R101.5.1.1.1
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-08-27 Cont ID  
Sent By rmcdouga Date 2015-08-27 Time 08:55 Rev Time 0.00
Received By rmcdouga Date 2015-08-26 Time 18:27 Sent To  
Notes
2015-08-27 08:55:39PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE DUCT SIZE, GRILL SIZE AND CFMS FOR THE
 NEW SUPPLY TO THE OFFICE SPACE. FBC 107.2.1
  
 2) SUBMIT THE CURRENT ENERGY FORM. FORM 402-2010 WAS
 SUBMITTED AND FORM 402-2014 IS REQUIRED. 2014 FBC
 ENERGY CONSERVATION SECTION R101.5.1.1.1
  
 3) FORM 402-2014 IS REQUIRED TO BE SIGNED AND DATED BY
 THE OWNER/AGENT AND THE PREPARER. 2014 FBC ENERGY
 CONSERVATION SECTION R101.5.1.1.1
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-08-10 Cont ID  
Sent By sgraham Date 2015-08-10 Time 14:30 Rev Time 0.00
Received By sgraham Date 2015-08-10 Time 14:30 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved