Plan Review Details - Permit 15071223
Plan Review Stops For Permit 15071223 |
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2015-09-21 |
|
|
Cont ID |
|
Sent By |
Mgonzale |
Date |
2015-09-21 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2015-09-21 |
Time |
|
Sent To |
FIRE |
|
Notes |
2015-09-21 14:44:39 | PASSED WITH PROVISO: | | | | #1 IT IS UNDERSTOOD THAT PRIOR BACFKLOW WAS VERTICALLY; | | HOWEVER THE PROPOSED BACFLOW MUST BE INSTALLED | | HORIZONTAL WHERE POSSIBLE. CONTACT UTILITY CUSTOMER | | SERVICE FOR INSPECTION. | | | | #2 DUE TO THE LOCATION OF THE BACKFLOW PLEASE RECORD IN | | PALM BEACH COUNTY COURTS THE BACKFLOW ASSEMBLY ACCESS | | COVENANT PRIOR TO FINAL INSPECTION PROVIDE A COPY TO | | CITY OF WEST PALM BEACH. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2015-08-08 |
|
|
Cont ID |
|
Sent By |
mGONZALE |
Date |
2015-08-07 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2015-08-07 |
Time |
|
Sent To |
M |
|
Notes |
2015-08-08 18:42:12 | #1 EXIST DCDA MUST BE APPROVED FOR LOCATION FROM CITY | | OF WPB UTILITIES CUSTOMER SERVICE. | | | | #2 EXIST. BACFLOW MUST BE IN HORIZONTAL CONFIGURATION. | | | | #3 EXIST BACFLOW MUST BE ACCESSIBLE TO CITY OF WPB | | UTILITIES CUSTOMER SERVICE. | | | | #4 SUBMIT A SPECIFICATION SHEET FOR DCDA FOR APPROVAL | | TO [email protected] CC. [email protected] | | REFERENCE YOUR PERMIT #. ALTHOUGH I UNDERSTAND THIS IS | | THE OLD LOCATION OF THE DCDA | | PLEASE CONTACT STEPHEN HUNTER (561) 644-7329 CITY OF | | WPB UTILITIES CUSTOMER SERVICE | | TO MAKE A SITE VISIT AND MAKE SURE ALL THE COMMENTS ARE | | ADDRESSED, | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-09-30 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-09-30 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-09-30 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-08-05 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-08-05 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-08-05 |
Time |
09:37 |
Sent To |
ENG |
|
Notes |
2015-08-05 10:32:58 | 114 SOUTH OLIVE AVENUE | | PERMIT #15071223 | | REVOKED PERMIT #14040237 | | MASTER #13060638 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | *****PROVISO - SUBMIT REVISION***** | | | | THE BACKFLOW PREVENTER (INDICATING CONTROL VALVES) | | SHALL BE LOCATED IN A FIRE RATED ENCLOSURE ACCESSIBLE | | FROM THE EXTERIOR OR IN ACCORDANCE WITH NFPA 24 SECTION | | 6.2.1. | | | | PROVIDE FIRE DEPARTMENT CONNECTION ALONG OLIVE AVENUE. | | THE CURRENT ALLEY PLACEMENT IS NOT DESIRABLE AND IS TOO | | GREAT A DISTANCE FROM THE NEAREST FIRE HYDRANT. PER | | NFPA 14 SECTION 6.4.5.1 FIRE DEPARTMENT CONNECTIONS | | SHALL BE VISIBLE AND RECOGNIZABLE FROM THE STREET OR | | NEAREST POINT OF FIRE DEPARTMENT APPARATUS | | ACCESSIBILITY OR ON THE STREET SIDE OF BUILDINGS. | | CONNECTIONS SHALL BE LOCATED NOT MORE THAN 100 FEET | | FROM THE NEAREST FIRE HYDRANT CONNECTED TO AN APPROVED | | WATER SUPPLY. | | | | PROVIDE LOCKING KNOX CAPS ON FIRE DEPARTMENT | | CONNECTION. | | | | CONFIRM THE RESTROOM STALL PARTITIONS ARE NOT SPRINKLER | | SPRAY OBSTRUCTIONS PER NFPA 13. ADDITIONAL SPRINKLERS | | MAY BE REQUIRED. | | | | ***NOTE: A SEPARATE PERMIT IS NEEDED FOR THE | | UNDERGROUND FIRE LINE (THIS MAIN IS NOT EXISTING)*** | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-09-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-09-21 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-08-18 |
Time |
15:23 |
Sent To |
|
|
Notes |
2015-08-18 15:23:59 | ENGINEERING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-08-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-08-11 |
Time |
12:07 |
Rev Time |
|
Received By |
ccole |
Date |
2015-07-31 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2015-08-11 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2015-08-08 |
Time |
18:54 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-08-11 |
Time |
12:07 |
Sent To |
|
|
Notes |
|
|
|