Plan Review Details - Permit 15071004
Plan Review Stops For Permit 15071004
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-09-04 Cont ID  
Sent By jwitmer Date 2015-09-04 Time 07:01 Rev Time 0.00
Received By jwitmer Date 2015-09-04 Time 06:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-07-29 Cont ID  
Sent By jwitmer Date 2015-07-29 Time 08:18 Rev Time 0.00
Received By jwitmer Date 2015-07-29 Time 07:44 Sent To  
Notes
2015-07-29 07:56:30BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15071004
 ADD: 1555 PALM BEACH LAKES BLVD. SUITE # 600
 CONT: FISHER
 TEL: ( 561)691-4716
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JULY 29/2015
 ACTION: DENIED
  
 1) PAGE LS-1 & A.1. CODE INVESTIGATION INDICATES THIS
 BUILDING IS BUILT TO THE BUILDING TYPE IIIA, PLEASE
 NOTE THIS IS A HIGH RISE BUILDING AND AT LEAST A TYPE
 IB, PLEASE INDICATE THE NUMBER OF STORIES IN THIS
 BUILDING TO CORRECTLY IDENTIFY THE MINIMUM BUILDING
 TYPE. SEE 2014 FBC-B TABLE 503.
  
 2) SHEET A-1.1 DETAIL # 4 SHOWS THE MICROWAVE SHELF AT
 A ELEVATION OF 4'-6". PLEASE PROVIDE COMPLIANCE WITH:
  
 2A) 2014 FBC-ACCESS. CODE SECTION 308.2.2 OBSTRUCTED
 HIGH REACH FRONT APPROACH.
  
 2B) 2014 FBC-ACCESS. CODE SECTION 308. 3.2 OBSTRUCTED
 HIGH REACH SIDE APPROACH.
  
 2C) 20104 FBC-ACCESS. CODE SECTION 209.3. OPERABLE
 PARTS.
  
 3) SHEET A-1 THE DOOR SCHEDULE DOORS 1 & 2 NOTE # 1
 PLEASE EXPLAIN NOTE, IT APPEARS THERE IS A CARD READER
 AT THE DOORS, PLEASE PROVIDE HOW WILL STAIRS BE
 ACCESSED? 2014 FBC-B 1021.1 EXITS FROM STORIES.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By ppetty Date 2015-08-24 Time 09:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-09-10 Cont ID  
Sent By scaldero Date 2015-09-10 Time 13:35 Rev Time 0.00
Received By scaldero Date 2015-09-10 Time 13:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-08-03 Cont ID  
Sent By scaldero Date 2015-08-03 Time 12:22 Rev Time 0.00
Received By scaldero Date 2015-08-03 Time 12:18 Sent To  
Notes
2015-08-03 12:21:57PERMIT # 15071004
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 COMMENTS:
  
 1) UPDATE THE CODE LIST TO REFERENCE THE 5TH EDITION OF
 THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE
 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA
 AMENDMENTS.
  
 2) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
 3) DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY
 THE FIRE DEPARTMENT AFTER ALL OTHER PLAN REVIEWER
 COMMENTS HAVE BEEN SATISFIED.
  
 SUE ELLEN CALDERON
 ASST. FIRE MARSHAL
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-09-11 Cont ID  
Sent By lmarchan Date 2015-09-10 Time 10:08 Rev Time 0.00
Received By lmarchan Date 2015-08-31 Time 15:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-24 Cont ID  
Sent By ppetty Date 2015-08-24 Time 10:01 Rev Time 0.00
Received By ppetty Date 2015-07-24 Time 16:25 Sent To  
Notes
2015-07-24 16:25:45C01

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-09-08 Cont ID  
Sent By ccole Date 2015-09-08 Time 10:52 Rev Time 0.00
Received By ccole Date 2015-09-08 Time 10:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-08-05 Cont ID  
Sent By ccole Date 2015-08-05 Time 08:24 Rev Time 0.00
Received By ccole Date 2015-08-05 Time 08:24 Sent To  
Notes
2015-08-05 08:38:501ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15071004
 8/5/15
  
 1) SHEET M-1: THE OUTSIDE AIR CALCULATION SCHEDULE IS
 REFERENCING THE OUTDATED ASHRAE 62.1- 2004. PLEASE
 REVIEW AND REVISE THE CALCULATIONS IN COMPLIANCE WITH
 SECTION 809.2 FBC-14 EXISTING BUILDING CODE: ALTERED
 EXISTING SYSTEMS.
 IN MECHANICALLY VENTILATED SPACES, EXISTING MECHANICAL
 VENTILATION SYSTEMS THAT ARE ALTERED, RECONFIGURED, OR
 EXTENDED SHALL PROVIDE NOT LESS THAN 5 CUBIC FEET PER
 MINUTE (CFM) (0.0024 M3/S) PER PERSON OF OUTDOOR AIR
 AND NOT LESS THAN 15 CFM (0.0071 M3/S) OF VENTILATION
 AIR PER PERSON; OR NOT LESS THAN THE AMOUNT OF
 VENTILATION AIR DETERMINED BY THE INDOOR AIR QUALITY
 PROCEDURE OF ASHRAE 62.
 2) M-2: THE AIR DISTRIBUTION TAG PRINT AT THE DIFFUSERS
 IS TOO SMALL TO READ. PLEASE ENLARGE EITHER THE TAGS OR
 THE ENTIRE DRAWING TO EXPEDITE THE REVIEW- SECTION
 107.2.1 WPB AMENDEMENTS TO THE FBC-14 BUILDING CODE.
 3) M-2: LABEL (VAV 6-7) ON THE PLAN AS "NEW"
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-09-03 Cont ID  
Sent By gjohnson Date 2015-09-03 Time 15:04 Rev Time 0.00
Received By gjohnson Date 2015-09-03 Time 15:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-08-06 Cont ID  
Sent By gjohnson Date 2015-08-06 Time 14:37 Rev Time 0.00
Received By gjohnson Date 2015-08-06 Time 13:11 Sent To  
Notes
2015-08-06 14:36:491ST REVIEW FBCP
  
 COMMENTS
  
 1.PLEASE PROVIDE RISER DIAGRAM FOR.
 [A] SANITARY FOR BREAK ROOM SINKS.
 [B]SANITARY FOR HUBDRAIN, PROVIDED FOR T+P AND PAN
 DRAIN.
 [B] WATER FOR BREAK ROOM SINKS.
 2. PLEASE PROVIDE SPECS FOR WATER HEATER.
 PER WPB AMENDMENTS TO THE FBCP SEC.107.2.1
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 EX. 561-805-6711
 [email protected]
  