Plan Review Stops For Permit 15071002 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-04-14 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-04-13 |
Time |
11:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-03-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-03-25 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-03-25 |
Time |
09:58 |
Sent To |
|
|
Notes |
2016-03-25 11:34:44 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15071002 | | ADD: 1415 S. OLIVE CONSTRUCTION TRAILERS | | CONT: GILBANE CONSTRUCTION | | TEL: (941)44-8062 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: FRI. MARCH 25/ 2016 | | ACTION: DENIED | | | | 1) SHEET A100 RAMP, STAIR, LANDING, HANDRAIL & | | GUARDRAIL DESIGNS SHOW PLANS SIGNED BY A ARCHIECT STATE | | OF GEORGIA SEAL. PLEASE REVIEW FLORIDA ADMINISTRTIVE | | CODE: | | 61G16 2.001 SEALS ACCEPTABLE TO THE BOARD. | | | | PURSUANT TO 492.107, F.S. AND CHAPTER 94-119, LAWS OF | | FLORIDA, THE BOARD HEREBY ESTABLISHES AS INDICATED | | BELOW THE FORMS OF METAL-TYPE IMPRESSION OR STAMPED INK | | SEALS WHICH ARE ACCEPTABLE TO THE BOARD. | | FLORIDA STATUTE 481.221(2) ?EACH REGISTERED ARCHITECT | | SHALL OBTAIN ONE SEAL IN A FORM APPROVED BY RULE OF THE | | BOARD .ALL FINAL CONSTRUCTION DOCUMENTS AND INSTRUMENTS | | OF SERVICE WHICH INCLUDE DRAWINGS, PLANS, | | SPECIFICATIONS, OR REPORTS PREPARED OR ISSUED BY THE | | REGISTERED ARCHITECT AND BEING FILED FOR PUBLIC RECORD | | SHALL BEAR THE SIGNATURE AND SEAL OF THE REGISTERED | | ARCHITECT WHO PREPARED OR APPROVED THE DOCUMENT AND THE | | DATE ON WHICH THEY WERE SEALED. | | | | PLEASE PROVIDE DETAILS FOR COMPLIANCE WITH THE | | ACCESSIBLE RAMP AND DECK. 107.3.5.1.1 MINIMUM PLAN | | REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. | | ACCESSIBLE PARKING FL ACC 505.2, 502.3 & 502.3.3 | | MARKING TO CITY STANDARD | | RAMPS 2014 FL ACC 405 RAMPS | | HANDRAILS/ GAURDRAILS 2014 FL ACCESS 505 | | | | 2) THE PLANS SUBMITTED FOR ANCHOR TIE DOWN BY ARCHITECT | | JOHN BODZIAK(SHEET 4 OF 4) ARE NOT SIGNED NOR SEALED, | | NOR ELECTONIC SIGNATURE. PURSUANT TO 492.107, F.S. AND | | CHAPTER 94-119, LAWS OF FLORIDA, THE BOARD HEREBY | | ESTABLISHES AS INDICATED BELOW THE FORMS OF METAL-TYPE | | IMPRESSION OR STAMPED INK SEALS WHICH ARE ACCEPTABLE TO | | THE BOARD. | | FLORIDA STATUTE 481.221(2) ?EACH REGISTERED ARCHITECT | | SHALL OBTAIN ONE SEAL IN A FORM APPROVED BY RULE OF THE | | BOARD .ALL FINAL CONSTRUCTION DOCUMENTS AND INSTRUMENTS | | OF SERVICE WHICH INCLUDE DRAWINGS, PLANS, | | SPECIFICATIONS, OR REPORTS PREPARED OR ISSUED BY THE | | REGISTERED ARCHITECT AND BEING FILED FOR PUBLIC RECORD | | SHALL BEAR THE SIGNATURE AND SEAL OF THE REGISTERED | | ARCHITECT WHO PREPARED OR APPROVED THE DOCUMENT AND THE | | DATE ON WHICH THEY WERE SEALED. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-09-10 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-09-10 |
Time |
07:00 |
Sent To |
|
|
Notes |
2015-09-10 07:33:55 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15071002 | | ADD: 1415 S. OLIVE CONSTRUCTION TRAILERS | | CONT: GILBANE CONSTRUCTION | | TEL: (941)44-8062 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION, | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. SEPT. 10/2015 | | ACTION: DENIED | | | | 1) SHEET EX-2 SITE PLANS SHOW AN ACCESSIBLE RAMP & DECK | | FOR ACCESS INTO THE JOBSITE TRAILERS. THE SITE PLAN | | ALSO SHOWS ACCESS FROM THE STREET BUT NO ACCESSIBLE | | PARKING SPACES. WITH SHOWING THESE DETAILS IT IS | | ASSUMED THAT THIS CONSTRUCTION OFFICE WILL HAVE | | MEETINGS AND NEED TO COMPLY WITH | | PART V (SECTION 553.501-553.513, FLORIDA STATUTES) | | RELATING TO ACCESSIBILITY BY PERSONS WITH DISABILITIES, | | AND PERMITS SHALL BE REQUIRED FOR STRUCTURAL SUPPORT | | AND TIE DOWN, ELECTRICAL SUPPLY, AND ALL UTILITY | | CONNECTIONS TO SUCH MOBILE OR MODULAR STRUCTURES. | | | | PLEASE PROVIDE DETAILS FOR COMPLIANCE WITH THE | | ACCESSIBLE RAMP AND DECK. 107.3.5.1.1 MINIMUM PLAN | | REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. | | ACCESSIBLE PARKING FL ACC 505.2, 502.3 & 502.3.3 | | MARKING TO CITY STANDARD | | RAMPS 2014 FL ACC 405 RAMPS | | HANDRAILS/ GAURDRAILS 2014 FL ACCESS 505 | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-08-20 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-20 |
Time |
16:33 |
Sent To |
|
|
Notes |
2015-09-10 08:33:08 | THIS IS AN INADVERTANT REVIEW. SEE REVIEW BY JWITMER. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-09-10 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-09-10 |
Time |
08:40 |
Sent To |
|
|
Notes |
2015-09-10 08:41:11 | BY SEPARATE PERMIT |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-03-11 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-03-11 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-03-11 |
Time |
13:02 |
Sent To |
|
|
Notes |
2016-03-11 13:18:49 | 1451 SOUTH OLIVE AVENUE | | PERMIT #15071002 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | OCCUPANCY OF THE CONSTRUCTION TRAILERS IS NOT PERMITTED | | UNTIL A #131 FIRE FINAL INSPECTION HAS BEEN PASSED. | | | | A SEPARATE PERMIT IS NEEDED FOR INSTALLING AUTOMATIC | | FIRE SPRINKLERS. | | | | PER SECTION 10.12.1.2 (NFPA 1), PROVIDE BUILDING | | ADDRESS VISIBLE FROM THE STREET. NUMBERS SHALL BE | | ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES IN | | HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE | | BACKGROUND. | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-08-26 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-08-26 |
Time |
15:43 |
Sent To |
|
|
Notes |
2015-08-26 15:58:07 | 1451 SOUTH OLIVE AVENUE | | PERMIT #15071002 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | OCCUPANCY OF THE CONSTRUCTION TRAILERS IS NOT PERMITTED | | UNTIL A #131 FIRE FINAL INSPECTION HAS BEEN PASSED. | | | | PROVIDE AN ADDRESS IN THE TITLEBLOCK CORRESPONDING TO | | THE TRAILER LOCATIONS. | | | | THE CITY OF WEST PALM BEACH REQUIRES CONSTRUCTION | | TRAILERS LARGER THAN A SINGLE "DOUBLE WIDE" (OR TWO | | "SINGLE WIDE") TO EITHER BE PROTECTED BY AN AUTOMATIC | | SPRINKLER SYSTEM OR COMPLY WITH THE SEPARATION | | REQUIREMENTS OF NFPA 241. | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | PER TABLE 4.2.1: | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | PER SECTION 10.12.1.2 (NFPA 1), PROVIDE BUILDING | | ADDRESS VISIBLE FROM THE STREET. NUMBERS SHALL BE | | ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES IN | | HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE | | BACKGROUND. | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | NO PLANS SUBMITTED FOR STAIRS, RAMP, EXTERIOR LIGHTING | | OR WOOD DECKING. | | | | STAIR RISERS SHALL BE BETWEEN 4 INCHES AND 7 INCHES IN | | HEIGHT. STAIRS SHALL BE SLIP RESISTANT AND HAVE A | | MINIMUM TREAD DEPTH OF 11 INCHES AND PREVENT THE | | ACCUMULATION OF WATER. GUARDS, AT LEAST 42-INCHES TALL, | | SHALL BE PROVIDED AT THE OPEN SIDES OF MEANS OF EGRESS | | (STAIRS, MEZZANINE, ETC.) THAT EXCEED 30-INCHES ABOVE | | THE FLOOR. OPEN GUARDS SHALL PROHIBIT THE PASSAGE OF A | | 4-INCH DIAMETER SPHERE UP TO A HEIGHT OF 34-INCHES. THE | | TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD AND | | BOTTOM ELEMENT OF THE GUARDRAIL SHALL PROHIBIT THE | | PASSAGE OF A 6-INCH DIAMETER SPHERE. | | | | HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR. | | HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND | | NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD, | | MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE | | LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE | | RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT | | NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A | | DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN | | 2 INCHES. | | | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | | | | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-03-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-03-18 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-03-18 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-04-14 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-03-30 |
Time |
12:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-03-28 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-03-28 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-03-07 |
Time |
15:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-09-24 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2015-09-24 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2015-08-19 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-09-10 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-09-10 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-03-26 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-26 |
Time |
04:19 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-26 |
Time |
04:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-09-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-05 |
Time |
05:57 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-05 |
Time |
05:44 |
Sent To |
|
|
Notes |
2015-09-05 05:56:41 | INDICATE ON THE PLANS HOW THE SEWAGE WILL BE DISPOSED. | | WILL IT GO TO A HOLDING TANK? HOLDING TANKS EXCEEDING | | 300 GALS. REQUIRE AN APPROVAL FOM THE PBC HEALTH DEPT. | | | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-04-14 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-04-14 |
Time |
|
Sent To |
|
|
Notes |
2016-04-01 12:43:10 | HAVE ORIGINAL DOCUMENTS WITH PERMIT APPLICATION TO BE | | REVIEWED |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-03-18 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2016-03-18 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2016-03-18 |
Time |
14:29 |
Sent To |
|
|
Notes |
2016-03-18 14:29:16 | ALL SUCH STRUCTURES, INCLUDING TRAILERS, SHALL BE | | REMOVED WITHIN SEVEN DAYS OF THE FINAL CONSTRUCTION | | INSPECTION BY THE CITY AND PRIOR TO THE ISSUANCE OF A | | CERTIFICATE OF OCCUPANCY. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-09-24 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2015-09-24 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2015-09-24 |
Time |
13:51 |
Sent To |
|
|
Notes |
2015-09-24 13:52:00 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 09.24.2015 | | PERMIT NO.: 15071002 | | ADDRESS: 1451 S. OLIVE AVENUE | | CONTRACTOR/CONTACT: MICHAEL IZZO | | TELEPHONE NO.: 561.236.7052 | | SCOPE OF REVIEW: CONSTRUCTION TRAILERS | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. STAFF HAS SOME CONCERNS REGARDING THE PLACEMENT OF | | THE CONSTRUCTION TRAILERS AND THEIR IMPACT ON THE | | NUMBER OF PARKING SPACES, EXISTING LANDSCAPING IN THE | | PARKING LOT, ETC. I THINK IT WOULD BE MOST BENEFICIAL | | IF THERE WAS A MEETING BETWEEN THE CONTRACTOR, STAFF, | | REPRESENTATIVES OF THE NORTON, ETC. SO THAT THERE IS AN | | UNDERSTANDING OF MANAGEMENT OF THE SITE THROUGHOUT THE | | ENTIRE CONSTRUCTION PROJECT. THINGS TO DISCUSS WOULD BE | | CONSTRUCTION STAGING, PARKING FOR CONSTRUCTION WORKERS, | | PARKING FOR EMPLOYEES, PUBLIC PARKING, ETC. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | | 2015-08-24 11:10:02 | 8/24/15 |
|
|