Plan Review Details - Permit 15070826
Plan Review Stops For Permit 15070826 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-07-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-28 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-28 |
Time |
15:13 |
Sent To |
I |
|
Notes |
2015-07-28 15:34:27 | THOUGH THE RESUB WAS NOT AS REQUIRED, AN ENLARGED VIEW | | OF THE AREA OF WORK WAS SUBMITTED FOR BE INCLUDED WITH | | THE PERMIT DOCUMENTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-07-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-28 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-28 |
Time |
11:09 |
Sent To |
I |
|
Notes |
2015-07-28 11:19:56 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE | | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. | | | | 1. FROM THE DRAWINGS SUBMITTED I CANT IDENTIFY THE | | SCOPE OF WORK. YOU SHALL INDICATE YOUR SCOPE OF WORK ON | | THE DRAWINGS. | | 2. YOU SHALL DESCRIBED HOW YOU INTEND TO COMPLETE THIS | | SCOPE OF WORK, EI: DESCRIBED THE PROPOSED WIRING METHOD | | AND HOW WILL YOU BE GETTING FROM ONE DEVICE TO ANOTHER. | | 3. PROVIDE LITERATURE ON THE PROPOSED EQUIPMENT, MAKING | | SURE THAT IT WILL PERFORM IN A FAIL-SAFE MANNER. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-07-23 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-07-23 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-07-23 |
Time |
10:42 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-28 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-28 |
Time |
14:47 |
Sent To |
|
|
Notes |
2015-07-28 15:41:16 | 7/28/15 - PASSED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED | | VIA EMAIL. SENT TO SMALL READY BIN "K". MA | 2015-07-28 15:13:01 | RESUBMIT OF ELECTRICAL CORRECTIONS | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-07-28 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-28 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-21 |
Time |
11:30 |
Sent To |
|
|
Notes |
2015-07-28 11:24:22 | 7/28/15 - FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN "K". MA | 2015-07-21 11:31:07 | ROUTED TO FIRE |
|
|
|