Plan Review Details - Permit 15070665
Plan Review Stops For Permit 15070665 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-08-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-07 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-07 |
Time |
07:42 |
Sent To |
|
|
Notes |
2015-08-07 07:56:09 | 2ND REVIEW: FBC 2014 5TH ED. | | | | THE COMMENTS BELOW BY SAMANTHA HILL WERE NOT ADDRESSD | | ADEQUATELY IN THE RE-SUBMITTAL | | | | 1. VALUE TO INCLUDE MATERIAL, LABOR, OVERHEAD, PROFIT, | | ENGINEERING, FBC 109. | | | | 2. PROVIDE ENGINEERING FOR PROPOSED SIGN AND FIXTURE, | | FBC 1609. | | | | IN FURTHERANCE: | | | | IT APPEARS THE SUPPLIED CONTRACT IS FOR THE | | INSTALLATION ONLY OF THE POLE AND FIXTURES AND DOES NOT | | INCLUDE THE POLE AND FIXTURE AND THE COST OF | | ENGINEERING WHICH IS YET TO BE PERRFORME. PLEASE NOTE | | THAT THE SOL MANUFACTURER SUPPLIED GENERAL SPEC SHEET | | CONTAINS A WARNING THAT IT IS ONLY A GENERAL GUIDELINE | | AND STRONGLY RECOMMENDS THAT A QUALIFIED PROFESSION, | | WHICH MEANS A FLORIDA LICENSED ENGINEER, PROVIDE | | ENGINEERING ANALYSIS ON THE POLE AND FIXTURES TO BE | | ATTACHER THERETO, THIS MEANS A WIND LOAD ANALYSIS AND | | RECOMMENDED POLE AND ATTACHMENTS, | | | | NEW COMMENT: | | | | BASED UPON THE PLAN PROVIDED, THE POLE LOCATION IS | | BETWEEN 3461 & 3500 COMMODORE CT. THE PERMIT | | APPLICATION INDICATES 3281 COMMODORE CT WHICH IS AT THE | | OTHER END OF THE STREET. PLEASE VERIFY THE PROPOSED | | LOCATION AND CONSULT WITH SANDRA WURAFTIC TO OBTAIN A | | SPECIFIC "@" TYPE OF ADDRESS FOR THE POLE LOCATION. THE | | "@" TYPE IS USED FOR SUCH INSTALLATIONS TO INDICATE A | | NEARBY ACTUAL ADDRESS OF A STRUCTURE. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-08-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-05 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-05 |
Time |
17:22 |
Sent To |
Z |
|
Notes |
2015-08-05 17:24:05 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. VALUE TO INCLUDE MATERIAL, LABOR, OVERHEAD, PROFIT, | | ENGINEERING, FBC 109. | | | | 2. PROVIDE ENGINEERING FOR PROPOSED SIGN AND FIXTURE, | | FBC 1609. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-08-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-07 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-07 |
Time |
07:42 |
Sent To |
|
|
Notes |
2015-08-07 08:11:55 | 1ST REVIEW: FBC 2014 5TH ED./NEC 2011 | | | | NEC 110 - YOU MUST PROVIDE THE LISTING FOR EACH | | COMPONENT, FIXTURE, WHICH YOU DID, BUT ALSO THE | | PV/SOLAR COMPONENT. THE WIND DESIGN MUST TAKE THE | | SPECIFIC FIXTURE AND SOLAR PANEL INTO ACCOUNT AS TO | | EPA. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2015-08-05 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-08-05 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-08-05 |
Time |
13:49 |
Sent To |
B |
|
Notes |
2015-08-05 14:03:37 | THE PROPOSED LIGHT POLE IS SELF SUFFICIENT VIA SOLAR | | POWER, BUT NEEDS A BLDG REVIEW DUE TO THE NATURE OF THE | | PERMIT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-08-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-07 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-06 |
Time |
07:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-08-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-06 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-05 |
Time |
13:49 |
Sent To |
|
|
Notes |
2015-07-16 13:16:54 | ROUTED TO ELEC <5K |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-08-06 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-08-06 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-08-06 |
Time |
16:13 |
Sent To |
B |
|
Notes |
|
|
|