Plan Review Details - Permit 15070609
Plan Review Stops For Permit 15070609 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-08-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-27 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-27 |
Time |
12:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-08-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-10 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-10 |
Time |
11:46 |
Sent To |
|
|
Notes |
2015-08-10 11:47:04 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | COMMENTS FROM PREVIOUS LIST (APPLICATIONS SIGNED BY | | OWNER AND A CONTRACT WAS PROVIDED, BUT REVISED | | ENGINEERING WAS NOT SUBMITTED): | | | | 1. REVISE GOVERNING CODE, FS 553. | | | | 2. REVISE ENGINEERING TO INCLUDE SIGN SIZE, FBC 1609. | | | | 3. FASTENERS SPECIFIED ONE EVERY 48"; PROVIDE | | CALCULATIONS, FBC 1609. | | | | 4. OK | | | | NEW COMMENT: | | | | 5. AFTER THIRD FAILED PLAN REVIEW FOR THE SAME COMMENT, | | A 4X FEE IS REQUIRED TO BE ASSESSED, SEE FS | | 553.80(2)(C). | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-08-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-03 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-03 |
Time |
14:49 |
Sent To |
E |
|
Notes |
2015-08-03 14:51:39 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. REVISE GOVERNING CODE, FS 553. | | | | 2. REVISE ENGINEERING TO INCLUDE SIGN SIZE, FBC 1609. | | | | 3. FASTENERS SPECIFIED ONE EVERY 48"; PROVIDE | | CALCULATIONS, FBC 1609. | | | | 4. PROVIDE A VERIFIABLE COPY OF THE CONTRACT FOR THIS | | JOB, FBC 109. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-08-06 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-08-06 |
Time |
18:56 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-08-06 |
Time |
18:52 |
Sent To |
|
|
Notes |
2015-08-06 18:57:26 | IMPORTANT NOTICE: FOR FINAL ELECTRICAL INSPECTION, | | REGARDLESS IF THIS SIGN WAS CONNECTED TO NEW OR | | EXISTING POWER, FULL COMPLIANCE WITH 2008 NEC & 2010 | | FBC ENERGY CONSERVATION SECTION 505.2.4 WILL BE | | REQUIRED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-08-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-27 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-18 |
Time |
16:00 |
Sent To |
|
|
Notes |
2015-08-18 16:00:57 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-08-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-10 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-07 |
Time |
13:02 |
Sent To |
|
|
Notes |
2015-08-07 13:02:29 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-08-06 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-08-06 |
Time |
18:57 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-15 |
Time |
13:38 |
Sent To |
|
|
Notes |
2015-08-06 18:59:27 | 8/6/15 - PASSED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | NOTIFIED OF STATUS. SENT TO SMALL DENIED BIN "A". MA | 2015-08-03 14:52:09 | 8/3 TO ELEC | | | | | 2015-07-15 13:40:01 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-07-15 |
Time |
15:16 |
Sent To |
B |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |