Plan Review Details - Permit 15070233
Plan Review Stops For Permit 15070233 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-07-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-24 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-24 |
Time |
13:06 |
Sent To |
|
|
Notes |
2015-07-24 13:11:48 | ****PROVISO**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | CONTRACTOR IS TO CIRCLE ALL APPLICABLE DETAILS AND | | ANCHOR SPACING PRIOR TO INSPECTION. | | | | FAILURE TO DO SO MAY RESULT IN REINSPECTION FEES. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-07-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-17 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-17 |
Time |
13:53 |
Sent To |
|
|
Notes |
2015-07-17 14:05:18 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. DESIGN PRESSURES ARE TOO LOW. SEE FBC 5TH EDITION | | RESIDENTIAL TABLE 301.2.2 OR PROVIDE CALCULATIONS FOR | | THE PROPOSED DESIGN PRESSURES. PER THE TABLE, PRESSURES | | SHOULD BE +36.2 / -39.4. | | | | 2. SUBSTRATE IS TYPICALLY CONCRETE TOP, BLOCK OR FILLED | | CELLS BOTTOM. PLEASE ADVISE AS TO HOW IT HAS BEEN | | DETERMINED THAT THERE IS FORMED AND POURED CONCRETE AT | | THE BOTTOM, FBC 107. | | | | 3. INSTALLATION SCHEDULE IS LACKING INFORMATION - | | MOUNTING TYPE, EDGE DISTANCE, SPECIFIC FASTENER (STATES | | "TAPCONS" BUT THERE ARE MORE THAN ONE TAPCON IN THE | | PRODUCT APPROVAL). PLEASE COMPLETE THE EDGE DISTANCE | | AND SPAN COLUMNS, AND CIRCLE THE PROPOSED INSTALLATION | | (SPECIFIC FASTENER AND MOUNTING TYPE) ON THE PRODUCT | | APPROVAL SO PROPOSED INSTALLATION CAN BE REVIEWED. | | THOSE TWO COLUMNS WILL BE COMPLETED FOR YOU IF THE | | INFORMATION IS PROVIDED. | | | | PLEASE BE ADVISED THAT, IF YOU EXPERIENCE DIFFICULTY IN | | COMPLETING THE INSTALLATION SCHEDULE, IF ENOUGH DETAILS | | ARE MARKED ON THE PRODUCT APPROVAL FOR ME TO DETERMINE | | INTENDED INSTALLATION, THE INSTALLATION SCHEDULE WILL | | BE REDLINED FOR YOU. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-24 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-20 |
Time |
09:33 |
Sent To |
|
|
Notes |
2015-07-23 09:33:28 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-07-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-17 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-07 |
Time |
09:04 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy