Plan Review Details - Permit 15070233
Plan Review Stops For Permit 15070233
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-07-24 Cont ID  
Sent By shill Date 2015-07-24 Time 13:06 Rev Time 0.00
Received By shill Date 2015-07-24 Time 13:06 Sent To  
Notes
2015-07-24 13:11:48****PROVISO****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 CONTRACTOR IS TO CIRCLE ALL APPLICABLE DETAILS AND
 ANCHOR SPACING PRIOR TO INSPECTION.
  
 FAILURE TO DO SO MAY RESULT IN REINSPECTION FEES.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-07-17 Cont ID  
Sent By shill Date 2015-07-17 Time 13:53 Rev Time 0.00
Received By shill Date 2015-07-17 Time 13:53 Sent To  
Notes
2015-07-17 14:05:18****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. DESIGN PRESSURES ARE TOO LOW. SEE FBC 5TH EDITION
 RESIDENTIAL TABLE 301.2.2 OR PROVIDE CALCULATIONS FOR
 THE PROPOSED DESIGN PRESSURES. PER THE TABLE, PRESSURES
 SHOULD BE +36.2 / -39.4.
  
 2. SUBSTRATE IS TYPICALLY CONCRETE TOP, BLOCK OR FILLED
 CELLS BOTTOM. PLEASE ADVISE AS TO HOW IT HAS BEEN
 DETERMINED THAT THERE IS FORMED AND POURED CONCRETE AT
 THE BOTTOM, FBC 107.
  
 3. INSTALLATION SCHEDULE IS LACKING INFORMATION -
 MOUNTING TYPE, EDGE DISTANCE, SPECIFIC FASTENER (STATES
 "TAPCONS" BUT THERE ARE MORE THAN ONE TAPCON IN THE
 PRODUCT APPROVAL). PLEASE COMPLETE THE EDGE DISTANCE
 AND SPAN COLUMNS, AND CIRCLE THE PROPOSED INSTALLATION
 (SPECIFIC FASTENER AND MOUNTING TYPE) ON THE PRODUCT
 APPROVAL SO PROPOSED INSTALLATION CAN BE REVIEWED.
 THOSE TWO COLUMNS WILL BE COMPLETED FOR YOU IF THE
 INFORMATION IS PROVIDED.
  
 PLEASE BE ADVISED THAT, IF YOU EXPERIENCE DIFFICULTY IN
 COMPLETING THE INSTALLATION SCHEDULE, IF ENOUGH DETAILS
 ARE MARKED ON THE PRODUCT APPROVAL FOR ME TO DETERMINE
 INTENDED INSTALLATION, THE INSTALLATION SCHEDULE WILL
 BE REDLINED FOR YOU.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-24 Cont ID  
Sent By shill Date 2015-07-24 Time 13:12 Rev Time 0.00
Received By shill Date 2015-07-20 Time 09:33 Sent To  
Notes
2015-07-23 09:33:28RESUB ROUTED TO SHILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-17 Cont ID  
Sent By shill Date 2015-07-17 Time 14:05 Rev Time 0.00
Received By shill Date 2015-07-07 Time 09:04 Sent To  
Notes
***NONE***