Plan Review Stops For Permit 15070144 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2015-09-17 |
|
|
Cont ID |
|
Sent By |
hill |
Date |
2015-09-17 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-09-17 |
Time |
14:04 |
Sent To |
|
|
Notes |
2015-09-17 14:05:18 | PROVISO - PROVIDE FRAMING DETAIL AT INSPECTION | | REVISION MAY BE REQUIRED SUBJECT TO FIELD INSPECTOR'S | | DISCRETION | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-09-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-09-08 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-09-08 |
Time |
09:32 |
Sent To |
|
|
Notes |
2015-09-08 09:36:41 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FROM PREVIOUS LIST: | | | | 1. IT IS NOT CLEAR WHICH PRODUCTS ARE TO BE INCLUDED IN | | THIS PERMIT. COLLATE TWO DISTINCT SETS OF PLANS, MARK | | OLD PAGES AS "VOID" FBC 107. | | | | 3RD REVIEW, BOTH CASEMENT AND SINGLE HUNG WINDOW | | PRODUCT APPROVALS PROVIDED, BUT ONLY SINGLE HUNG SHOWN | | ON THE FLOOR PLAN, FBC 107. | | | | 2. MECHANICAL, ELECTRICAL, PLUMBING, STUCCO, REPAIR | | WORK DONE WITHOUT PERMITS. PLEASE ADVISE WHEN PERMITS | | FOR THESE ITEMS HAVE BEEN APPLIED FOR. | | | | 3. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | FS471. | | | | NEW COMMENT, DISCUSSED WITH CONTRACTOR: | | | | 4. THIS PROPERTY WAS CITED FOR FRAMING WORK WITHOUT A | | PERMIT. DOES THIS FRAMING AFFECT THE WINDOWS PROPOSED? | | IF THE FRAMING WHICH HOLDS THE WINDOWS WAS PART OF THE | | WORK DONE WITHOUT PERMITS, A FRAMING DETAIL SHOULD BE | | PROVIDED. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-08-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-29 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-29 |
Time |
10:11 |
Sent To |
|
|
Notes |
2015-08-29 10:14:06 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | FAC9N-3, FBC 5TH EDITION 301. | | | | FOR FLORIDA STATE PRODUCT APPROVAL, PROVIDE THE | | FOLLOWING FOR EACH PRODUCT: | | | | COVER SHEET (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE | | THE CODE VERSION, PRODUCT APPROVAL NUMBER, STATUS, | | GENERAL INFORMATION ABOUT THE PRODUCT) | | EVALUATION REPORT | | INSTALLATION INSTRUCTIONS | | | | 2. FLOOR PLAN APPEARS COMPLIANT BUT IS TOO SMALL TO BE | | LEGIBLE. PROVIDE LEGIBLE PLANS, FBC 107. | | | | 3. IT IS NOT CLEAR WHICH PRODUCTS ARE TO BE INCLUDED IN | | THIS PERMIT. COLLATE TWO DISTINCT SETS OF PLANS, MARK | | OLD PAGES AS "VOID" FBC 107. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-07-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-29 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-29 |
Time |
07:31 |
Sent To |
|
|
Notes |
2015-07-29 07:32:44 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | FAC9N-3, FBC 5TH EDITION 301. | | | | FOR FLORIDA STATE PRODUCT APPROVAL, PROVIDE THE | | FOLLOWING FOR EACH PRODUCT: | | | | COVER SHEET (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE | | THE CODE VERSION, PRODUCT APPROVAL NUMBER, STATUS, | | GENERAL INFORMATION ABOUT THE PRODUCT) | | EVALUATION REPORT | | INSTALLATION INSTRUCTIONS | | | | 2. REVISE THE FLOOR PLAN TO INCLUDE ROOM DESIGNATIONS. | | | | 3. IF ANY BEDROOM WINDOWS ARE LESS THAN 51" IN HEIGHT, | | REVISSE PLAN TO STATE THE TYPE OF EXIST WINDOW AND | | CLEAR OPENING SIZE, FBC R310, FBC EB 704.1. THE CLEAR | | OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT: | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | - AWNING, CASEMENT, SINGLE HUNG? | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | WINDOW IS FULLY OPEN. | | | | STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE. | | THIS CAN BE OBTAINED FROM THE MANUFACTURER. | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
P |
Date |
2015-09-17 |
|
|
Cont ID |
|
Sent By |
mittner |
Date |
2015-09-17 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-09-17 |
Time |
12:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2015-09-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-09-04 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-09-04 |
Time |
09:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-08-26 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-08-26 |
Time |
13:59 |
Sent To |
|
|
Notes |
2015-08-26 14:00:09 | ALL APPROVED EXCEPT FOR OVAL GLASS DOOR IMAGE |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2015-08-06 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-08-06 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-08-06 |
Time |
14:56 |
Sent To |
|
|
Notes |
2015-08-06 14:57:24 | VINYL WINDOWS NOT PERMITTED IN HISTORIC DISTRICT. ALSO | | NOT ENOUGH EXPLANAITION OF WINDOW STYLE, FRAME COLOR, | | GRID PATTERN, GLASS COLOR. QUESTIONS CONTACT FRIEDERIKE | | MITTNER AT 822-1457. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-09-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-09-17 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-09-09 |
Time |
10:36 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-09-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-09-08 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-09-02 |
Time |
09:33 |
Sent To |
|
|
Notes |
2015-09-02 09:33:36 | RESUB ROUTED TO FMITTNER VIA SGRAHAM'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-08-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-29 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-21 |
Time |
13:00 |
Sent To |
|
|
Notes |
2015-08-21 13:00:24 | RESUB ROUTED TO FMITTNER VIA SGRAHAM'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-08-21 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-08-06 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-07-06 |
Time |
10:01 |
Sent To |
|
|
Notes |
2015-07-29 07:33:07 | 7/29 TO S PALMER DESK TO COORDINATE HISTORIC REVIEW | | | | | 2015-07-06 10:01:52 | ROUTED TO MISC 1 |
|
|