Plan Review Stops For Permit 15061278 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-10-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-26 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-26 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-04-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-04-06 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-04-06 |
Time |
08:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-02-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-02-18 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-02-18 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-07-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-07-27 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-07-27 |
Time |
09:40 |
Sent To |
|
|
Notes |
2015-07-27 11:41:26 | BUILDING PLAN REVIEW | | W. P. B. PERMIT:15061278 | | ADD: 777 S. FLAGLER DR. FLOORS: 11TH & 12TH | | CONT: WOOLEMS INC. | | TEL: (561)835-0401 | | E-MAIL: [email protected] | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MON. JULY 27/ 2015 | | ACTION: DENIED | | | | 1) THE PERMIT APPLICATION WILL NEED TO INCLUDE UNDER | | THE DESCRIPTION OF WORK THE 11TH FLOOR AS WELL AS THE | | 12TH FLOOR. 107,2,1,3 ADDITIONAL INFORMATION IS | | REQUIRED. | | | | 2) SHEET 008-A0.07 THE 11TH FLOOR AT GRID LINE F-H & 8 | | THE SET OF HORIZONTAL SLIDING DOORS FROM THE ELEVATOR | | LOBBY TO RECEPTION AREA WILL NEED TO SHOW COMPLIANCE | | WITH: 2010 FBC-B 1008.1.4.3 PLEASE ALSO BE AWARE OF | | 1008.1.10 PANIC HARDWARE FOR ASSEMBLY OCCUPANCIES. IF | | THIS DOOR IS TO HAVE ACCESS-CONTROLLED EGRESS THEN | | 1008.1.4.4 WILL ALSO BE REQUIRED. | | | | 3) SHEET 001-A1.03 FLOOR LEVEL 11 BREAKROOM 1113 THE | | BREAKROOM IS APPROXIMATELY 900 SQ. FT. WHICH WILL HAVE | | A OCCUPANT LOAD OF 50 OR GREATER. 2010 FBC-B TABLE | | 1004.1.1 900 SQ. FT./ 15 = 60 OCCUPANTS. PLEASE SEE | | DOORS 1113A THEY SWING INTO THE ROOM. THE 2010 FBC-B | | SECTION 1008.1.2 REQUIRES DOORS TO SWING IN THE | | DIRECTION OF EGRESS TRAVEL WHENEVER THE OCCUPANT LOAD | | OF 50 OR MORE. | | | | 4) SHEET 011-A1.03 PLEASE PROVIDE THE TOTAL SQ. FT. OF | | AREA FOR THE TENANT SPACE THIS FLOOR AND ALSO PROVIDE | | THE SQ. FOOTAGE FOR ROOMS 1113 THE BREAKROOM, | | CONFERENCE ROOM 1102 & CONFERENCE ROOM 1103 . IF THEY | | ARE OVER 10 % OF THE TENANT SPACE FLOOR AREA THIS WILL | | BE CONSIDERED A MIXED OCCUPANCY FLOOR. THE DESIGNER OF | | RECORD WILL NEED TO DECLARE THEN IF IT IS A SEPERATED | | OCCUPANCY OR NON-SEPARATED OCCUPNCY. SEE FBC-B 508.2.4 | | VERSES 508.3. | | | | 5) SHEET 011-A1.03 BOTH 2 HR RATED EXITS FAIL TO SHOW | | THE 1 1/2 HR. FIRE RATED DOOR ON THE EXIT ENCLOSURE. | | 2010 FBC-B TABLE 715.4. | | | | 6) SHEET 011-A1.03 SHOWS A SPIRAL STAIR FROM THE 11TH | | FLOOR TO THE 12TH FLOOR. PLEASE PROVIDE A CUT SECTION | | THROUGH THIS AREA PROVIDING DETAILS WITH 2010 FBC-B | | 708.2 EXCEPTION 2.1 THE REQUIRED DRAFT CURTAIN AND | | CLOSELY SPACED FIRE SPRINKLERS. | | | | 7) SHEET 011-A1.03 PLEASE PROVIDE SPECIFICATIONS FOR | | THE SPIRAL STAIRCASE SIZE OF STAIRS, HEIGHT OF STAIRS, | | HANRAIL AND GAURD-RAIL REQUIREMENTS. | | 2010 FBC-B 1009.9, 1012 & 1013. | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | 6) | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2016-07-12 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-07-12 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-07-12 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2016-04-12 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-04-12 |
Time |
20:16 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-04-04 |
Time |
18:47 |
Sent To |
|
|
Notes |
2016-04-12 20:18:19 | I AM WILLING TO ISSUE A PROVISO FOR THE ONLY ITEMS I | | SEE LACKING WHICH IS THE CONFERENCE ROOM D-F/13-10 IS | | MISSING EMERGENCY AND EXIT LIGHTING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-02-29 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-02-29 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-02-29 |
Time |
13:05 |
Sent To |
|
|
Notes |
2016-02-29 16:03:15 | SEE ATTACHED | | 2ND ELECTRICAL REVIEW NOTES FOR REVISION #:15061278 | | REVIEWED FOR COMPLIANCE WITH: | | FBC 2010 EDITION | | NFPA 70 2008 (NEC) | | | | CORRECTIONS REQUIRED: | | SHEET E1.01 | | 1. NOW THAT THE SHEET IS EASIER TO READ AND INTERPRET I | | FIND THE NEED FOR ADDITIONAL EMERGENCY ILLUMINATION IN | | THE VESTIBULE IN THE MEN?S AND WOMEN?S LOCKER ROOM. | | 2. IN THE SAME AREA A DIRECTIONAL EXIT LIGHT IS MISSING | | POINTING TOWARDS THE DOORWAY. | | 3. EXIT LIGHT REQUIRED AT THE MEN?S & WOMEN?S RESTROOM. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-07-06 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-06 |
Time |
20:27 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-06 |
Time |
19:06 |
Sent To |
|
|
Notes |
2015-07-06 20:28:13 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | EXAMINER WAS UNABLE TO COMPLETE THE REVIEW OF THE ABOVE | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | THE CORRECTIONS NOTED. | | | | THE FOLLOWING ITEMS SHALL BE CORRECTED AND THE PLANS | | RESUBMITTED FOR A SECOND REVIEW: | | | | 1. SEPARATE PERMIT REQUIRED FOR FIRE ALARM | | INSTALLATION. THEREFORE DO NOT INCLUDE THE FIRE ALARM | | DEVICES ON THIS SHEET. | | 2. THESE PAGES ARE TOO CLUTTERED TO PROPERLY IDENTIFY | | THE DIFFERENT ROOMS. PROVIDE A SEPARATE SHEET FOR THE | | REFLECTED CEILING. | | 3. EMERGENCY STAIRS NEED TO BE IDENTIFIED TO ASCERTAIN | | PROPER LOCATION OF EXIT LIGHTING. | | 4. EMERGENCY LIGHTING IS NOT CLEARLY INDICATED | | ACCORDING TO THE LEGEND. | | 5. IN THE 12TH FLR. INDICATE THE AREA DIRECTLY ADJACENT | | TO YOUR SCOPE OF WORK WITH RESPECT TO THE EXITS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2016-02-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-02-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-02-24 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2015-08-12 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-08-12 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-08-12 |
Time |
12:26 |
Sent To |
|
|
Notes |
2015-08-12 12:51:18 | 777 SOUTH FLAGLER DRIVE - 11TH/12TH FLOOR | | PERMIT #15061278 | | REFER TO THE FOLLOWING PERMITS TO FULLY UNDERSTAND THE | | DESIGN: | | PERMIT #15061278 (11TH - 12TH FLOORS) | | PERMIT #15071149 (12TH, 14TH, 15TH FLOORS; NOTE NO 13TH | | FLOOR) | | MASTER #14060196 | | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE CIRCULAR MONUMENTAL STAIR HAS BEEN REDESIGNED TO | | SERVE THREE FLOORS (11TH, 12TH & 14TH FLOOR - NO 13TH | | FLOOR); THEREFORE, THE OPEN STAIR DESIGN WILL NEED TO | | COMPLY WITH NFPA 101 SECTION 8.6 "VERTICAL OPENINGS" AS | | AN "ATRIUM" (SECTION 8.6.7). NOTE: THE OPEN STAIR WAS | | PREVIOUSLY DESIGNED AND PERMITTED AS A 2-STORY | | "CONVENIENCE OPENING." | | | | SECTION 8.6.7 | | (1) THE ATRIUM IS SEPARATED FROM THE ADJACENT SPACES BY | | FIRE BARRIERS WITH NOT LESS THAN A 1-HOUR FIRE | | RESISTANCE RATING, WITH OPENING PROTECTIVES FOR | | CORRIDOR WALLS, UNLESS ONE OF THE FOLLOWING IS MET: | | (A) THE REQUIREMENT OF 8.6.7(1) SHALL NOT APPLY TO | | EXISTING, PREVIOUSLY APPROVED ATRIUMS. | | (B) ANY NUMBER OF LEVELS OF THE BUILDING SHALL BE | | PERMITTED TO OPEN DIRECTLY TO THE ATRIUM WITHOUT | | ENCLOSURE, BASED ON THE RESULTS OF THE ENGINEERING | | ANALYSIS REQUIRED IN 8.6.7(5). | | (C) GLASS WALLS AND INOPERABLE WINDOWS SHALL BE | | PERMITTED IN LIEU OF THE FIRE BARRIERS WHERE ALL THE | | FOLLOWING ARE MET: | | I. AUTOMATIC SPRINKLERS ARE SPACED ALONG BOTH SIDES OF | | THE GLASS WALL AND THE INOPERABLE WINDOWS AT INTERVALS | | NOT TO EXCEED 6 FT (1830 MM). | | II. THE AUTOMATIC SPRINKLERS SPECIFIED IN | | 8.6.7(1)(C)(I) ARE LOCATED AT A DISTANCE FROM THE GLASS | | WALL NOT TO EXCEED 12 IN. (305 MM) AND ARRANGED SO THAT | | THE ENTIRE SURFACE OF THE GLASS IS WET UPON OPERATION | | OF THE SPRINKLERS. | | III. THE GLASS WALL IS OF TEMPERED, WIRED, OR LAMINATED | | GLASS HELD IN PLACE BY A GASKET SYSTEM THAT ALLOWS THE | | GLASS FRAMING SYSTEM TO DEFLECT WITHOUT BREAKING | | (LOADING) THE GLASS BEFORE THE SPRINKLERS OPERATE. | | IV. THE AUTOMATIC SPRINKLERS REQUIRED BY 8.6.7(1)(C)(I) | | ARE NOT REQUIRED ON THE ATRIUM SIDE OF THE GLASS WALL | | AND THE INOPERABLE WINDOW WHERE THERE IS NO WALKWAY OR | | OTHER FLOOR AREA ON THE ATRIUM SIDE ABOVE THE MAIN | | FLOOR LEVEL. | | V. DOORS IN THE GLASS WALLS ARE OF GLASS OR OTHER | | MATERIAL THAT RESISTS THE PASSAGE OF SMOKE. | | VI. DOORS IN THE GLASS WALLS ARE SELF-CLOSING OR | | AUTOMATIC-CLOSING UPON DETECTION OF SMOKE. | | VII. THE GLASS IS CONTINUOUS VERTICALLY, WITHOUT | | HORIZONTAL MULLIONS, WINDOW TREATMENTS, OR OTHER | | OBSTRUCTIONS THAT WOULD INTERFERE WITH THE WETTING OF | | THE ENTIRE GLASS SURFACE. | | (2) ACCESS TO EXITS IS PERMITTED TO BE WITHIN THE | | ATRIUM, AND EXIT DISCHARGE IN ACCORDANCE WITH 7.7.2 IS | | PERMITTED TO BE WITHIN THE ATRIUM. | | (3) THE OCCUPANCY WITHIN THE ATRIUM MEETS THE | | SPECIFICATIONS FOR CLASSIFICATION AS LOW OR ORDINARY | | HAZARD CONTENTS. (SEE 6.2.2.) | | (4) THE ENTIRE BUILDING IS PROTECTED THROUGHOUT BY AN | | APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN | | ACCORDANCE WITH SECTION 9.7. | | (5) AN ENGINEERING ANALYSIS IS PERFORMED THAT | | DEMONSTRATES THAT THE BUILDING IS DESIGNED TO KEEP THE | | SMOKE LAYER INTERFACE ABOVE THE HIGHEST UNPROTECTED | | OPENING TO ADJOINING SPACES, OR 6 FT (1830 MM) ABOVE | | THE HIGHEST FLOOR LEVEL OF EXIT ACCESS OPEN TO THE | | ATRIUM, FOR A PERIOD EQUAL TO 1.5 TIMES THE CALCULATED | | EGRESS TIME OR 20 MINUTES, WHICHEVER IS GREATER. | | (6) WHERE AN ENGINEERED SMOKE CONTROL SYSTEM IS | | INSTALLED TO MEET THE REQUIREMENTS OF 8.6.7(5), THE | | SYSTEM IS INDEPENDENTLY ACTIVATED BY EACH OF THE | | FOLLOWING: | | (A) REQUIRED AUTOMATIC SPRINKLER SYSTEM | | (B) MANUAL CONTROLS | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | | | | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-07-06 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2015-07-06 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2015-07-06 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2016-11-02 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-11-02 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-10-18 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-08-15 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-08-15 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-06-22 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-04-19 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-04-19 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-04-01 |
Time |
14:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-02-29 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-02-29 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-02-10 |
Time |
15:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-07-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-07-27 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-30 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-04-05 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-05 |
Time |
16:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-02-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-02-25 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-02-25 |
Time |
15:31 |
Sent To |
|
|
Notes |
2016-02-25 15:52:45 | 2ND REVIEW: FBC 2014 MECHANICAL | | PERMIT #15061278 | | 2/25/16 | | | | 1) 2ND REQUEST FOR AC COOLING AND HEATING CALCULATIONS | | FOR THE NEW AHU/CU 11-20. | | 2) SHEET M4.01: THE VENTILATION CALCULATIONS FOR THE | | LAUNDRY ROOMS IS NOT IN COMPLIANCE WITH TABLE 403.3. | | PLEASE REVIEW THE TABLE AND REVISE THE CALCULATIONS | | ACCORDINGLY. | | 3) THE RESPONSE NARRATIVE FROM RGD CONSUILTING | | ENGINEERS IS INDICATING THAT THE SCOPE OF WORK FOR THE | | 12TH FLOOR "HAS BEEN REMOVED FROM THE PROJECT", HOWEVER | | THE 12TH FLOOR PLAN SHEETS ARE STILL INCLUDED IN THE | | PLAN SETS. PLEASE CONTACT PLAN REVIEW LIBRARIAN | | CAROLINE PUELL OR LAURA MARCHANT AND HAVE ALL 12TH | | FLOOR PLAN SHEETS REMOVED. | | 4) M2.02: THE EXHAUST GRILL IN THE WOMEN'S TOILET ROOM | | IS MISLABELED AS A SUPPLY DIFFUSER. | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE DRYERS | | WITH AN APPROVAL SIGNATURE FROM THE ENGINEER OF RECORD. | | 6) SUBMIT TWO COPIES OF THE NOA FOR THE ROOF STAND WITH | | AN APPROVAL SIGNATURE FROM THE ENGINEER OF RECORD. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-07-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-07-14 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-07-14 |
Time |
12:45 |
Sent To |
|
|
Notes |
2015-07-14 14:33:52 | 1ST REVIEW: FBC 2010 MECHANICAL | | PERMIT #15061278 | | 7/14/15 | | | | 1) PROVIDE COOLING AND HEATING LOAD CALCULATIONS FOR | | THE NEW AHU/CU 11-20 SYSTEM IN ACCORDANCE WITH ACCA | | MANUAL N OR THE ACCA/ASHRAE STANDARD 183- REFERENCE | | SECTION 503.2.1 FBC-10 ENERGY CONSERVATION. | | 2) IN ACCORDANCE WITH SECTION 709.1 FBC-10 EXISTING | | BUILDING, PROVIDE MINIMUM VENTILATION CALCULATIONS FOR | | THE RECONGFIGURED ROOMS AND SPACES ON THE 11TH AND 12TH | | FLOORS- REFERENCE TABLE 403.3 FBC-10 MECHANICAL. | | PROVIDE A SCHEDULE ON THE PLAN INDICATING THE MINIMUM | | REQUIRED CFM'S OF O/A OR EXHAUST, AND THE CFM'S | | PROVIDED. REFERENCE SECTIONS 503.4.5.1 AND 503.4.5.2 | | FBC-10 ENERGY CONSERVATION, AND ADD NOTES ON SHEET M6.1 | | TO INDICATE VAV TERMINAL DEVICE COMPLIANCES REGARDING | | O/A. | | 3) NEW FIRE DAMPERS ARE SHOWN ON THE PLANS: PROVIDE AN | | EQUIPMENT SCHEDULE ON THE PLAN LISTING THE MAKES AND | | MODELS, FIRE-RESISTANCE RATINGS, AND HOW THEY WILL BE | | ACTUATED- PROVIDE A SEQUENCE OF OPERATION, AND CLARIFY | | IF ANY OTHER ALTERATIONS TO THE SMOKE CONTROL SYSTEM | | ARE PROPOSED. | | 4) THE 12TH FLOOR PLAN LAYOUT ON THE ARCHITECTURAL | | DEMOLITION SHEET (A1.02) DOES NOT MATCH THE LAYOUT | | SHOWN ON THE MECHANICAL DEMO SHEET (M2.0). | | 5) SHEET M2.02: EXHAUST VENTILATION FOR THE TOILET | | ROOMS IS REQUIRED. PLEASE PROVIDE THE DETAILS, EXHAUST | | DUCT RUNS, AND EXHAUST FAN SCHEDULES ON THE PLANS- | | TABLE 403.3 FBC-10 MECHANICAL. | | 6) M2.04: EXHAUST VENTILATION FOR THE LOCKER/TOILET | | ROOMS IS REQUIRED. PROVIDE THE DETAILS, DUCT RUNS, AND | | FAN SCHEDULES ON THE PLAN. | | 7) M2.02 & M2.04 PROVIDE MAKE-UP AIR FOR THE DRYERS- | | REFERENCE SECTION 504.5 FBC-10 MECHANICAL. NOTE THERE | | IS A DUCT DROP SHOWN AT THE FRONT OF THE 12TH FLOOR | | DRYER CLOSET, HOWEVER DOOR 1117 ENCLOSING THE CLOSET IS | | NOT LISTED AS A LOUVERED DOOR ON THE SCHEDULE ON SHEET | | A6.01. PROVIDE THE TOTAL LENGTHS OF THE DRYER EXHAUST | | DUCT RUNS IN COMPLIANCE WITH SECTION 504.6.4, AND | | SUBMIT PRODUCT DATA CUTSHEETS FOR THE APPLIANCES. | | 8) M5.02: THE DESIGN PROFESSIONAL OF RECORD SHALL | | CERTIFY THAT THE CU WILL BE INSTALLED TO WITHSTAND 170 | | MPH WIND LOADS AND PRESSURES- REFERENCE 301.12 FBC-10 | | MECHANICAL. PROVIDE NOTES ON THE PLAN INDICATING | | COMPLIANCE. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2016-11-02 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-02 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-02 |
Time |
16:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2016-08-14 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-08-14 |
Time |
04:42 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-08-14 |
Time |
04:06 |
Sent To |
|
|
Notes |
2016-08-14 04:21:31 | 1) SINCE THIS IS THE THIRD TIME THE PLANS HAVE BEEN | | REJECTED FOR THE SAME COMMENT REGARDING THE DRINKING | | FOUNTAIN, THE NEXT PLAN REVIEW SUBMITTAL IS SUBJECT TO | | BEING CHARGED 4 TIMES THE PLAN REVIEW FEE IN ACCORDANCE | | WITH FL. STATUTE 553.80. | | 2) DRINKING FOUNTAINS ARE REQUIRED IN THE 11TH FLOOR | | SPACE PER 2010 FL. PLUMBING CODE TABLE 403.1. A MINIMUM | | OF 2 DRINKING FOUNTAINS ARE REQD. PER SEC. 211.2 OF THE | | 2010 FAC AND FPC TABLE 403.1 FOOTNOTE (E). 3RD REQUEST. | | THE RESPONSE REGARDING ACCESS TO DRINKING WATER IN THE | | BREAK ROOM AND BUSINESS CENTER DOES NOT COMPLY WITH THE | | CODES. THE DRINKING FOUNTAIN FIXTURE IS REQUIRED IN THE | | NUMBER MANDATED BY THE CODE SECTIONS. SUBMIT REVISED | | SANITARY AND WATER RISERS THAT SHOW THESE FIXTURES. | | 3) GRAB BARS IN THE ACCESSIBLE SHOWERS SHALL COMPLY | | WITH THE 2010 FAC SEC.609. SHT. SK 1.0 SHOWS THE GRAB | | BARS MEASURED TO THE CENTERLINE OF THE BAR. GRAB BARS | | SHALL BE MEASURED TO THE TOP OF THE GRIPPING SURFACE | | FROM THE FINISH FLOOR IN ACCORDANCE WITH THE 2010 FAC | | SEC. 609. | | 4) SHT. SK 1.0 SHALL BEAR THE DIGITAL SIGNATURE AND | | SEAL OF THE DESIGN PROFESSIONAL OF RECORD IN ACCORDANCE | | WITH THE F.A.C. RULE 61G1-16.001, 61G1-16.005. THIS WAS | | OVERLOOKED IN THE PREVIOUS REVIEW. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805 PLUMBING PLAN REVIEW | | -6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2016-04-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-04-19 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-04-19 |
Time |
05:29 |
Sent To |
|
|
Notes |
2016-04-19 09:21:50 | 1) DRINKING FOUNTAINS ARE REQUIRED IN THE 11TH FLOOR | | SPACE PER 2010 FL. PLUMBING CODE TABLE 403.1. A MINIMUM | | OF 2 DRINKING FOUNTAINS ARE REQD. PER SEC. 211.2 OF THE | | 2010 FAC AND FPC TABLE 403.1 FOOTNOTE (E). 2ND REQUEST. | | THE RESPONSE REGARDING ACCESS TO DRINKING WATER IN THE | | BREAK ROOM AND BUSINESS CENTER DOES NOT COMPLY WITH THE | | CODES. THE DRINKING FOUNTAIN FIXTURE IS REQUIRED IN THE | | NUMBER MANDATED BY THE CODE SECTIONS. SUBMIT REVISED | | SANITARY AND WATER RISERS THAT SHOW THESE FIXTURES. | | 2) TOILET ROOM #1152 - THE DOOR SWINGS INTO THE CLEAR | | FLOOR SPACE FOR THE LAVATORY. DOORS SHALL NOT SWING | | INTO THE CLEAR FLOOR SPACE FOR THE LAVATORY PER THE | | 2010 FBC-ACCESSIBILITY SEC.603.2.3.( SEE EXCEPTION | | #2).2ND REQUEST. | | 3) SHOW THE INSIDE CLEAR LENGTH AND WIDTH OF THE | | SHOWERS ON SHEET SK-1.0. COMPLY WITH SEC. 417.4 OF 2010 | | FPC AND SEC. 608 OF THE 2010 FAC. | | 4) THE SHOWER CONTROLS SHALL COMPLY WITH THE 2010 FAC | | SEC.608.5. SUBMIT DETAILS.FBC 107.1. | | 5) GRAB BARS IN THE ACCESSIBLE SHOWERS SHALL COMPLY | | WITH THE 2010 FAC SEC.609. PROVIDE DETAILS. CLEARLY | | INDICATE THE ACCESSIBLE SHOWER ON THE PLANS OR ARE THEY | | ALL ACCESSIBLE? CLARIFY. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-02-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-02-20 |
Time |
06:00 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-02-20 |
Time |
04:43 |
Sent To |
|
|
Notes |
2016-02-20 05:34:23 | 1) THE RESPONSE NARRATIVE STATES THAT THE 12TH FLOOR | | HAS BEEN REMOVED FROM THE SCOPE OF WORK BUT THERE ARE | | STILL PLANS FOR THE 12TH FLOOR BUILDOUT INCLUDED IN | | THIS SUBMITTAL. CLARIFY. | | 2) SHT.005-A0.4 - MOUNTING HEIGHTS- THE HEIGHT OF THE | | GRAB BARS SHALL BE MEASURED FROM THE FINISH FLOOR TO | | THE TOP OF THE GRIPPING SURFACE PER THE 2010 | | FBC-ACCESSIBILITY SEC. 609.4. | | 3) SUBMIT THE OCCUPANT LOAD FOR THE 11TH LEVEL IN | | ACCCORDANCE WITH 2010 FBC-BUILDING, TABLE 1004.1.1. | | 4) WASHING MACHINES AND CLOTHES DRYERS SHALL COMPLY | | WITH THE 2010 FBC-ACCESSIBILITY, SECS.611.1 THROUGH | | 611.4. A CLEAR FLOOR SPACE POSITIONED FOR A PARALLEL | | APPROACH SHALL BE PROVIDED. THE CLEAR FLOOR SPACE SHALL | | BE CENTERED ON THE APPLIANCE. | | 5) BREAK ROOM SINKS AND SINKS IN THE BUSINESS CENTER | | ROOMS SHALL COMPLY WITH 2010 FBC-ACCESSIBILITY | | SECS.212.1, 606. | | 6) SUBMIT ENLARGED TOILET ROOM PLANS SHOWING THE INSIDE | | CLEAR DIMENSIONS OF THE TOILET ROOMS. IF THE WATER | | CLOSET AND LAVATORY ARE LOCATED ON THE SAME WALL THE | | MINIMUM WIDTH SHALL BE 85 INCHES IF BUILT PERFECT. 86 | | INCHES ALLOWS FOR TOLERANCES. | | 7) SHOW THE INSIDE CLEAR DIMENSIONS OF THE SHOWERS & | | TOILET COMPARTMENTSL ON SHT.012 A1.03. COMPLY WITH 2010 | | FBC-ACCESSIBILITY & PLUMBING VOLUMES. | | 8) 2010 FBC -ACCESSIBILITY SEC.213.3.1 - WHERE TOILET | | COMPARTMENTS ARE PROVIDED, AT LEAST ONE SHALL COMPLY | | WITH SEC.604.8.1. | | 9) WHERE LAVATORIES ARE PROVIDED AT LEAST ONEE SHALL | | COMPLY W/FBC-ACCESSIBILITY SEC.606, 213.3.4. | | 10) DRINKING FOUNTAINS ARE REQUIRED IN THE 11TH FLOOR | | SPACE PER 2010 FL. PLUMBING CODE. A MINIMUM OF 2 | | DRINKING FOUNTAINS ARE REQD. PER SEC. 211.2 OF THE 2010 | | FAC. | | 11) TOILET ROOM #1152 - THE DOOR SHALL NOT SWING INTO | | THE CLEAR FLOOR SPACE FOR THE LAVATORY PER THE 2010 | | FBC-ACCESSIBILITY SEC.603.2.3. | | 12) CLEANOUTS ARE REQUIRED IN STACKS PER 2010 FPC | | SEC.708.3.4. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-07-25 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-07-25 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-07-25 |
Time |
06:07 |
Sent To |
|
|
Notes |
2015-07-25 09:44:02 | 1) SHT.005-A0.4 - MOUNTING HEIGHTS- THE HEIGHT OF THE | | GRAB BARS SHALL BE MEASURED FROM THE FINISH FLOOR TO | | THE TOP OF THE GRIPPING SURFACE PER THE 2010 | | FBC-ACCESSIBILITY SEC. 609.4. | | 2) SUBMIT THE OCCUPANT LOAD FOR EACH LEVEL IN | | ACCCORDANCE WITH 2010 FBC-BUILDING, TABLE 1004.1.1. | | 3) WASHING MACHINES AND CLOTHES DRYERS SHALL COMPLY | | WITH THE 2010 FBC-ACCESSIBILITY, SECS.611.1 THROUGH | | 611.4. A CLEAR FLOOR SPACE POSITIONED FOR A PARALLEL | | APPROACH SHALL BE PROVIDED. THE CLEAR FLOOR SPACE SHALL | | BE CENTERED ON THE APPLIANCE. | | 4) BREAK ROOM SINKS AND SINKS IN THE BUSINESS CENTER | | ROOMS SHALL COMPLY WITH 2010 FBC-ACCESSIBILITY | | SECS.212.1, 606. | | 5) SUBMIT ENLARGED TOILET ROOM PLANS SHOWING THE INSIDE | | CLEAR DIMENSIONS OF THE TOILET ROOMS. IF THE WATER | | CLOSET AND LAVATORY ARE LOCATED ON THE SAME WALL THE | | MINIMUM WIDTH SHALL BE 85 INCHES IF BUILT PERFECT. 86 | | INCHES ALLOWS FOR TOLERANCES. | | 6) SHT.012A1.04 - ROOMS 1212 & 1213 - A CLEARANCE OF 36 | | INCHES WIDE MINIMUM BY 48 INCHES LONG MINIMUM MEASURED | | FROM THE CONTROL WALL SHALL BE PROVIDED PARALLEL TO THE | | SHOWER ENTRANCES PER THE 2010 FBC-ACCESSIBILITY, | | SEC.608.2.1. THE PLANS DO NOT SHOW THE CLEARANCE. | | 7) SHOW THE INSIDE CLEAR DIMENSIONS OF THE SHOWERS, | | TOILET COMPARTMENTS, & URINAL STALL ON SHT.012 A1.04. | | COMPLY WITH 2010 FBC-ACCESSIBILITY & PLUMBING VOLUMES. | | 8) 2010 FBC -ACCESSIBILITY SEC.213.3.1 - WHERE TOILET | | COMPARTMENTS ARE PROVIDED, AT LEAST ONE SHALL COMPLY | | WITH SEC.604.8.1. | | 9) WHERE LAVATORIES ARE PROVIDED AT LEAST ONEE SHALL | | COMPLY W/FBC-ACCESSIBILITY SEC.606, 213.3.4. | | 10) DRINKING FOUNTAINS ARE REQUIRED IN THE 11TH AND | | 12TH FLOOR SPACES PER 2010 FL. PLUMBING CODE. A MINIMUM | | OF 2 DRINKING FOUNTAINS ARE REQD. ON EACH FLOOR PER | | SEC. 211.2 OF THE 2010 FAC. | | 11) TOILET ROOM #1152 - THE DOOR SHALL NOT SWING INTO | | THE CLEAR FLOOR SPACE FOR THE LAVATORY PER THE 2010 | | FBC-ACCESSIBILITY SEC.603.2.3. | | 12) SHTS.070 P5.11 & 071 P5.12 - THE STACKS FOR THE | | WASHING MACHINES SHALL BE A MINIMUM OF 3" PER THE 2010 | | FPC SEC.406.3. | | 13) BRANCH VENTS EXCEEDING 40 FEET IN DEVELOPED LENGTH | | SHALL BE INCREASED ONE PIPE SIZE FOR THE ENTIRE | | DEVELOPED LENGTH OF THE VENT PIPE PER 2010 FPC | | SEC.916.4.1.(SEE VENTS FOR TOILET ROOMS IN LOCKERS ON | | LEVEL 12). | | 14) CLEANOUTS ARE REQUIRED IN STACKS PER 2010 FPC | | SEC.708.3.4. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-11-28 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-11-22 |
Time |
12:36 |
Sent To |
|
|
Notes |
2016-11-28 08:09:43 | DIGITAL PLAN REVIEW/ SIGNATURES | | W. P. B. PERMIT: 15061278 | | ADD: 777 S. FLAGLER DR. FLOORS: 11TH & 12TH | | CONT: WOOLEMS INC. | | TEL: (561)835-0401 | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 1ST REVIEW/ SIGNATURES | | DATE: MON. NOV. 28/ 2016 | | ACTION: DENIED | | | | REVIEW FOR DIGITAL SIGNATURES: | | 1) PAPER PLANS SUBMITTED SHEET A0.06 INDICATES REV. # 3 | | WHEREAS THE DIGITAL PLAN DOES NOT HAVE REVISION # 3. | | | | 2) DIGITAL PLANS ARE MISSING SHEET A1.02 | | | | 3) DIGITAL PLANS ARE MISSING SHEET A1.04 | | | | 4) DIGITAL PLANS ARE MISSING SHEET A1.06 | | | | 5) DIGITAL PLANS ARE MISSING SHEET A1.08 | | | | 6) THE DIGITAL PLANS FOR FIRE SPRINKLER, ELECTRICAL, | | MECHANICAL & PLUMBING SHEETS ARE NOT DIGITALLY SIGNED | | NOR IS THERE ANY DOCUMENTATION IN THE SIGNATURE FOLDER | | FILE. THERE WERE NO SHEETS SUBMITTED IN THE PAPER | | DOCUMENTS FOR THESE TRADES, FIRE SPRINKLER, ELECTRICAL, | | MECHANICAL & PLUMBING. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | 2016-11-22 12:38:30 | DIGITALLY SIGNED PLANS RECIEVED VIA FEDEX, PUT TO | | JWITMER'S DESK |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2016-11-02 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-02 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-02 |
Time |
16:04 |
Sent To |
|
|
Notes |
2016-11-02 16:07:24 | NONE OF THE PAGES IN THIS PLAN SET HAVE BEEN DIGITALLY | | SIGNED | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | 2016-10-26 16:45:53 | NONE OF THE ARCHITECTURAL SHEETS NOR SK-1.0 ARE SIGNED | | NOR SEALED ELECTRONICLLY. JW. |
|
|