Plan Review Details - Permit 15061222
Plan Review Stops For Permit 15061222 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-08-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-18 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-18 |
Time |
12:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-14 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-14 |
Time |
11:38 |
Sent To |
|
|
Notes |
2015-07-14 12:08:50 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 | | [email protected] | | | | FBC FLORIDA BUILDING CODE 2010 | | | | 1ST REVIEW: TEST REPORTS FOR QUIETWALK UNDERLAYMENT, | | LAMINATE FLOORING WERE SUBMITTED | | 2ND REVIEW: SPEC SHEETS FOR QUIETWALK SUBMITTED | | | | FROM PREVIOUS LIST: | | | | 1. FBC 1207.2, THE ASSEMBLY TESTED USED AN 8" SLAB FOR | | THE STC TEST. PROVIDE THE SLAB THICKNESS FOR THIS | | PROJECT. IF THE SLAB IS NOT 8", ADDITIONAL INFORMATION | | WILL BE REQUIRED SUCH AS A TEST REPORT WHICH USES AN 6" | | SLAB (LIKE THE IIC TEST), A DESIGN PROFESSIONAL'S | | COMPARATIVE ANALYSIS, OR THE MANUFACTURER'S ANALYSIS | | (ON LETTERHEAD). | | | | 2ND REVIEW, THIS WAS NOT PROVIDED. MORE SPEC SHEETS | | WERE PROVIDED. SLAB THICKNESS FOR THIS JOB NOT | | PROVIDED, ANALYSIS (OR TEST USING A 7" OR 6" SLAB) NOT | | PROVIDED. | | | | 2. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | E 84 OR UL 723. | | | | 2ND REVIEW, NOT ADDRESSED. | | | | 3. TWO COMPLETE COLLATED SETS OF ALL DOCUMENTS REQUIRED | | FOR PERMIT ISSUANCE, FBC 107. | | | | NEW COMMENT: | | | | 4. SPEC SHEETS ARE NOT ACCEPTABLE IN LIEU OF TEST | | REPORTS DUE TO GENERAL DISCREPANCIES. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-06 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-06 |
Time |
10:06 |
Sent To |
|
|
Notes |
2015-07-06 10:10:31 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 | | [email protected] | | | | FBC FLORIDA BUILDING CODE 2010 | | | | TEST REPORTS FOR QUIETWALK UNDERLAYMENT, LAMINATE | | FLOORING WERE SUBMITTED | | | | 1. FBC 1207.2, THE ASSEMBLY TESTED USED AN 8" SLAB FOR | | THE STC TEST. PROVIDE THE SLAB THICKNESS FOR THIS | | PROJECT. IF THE SLAB IS NOT 8", ADDITIONAL INFORMATION | | WILL BE REQUIRED SUCH AS A TEST REPORT WHICH USES AN 6" | | SLAB (LIKE THE IIC TEST), A DESIGN PROFESSIONAL'S | | COMPARATIVE ANALYSIS, OR THE MANUFACTURER'S ANALYSIS | | (ON LETTERHEAD). | | | | 2. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | E 84 OR UL 723. | | | | 3. TWO COMPLETE COLLATED SETS OF ALL DOCUMENTS REQUIRED | | FOR PERMIT ISSUANCE, FBC 107. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-08-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-08-18 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-08-14 |
Time |
14:28 |
Sent To |
|
|
Notes |
2015-08-14 14:29:21 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-14 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-06 |
Time |
13:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-07-06 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-07-06 |
Time |
10:10 |
Sent To |
|
|
Notes |
|
|
|