Plan Review Details - Permit 15061031
Plan Review Stops For Permit 15061031 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-07-29 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-07-29 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-07-29 |
Time |
17:07 |
Sent To |
ENG |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-08-06 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-08-06 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-06 |
Time |
10:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-06-24 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-06-24 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-24 |
Time |
16:29 |
Sent To |
|
|
Notes |
2015-06-24 16:35:40 | 6/24/2015 | | PROJECT: TROLLEY SHELTER 2 | | PERMIT#: 15061031 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | COMMENTS: | | | | 1) PROVIDE MANUFACTURER SPECS ON THE SOLAR PANEL AND | | LIGHT FIXTURES IN COMPLIANCE WITH NEC 110.3 AND NEC | | 690. | | | | 2) PROVIDE PLANS DETAILS FOR THE ELECTRICAL CONNECTIONS | | AND GROUNDING FOR THE SOLAR PANELS AND LIGHT FIXTURES. | | NEC 690, 300 AND 250 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2015-08-24 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-08-24 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-08-24 |
Time |
09:46 |
Sent To |
|
|
Notes |
2015-08-24 09:47:15 | COVERED UNDER ROW PERMIT 15070326 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2015-08-03 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-08-03 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-08-03 |
Time |
14:20 |
Sent To |
|
|
Notes |
2015-08-03 14:21:03 | RIGHT OF WAY PERMIT IS REQUIRED PRIOR TO START OF | | CONSTRUCTION. | | | | KELLY CRANFORD, P.E. | | LAND DEVELOPMENT ENGINEER | | PUBLIC WORKS DEPARTMENT | | CITY OF WEST PALM BEACH | | [email protected] | | 561-494-1098 (OFFICE) |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-08-03 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-08-03 |
Time |
14:21 |
Rev Time |
|
Received By |
cranford |
Date |
2015-06-23 |
Time |
|
Sent To |
Z |
|
Notes |
2015-06-24 16:36:00 | SENT TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-08-03 |
Time |
14:21 |
Rev Time |
|
Received By |
|
Date |
2015-07-08 |
Time |
|
Sent To |
|
|
Notes |
2015-07-15 11:36:09 | REVIEWED BY A. HANSEN, SENT TO MISC. 2 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |