Plan Review Details - Permit 15061002
Plan Review Stops For Permit 15061002 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-06-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-26 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-26 |
Time |
12:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-06-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-25 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-25 |
Time |
10:32 |
Sent To |
|
|
Notes |
2015-06-25 11:10:09 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC-RESIDENTIAL | | | | 1- TU PLUS ROOF TILE UNDERLAYMENT FL5259-R22: | | SELF-ADHERING UNDERLAYMENTS NEED TO COMPLY WITH THE | | DESIGN PRESSURES OF ALL ROOF ZONES. MAXIMUM DESIGN | | PRESSURE FOR SELECTED UNDERLAYMENT 5.6.4.1 IS -90 PSF. | | THIS PRESSURE DOESN'T MEET THE CORNERS DESIGN | | PRESSURES.THIS BUILDING IS LOCATED IN EXPOSURE "C" AND | | THE DESIGN PRESSURE FOR CORNER AREAS IS -95.12 PSF. | | PLEASE SELECT ANOTHER ASSEMBLY THAT MEETS THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, INCLUDING THE CORNER | | AREAS. SEC. R301 OF 2010 FBC-RESIDENTIAL. | | | | IF YOU HAVE ANY QUESTION, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | | . |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-06-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-24 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-24 |
Time |
16:14 |
Sent To |
|
|
Notes |
2015-06-24 16:39:47 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC-RESIDENTIAL | | | | 1- TU PLUS ROOF TILE UNDERLAYMENT FL5259-R22: | | SELF-ADHERING UNDERLAYMENTS NEED TO COMPLY WITH THE | | DESIGN PRESSURES OF ALL ROOF ZONES. CLEARLY IDENTIFY | | WHICH MAXIMUM DESIGN PRESSURES FROM SEC. 5.6.4 OF | | FLORIDA PRODUCT APPROVAL IS GOING TO BE INSTALLED TO | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | R301 OF 2010 FBC-RESIDENTIAL. | | | | 2- VALUATION WAS UPDATED TO $10,353 AS REQUIRED BY SEC. | | 109.3 CITY AMENDMENTS. THE PERMIT FEE BALANCE IS | | $262.88. | | | | IF YOU HAVE ANY QUESTION, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | | . |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |