Plan Review Details - Permit 15060923
Plan Review Stops For Permit 15060923 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-09-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-08 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-08 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-08-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-08-20 |
Time |
18:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-08-20 |
Time |
18:17 |
Sent To |
|
|
Notes |
2015-08-20 18:50:48 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SHOW COMPLIANCE WITH FBC EXISTING BUILDING 604.1 FOR | | EGRESS WINDOWS IN THE SECOND FLOOR BEDROOM. THE | | EXISTING 30" X 36" BEDROOM WINDOWS WERE JALOSIE WINDOWS | | WHICH WOULD ALLOW THE SLATS TO BE REMOVED OR EASILY | | BROKEN OUT IN AN EMERGENCY. THE PROPOSED IMPACT RATED | | SINGLE HUNG WINDOWS WILL NOT PROVIDE A LARGE ENOUGH | | CLEAR OPENING AND WOULD BE VERY DIFFICULT TO BREAK. I | | WOULD SUGGEST THAT YOU CONSIDER INSTALLING A CASEMENT | | WINDOW IN THE BEDROOM. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-09-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-08 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-09-08 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-08-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-08-20 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-08-20 |
Time |
17:02 |
Sent To |
|
|
Notes |
2015-08-20 17:26:29 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY ELECTRICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) NEC 250.52 & 210.70 - PROVIDE AN ELECTRICAL FLOOR | | PLAN SHOWING THE LOCATION OF ALL REQUIRED LIGHTING AND | | RECEPTACLE OUTLETS AND SHOW CIRCUITS. | | | | 2) NEC 220.40 - SUBMIT ELECTRICAL LOAD CALCULATIONS. | | | | 3) FBC 107.3.5.3 - SUBMIT PANEL SCHEDULES. | | | | 4) NEC 240.24(A) & (B) PANELS SHALL BE READILY | | ACCESSIBLE AND EACH OCCUPANT SHALL HAVE READY ACCESS. | | SPECIFY THE LOCATIONS OF THE PANELS ON THE ELECTRICAL | | FLOOR PLAN. | | | | 5) FBC- 107.3.5.3 - PROVIDE AN ELECTRIC SERVICE RISER | | WITH WIRE SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. | | | | 6) NEC 110.9 - SPECIFY THE A.I.C. RATING OF THE | | ELECTRICAL EQUIPMENT ON THE PLANS. | | | | 7) NEC 210.70 (A) (2) - PROVIDE AT LEAST ONE WALL | | SWITCH CONTROLLED LIGHTING OUTLET TO PROVIDE | | ILLUMINATION ON THE EXTERIOR SIDE OF OUTDOOR ENTRANCES | | OR EXISTS WITH GRADE LEVEL ACCESS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-09-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-09-08 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-08-31 |
Time |
15:20 |
Sent To |
|
|
Notes |
2015-08-31 15:21:26 | MCDOUGAL'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-08-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-08-20 |
Time |
18:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-06-22 |
Time |
09:43 |
Sent To |
|
|
Notes |
2015-06-22 09:44:08 | SENT TO R6 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-09-08 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-08 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-08 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-07-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-07-20 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-07-20 |
Time |
09:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-06-30 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-06-30 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-06-30 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
|