Plan Review Details - Permit 15060725
Plan Review Stops For Permit 15060725
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-09-03 Cont ID  
Sent By jwitmer Date 2015-09-03 Time 10:36 Rev Time 0.00
Received By jwitmer Date 2015-09-03 Time 09:17 Sent To  
Notes
2015-09-03 14:49:12MALBARRAN'S DESK
2015-09-03 10:36:15BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15060725
 ADD: 222 LAKEVIEW AVE.
 CONT: FASTRACK
 TEL: (561)304-7881
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JULY 07/ 2015
 ACTION: BUILDING PROVISO
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) SHEET A2.1 DETAIL J10 ELEVATION & A3.1 DETAIL E14
 THE HEADER OVER GARAGE DOOR OPENINGS NEEDS TO SHOW
 COMPLIANCE WITH 2010 FBC-B
 2104.1 MASONRY CONSTRUCTION. MASONRY CONSTRUCTION SHALL
 COMPLY WITH THE REQUIREMENTS OF SECTIONS 2104.1.1
 THROUGH 2104.4 AND WITH TMS 602/ACI 530.1/ASCE 6.
 ACI 530.1 SECTION 7.5.3.1 SHEAR REINFORCEMENT (STIRRUPS
 OR HAIRPINS) SHALL BE PROVIDED PARALLEL TO THE
 DIRECTION OF APPLIED SHEAR FORCE. SPACING OF THE SHEAR
 REINFORCEMENT SHALL NOT EXCEED THE LESSER OF D/2 OR 48
 INCHES. D- BOTTOM STEEL TO TOP OF BEAM.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-07-07 Cont ID  
Sent By jwitmer Date 2015-07-07 Time 16:13 Rev Time  
Received By jwitmer Date 2015-07-07 Time   Sent To  
Notes
2015-07-07 16:20:21BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15060725
 ADD: 222 LAKEVIEW AVE.
 CONT: FASTRACK
 TEL: (561)304-7881
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JULY 07/ 2015
 ACTION: DENIED
  
 1) SHEET A3.1 PROVIDES WIND PRESSURES BUT NOT HOW THEY
 WERE DERIVED, PLEASE PROVIDE THE WIND DESIGN CRITERIA.
 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 1.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 1.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 1.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 1.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 1.5) COMPONENTS & CLADDING PRESSURES POSITIVE &
 NEGATIVE TABLE 1609.2(2) .
  
 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 3) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (C) WALL LOUVERS,
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-09-10 Cont ID  
Sent By albarran Date 2015-09-10 Time 19:59 Rev Time 0.00
Received By albarran Date 2015-09-10 Time 19:45 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-07-23 Cont ID  
Sent By albarran Date 2015-07-23 Time 16:06 Rev Time 0.00
Received By albarran Date 2015-07-23 Time 15:22 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-08-21 Cont ID  
Sent By pleduc Date 2015-08-21 Time   Rev Time 0.00
Received By pleduc Date 2015-08-21 Time 12:27 Sent To  
Notes
2015-08-21 12:28:14THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) THE OVERHEAD DOOR PROVIDES A SPRINKLER HEAD
 OBSTRUCTION THAT SHALL BE CORRECTED. DUE TO THE REMODEL
 A FIRE SPRINKLER HEAD COVERAGE EVALUATION IS REQUIRED.
 SEPARATE SHOP ARE REQUIRED FOR ANY FIRE SPRINKLER WORK.
  
 3) A FIRE ALARM NOTIFICATION DEVICE MAY BE REQUIRED
 INSIDE THE GARAGE.THE FIRE INSPECTOR WILL TEST AUDIBLE
 LEVELS AT INSPECTION. SEPARATE SHOP ARE REQUIRED FOR
 ANY FIRE ALARM WORK.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-06-25 Cont ID  
Sent By pleduc Date 2015-06-25 Time   Rev Time 0.00
Received By pleduc Date 2015-06-25 Time 11:55 Sent To  
Notes
2015-06-25 12:42:45THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) PROVIDE A EXIT SIGN AT THE MANDOOR.
  
 2) THE OVERHEAD DOOR PROVIDE A SPRINKLER HEAD
 OBSTRUCTION THAT SHALL BE CORRECTED. DUE TO THE REMODLE
 A FIRE SPRINKLER HEAD COVERAGE EVALUATION IS
 REQUIRED.PROVIDE A PROPOSED FIRE SPRINKLER PLAN.
 SEPARATE SHOP ARE REQUIRED FOR ANY FIRE SPRINKLER WORK.
  
 3) A FIRE ALRM NOTIFICATION DEVICE IS REQUIRED INSIDE
 THE GARAGE. A FIRE ALARM NOTIFICATION REVIEW IS
 REQUIRED. PROVIDE A PROPOSED FIRE ALARM PLAN. SEPARATE
 SHOP ARE REQUIRED FOR ANY FIRE ALARM WORK.
  
 4) PROVIDE A NOTE INDICATING THE ACTIVIATION AND
 DURATION OF THE VENTILATION FAN.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-09-10 Cont ID  
Sent By albarran Date 2015-09-10 Time 20:04 Rev Time 0.00
Received By albarran Date 2015-08-20 Time 13:22 Sent To  
Notes
2015-09-10 20:08:519/10/15 - PASSED ELECTRICAL REVIEW. ATTEMPT TO CONTACT
 CONTRACTOR WAS MADE BUT THE PHONE NUMBER DOES NOT TAKE
 MESSAGES AND THE EMAIL AS GIVEN PROVED TO BE INCORRECT.
 SENT TO LARGE READY BIN "F". MA
2015-08-20 13:22:17C03

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-23 Cont ID  
Sent By albarran Date 2015-07-23 Time 16:10 Rev Time 0.00
Received By albarran Date 2015-06-16 Time 16:49 Sent To  
Notes
2015-07-23 16:15:267/23/15 - BEEN THROUGH ALL TRADE REVIEWS AND IS READY
 FOR CORRECTIONS. CONTRACTOR NOTIFIED VIA EMAIL. SENT TO
 LARGE DENIED BIN "F". MA
2015-06-16 16:49:31C07
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-09-02 Cont ID  
Sent By ccole Date 2015-09-02 Time 07:40 Rev Time 0.00
Received By ccole Date 2015-09-02 Time 07:17 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-06-29 Cont ID  
Sent By hmoser Date 2015-06-29 Time 14:21 Rev Time 0.00
Received By hmoser Date 2015-06-29 Time 13:43 Sent To  
Notes
2015-06-29 14:21:46PLAN DENIED
 1) PROVIDE NOA FOR EXHAUST LOUVER WERE IT TERMINATES TO
 THE OUTSIDE
 PER SECTION 107.3.4.1 GENERAL. 2010 FBC
 2) PROVIDE SEQUENCE OF OPERATION FOR EXHAUST FAN
 3) REFER TO SECTION 404.1 ENCLOSED PARKING GARAGES
 2010 FBC (M)
 4) REFER TO SECTION 401.4.1 INTAKE OPENING 2010 FBC (M)
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-09-14 Cont ID  
Sent By aaponte Date 2015-09-14 Time 10:15 Rev Time 0.00
Received By aaponte Date 2015-09-14 Time 10:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-07-16 Cont ID  
Sent By aaponte Date 2015-07-16 Time 11:46 Rev Time 0.00
Received By aaponte Date 2015-07-16 Time 11:46 Sent To  
Notes
2015-07-16 11:48:52TO ACCES THE PROPOSED ENCLOSED PARKING SPACE TWO
 EXISTING PARKING SPACES WILL HAVE TO BE REMOVED. PLEASE
 PROVIDE INFORMATION TO CONFIRM PARKING STILL COMPLIES
 WITH PD APPROVAL.
 BACK UP AREA FOR PROPOSED PARKING SPACE SHALL BE 24
 FEET.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.