Plan Review Stops For Permit 15060717 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-01-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-01-26 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-01-26 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-11-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-11-24 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-11-24 |
Time |
11:30 |
Sent To |
|
|
Notes |
2015-11-24 11:31:53 | BUILDING PLAN REVIEW | | W. P. B. REVISION: 15060717 | | W. P. B. PERMIT: 14110854 | | ADD: 5335 N. MILITARY TRAIL | | CONT: SISCA CONSTRUCTION | | TEL: (561)864-4779 | | E-MAIL: ???????????????? | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | E-MAIL SENT TO: | | DATE: MON. NOV. 23/2015 | | ACTION: DENIED | | | | E-MAIL SENT TO: DOREEN HAIR | | , | | DOREEN, | | I'VE PULLED THE PLANS AND FOUND NEW CALCULATIONS DATED | | 11/13/15. EVERYTHING LOOKED GOOD UNTIL I GOT TO PAGES | | 18 & 19 WIND LOAD CERTIFICATIONS PREPARED BY PAUL WELCH | | P.E. THESE DOCUMENTS WERE COPIED. ON THE SHEETS YOU CAN | | SEE PART OF THE ENGINEER'S (PAUL WELCH) EMBOSSED SEAL | | AND SIGNATURE, THEN DAVID SANSOTTA SIGNED AND SEALED | | ANOTHER ENGINEER'S WORK!!!!!!! THAT IS A NO,NO!!!!!! IF | | MR. SANSOTTA IS NOT THE ENGINEER OF RECORD FOR THE | | PROJECT. IF HE IS TO INCLUDE ANOTHER ENGINEERS WORK | | WITHIN THE REPORT IT NEEDS TO BE ORIGINALS AND SO | | NOTED. THE STRUCTURAL SHEETS WERE SIGNED AND SEALED BY | | DAVID MULLINS THE ARCHITECT. MR. MULLINS IS THE ONE | | THAT SHOULD PUT THEIR SHOP DRAWING STAMP OF APPROVAL ON | | ALL OF THE DOCUMENTS BY BOTH ENGINEERS. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-11-23 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-11-23 |
Time |
06:28 |
Sent To |
|
|
Notes |
2015-11-24 06:59:08 | BUILDING PLAN REVIEW | | W. P. B. REVISION: 15060717 | | W. P. B. PERMIT: 14110854 | | ADD: 5335 N. MILITARY TRAIL | | CONT: SISCA CONSTRUCTION | | TEL: (561)864-4779 | | E-MAIL: ???????????????? | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: MON. NOV. 23/2015 | | ACTION: DENIED | | | | CALCULATIONS DATED : 7/27/2015 2ND VERSION DATED: | | 8/28/2015 | | | | 1) STRUCTURAL EDGE ENGINEERING P. E. DAVID SANOTTA.: | | 1A) 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR | | INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED | | AND THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF | | THE PRODUCTION & PREPARATION OF EACH SECTION OF THE | | ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION | | ON THE COVER SHEET OR INDEX LISTING HOW MANY PAGES ARE | | COVERED UNDER THE COVER SHEET OR INDEX SHEET. | | | | 1B) CODE REFERANCED IS THE 2012 IBC, PLEASE NOTE THIS | | PROJECT WAS REVIEWED UNDER THE 2010 FBC, THE ADOPTED | | CODE. | | | | 1C) SHEET # 3 LIST THE EXPOSURE AS A EXPOSURE B, PLEASE | | UPDATE THE STRUCTURAL CALCULATIONS TO AN EXPOSURE C. | | 2010 FBC-B 1609.4.2 .THIS SURFACE ROUGHNESS SHALL ALSO | | APPLY TO ANY BUILDING LOCATED WITHIN SURFACE ROUGHNESS | | B-TYPE TERRAIN WHERE THE BUILDING IS WITHIN 100 FEET | | HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF SURFACE | | ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE THAN | | 600 FEET (182.9 M) AND WIDTH GREATER THAN 150 FEET IN | | THE UPWIND DIRECTION. SHORT-TERM (LESS THAN TWO YEAR) | | CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE, FOR THE | | PURPOSES OF DEVELOPMENT, SHALL NOT BE CONSIDERED | | SURFACE ROUGHNESS C. | | | | 1D) REFERENCES THE 2012 IBC, NOTE THIS PROJECT SHOULD | | BE DESIGNED UNDER THE 2010 FBC-B. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-09-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-09-04 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-09-04 |
Time |
14:37 |
Sent To |
|
|
Notes |
2015-09-04 14:49:27 | BUILDING PLAN REVIEW | | W. P. B. REVISION: 15060717 | | W. P. B. PERMIT: 14110854 | | ADD: 5335 N. MILITARY TRAIL | | CONT: SISCA CONSTRUCTION | | TEL: (561)864-4779 | | E-MAIL: ???????????????? | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. SEPT. 04/2015 | | ACTION: DENIED | | | | CALCULATIONS DATED : 7/27/2015 2ND VERSION DATED: | | 8/28/2015 | | | | 1) STRUCTURAL EDGE ENGINEERING P. E. DAVID SANOTTA.: | | 1A) 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR | | INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED | | AND THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF | | THE PRODUCTION & PREPARATION OF EACH SECTION OF THE | | ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION | | ON THE COVER SHEET OR INDEX LISTING HOW MANY PAGES ARE | | COVERED UNDER THE COVER SHEET OR INDEX SHEET. | | | | 1B) CODE REFERANCED IS THE 2012 IBC, PLEASE NOTE THIS | | PROJECT WAS REVIEWED UNDER THE 2010 FBC, THE ADOPTED | | CODE. | | | | 1C) SHEET # 3 LIST THE EXPOSURE AS A EXPOSURE B, PLEASE | | UPDATE THE STRUCTURAL CALCULATIONS TO AN EXPOSURE C. | | 2010 FBC-B 1609.4.2 .THIS SURFACE ROUGHNESS SHALL ALSO | | APPLY TO ANY BUILDING LOCATED WITHIN SURFACE ROUGHNESS | | B-TYPE TERRAIN WHERE THE BUILDING IS WITHIN 100 FEET | | HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF SURFACE | | ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE THAN | | 600 FEET (182.9 M) AND WIDTH GREATER THAN 150 FEET IN | | THE UPWIND DIRECTION. SHORT-TERM (LESS THAN TWO YEAR) | | CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE, FOR THE | | PURPOSES OF DEVELOPMENT, SHALL NOT BE CONSIDERED | | SURFACE ROUGHNESS C. | | | | 1D) FERERENCES THE 2012 IBC, NOTE THIS PROJECT SHOULD | | BE DESIGNED UNDER THE 2010 FBC-B. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2015-07-29 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-29 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-29 |
Time |
14:25 |
Sent To |
I |
|
Notes |
2015-07-29 14:33:47 | 7/29/15 - THIS WAS GIVEN TO ME BY CC TO DO THE INCOMING | | AND STAMP NEW ELECTRICAL PAGES. ELECTRICAL PAGES WERE | | ALREADY STAMPED, SO NEW STAMP WAS UNNECESSARY. SENT TO | | SMALL DENIED BIN "S". MA |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-06-22 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-06-22 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-22 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2016-01-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-01-26 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-01-25 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-11-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-11-23 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-11-18 |
Time |
13:48 |
Sent To |
|
|
Notes |
2015-11-18 13:48:32 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-09-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-09-04 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-09-02 |
Time |
15:53 |
Sent To |
|
|
Notes |
2015-09-02 15:53:46 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-29 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-29 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-28 |
Time |
10:24 |
Sent To |
|
|
Notes |
2015-07-29 14:34:29 | 7/29/15 - THIS WAS GIVEN TO ME BY CC TO DO THE INCOMING | | AND STAMP NEW ELECTRICAL PAGES. ELECTRICAL PAGES WERE | | ALREADY STAMPED, SO NEW STAMP WAS UNNECESSARY. SENT TO | | SMALL DENIED BIN "S". MA | 2015-07-29 10:24:39 | CCOLE DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-06-22 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-06-22 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-16 |
Time |
17:02 |
Sent To |
|
|
Notes |
2015-06-16 17:02:16 | TO MECH BOX | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2015-11-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-11-19 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-11-19 |
Time |
08:55 |
Sent To |
|
|
Notes |
2015-11-19 08:58:12 | MECHANICAL PROVISO | | PERMIT #15060717 | | 11/19/15 | | | | 1) WIND LOAD ENGINEERING FOR TIE-DOWN OF THE RELOCATED | | RTU-3 SHALL BE SUBMITTED TO THE BUILDING DEPT. PRIOR TO | | 1ST INSPECTION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2015-09-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-09-03 |
Time |
07:24 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-09-02 |
Time |
17:07 |
Sent To |
|
|
Notes |
2015-09-03 08:15:12 | 2ND REVIEW: FBC 2010 MECHANICAL | | PERMIT #15060717 | | 9/3/15 | | | | 1) PAGE 20 OF THE SUBMITTED TIE-DOWN ENGINEERING FROM | | STRUCTURAL EDGE ENGINEERING SHOWS MULTIPLE OPTIONS FOR | | ATTACHING THE RTU TO THE CURB. A SITE SPECIFIC DETAIL | | IS REQUIRED- OPTIONS ARE NOT ACCEPTABLE TO THE WPB | | BUILDING DEPARTMENT. PLEASE NOTE THAT WELDING THE UNIT | | TO THE CURB MUST BE IN COMPLIANCE WITH THE | | MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PLEASE | | PROVIDE EVIDENCE THAT THIS IS AN ACCEPTABLE METHOD BY | | THE MANUFACTURER- OTHERWISE THE PRODUCT WARRANTY MAY BE | | VOIDED. | | 2) SUBMIT PRODUCT DATA (CUT) SHEETS FOR THE RTU CURB |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2015-07-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-07-29 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-07-29 |
Time |
11:49 |
Sent To |
|
|
Notes |
2015-07-29 12:04:53 | 2ND REVIEW: FBC 2010 MECHANICAL | | | | 1) THE LOCATION OF RTU #3 SHOWN IN THE NEW STRUCTURAL | | 8-1/2 X 11 PLAN SHEET SUBNITTAL DOES NOT MATCH THE | | RE-LOCATION ON THE M-1 PLAN. | | 2) THE SUBMITTED 8-1/2 STRUCTURAL DRAWING INDICATES | | "EXISITING CURB TO DECK ATTACHMENT TO REMAIN". HOW IS | | THIS POSSIBLE IF THE UNIT HAS BEEN RELOCATED TO A SPOT | | WHERE THERE WASN'T A PRIOR CURB OR ROOF OPENING | | EXISTING? PLEASE PROVIDE COMPLETE STRUCTUAL DRAWINGS | | FOR THE INSTALLATION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-06-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-06-17 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-06-17 |
Time |
12:29 |
Sent To |
E |
|
Notes |
2015-06-17 12:40:48 | 1ST REVIEW: FBC 2010 MECHANICAL | | | | 1) THE REVISION INDICATES THE RELOCATION OF RTU #3 FROM | | THE ROOF ABOVE THE EXERCISE AREA TO THE ROOF ABOVE THE | | LOCKER/REST ROOM AREA: PROVIDE REVISIONS TO THE | | STRUCTURAL DRAWINGS AND DETAILS. | | 2) REVISE THE ENERGY CALCULATIONS TO SHOW THE CHANGE | | FROM THE 15 SEER YORK RTU'S TO THE 13 SEER CARRIER | | RTU'S | | | | CHRISTOPHER COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|