Plan Review Details - Permit 15060508
Plan Review Stops For Permit 15060508 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-07-16 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-16 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-16 |
Time |
14:38 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-07-08 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-08 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-08 |
Time |
16:01 |
Sent To |
I |
|
Notes |
2015-07-08 16:14:35 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | THE CORRECTIONS NOTED.. | | | | THE FOLLOWING ITEMS SHALL BE CORRECTED AND THE PLANS | | RESUBMITTED FOR A SECOND REVIEW: | | 1. PROVIDE AN EASIER TO UNDERSTAND RISER DIAGRAM. THIS | | DIAGRAM SHALL INDICATE LINE SIDE OF METER WHETHER | | OVERHEAD OR UNDERGROUND. | | 2. YOU SHALL PROVIDE LOAD CALCS FOR THE COMPLETE | | RESIDENCE, NOT JUST THE GENERATOR LOAD. | | 3. FROM THE SUBMITTED RISER, IT APPEARS THAT BOTH | | PANELS ARE ON THE LOAD SIDE OF THE ATS. | | 4. PER NEC ALL CONDUCTORS INSIDE AN UNDERGROUND RACEWAY | | SHALL BE LISTED FOR WET LOCATION AND THHN IS NOT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU | | | 2015-06-18 11:17:32 | SENT TO GENERATOR BIN |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-16 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-16 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-16 |
Time |
12:43 |
Sent To |
|
|
Notes |
2015-07-16 15:11:03 | 7/16/15 - PASSED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED | | VIA EMAIL. SENT TO SMALL READY BIN "A". MA | 2015-07-16 12:43:49 | RESUB ROUTED TO MA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-07-08 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-08 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-06-11 |
Time |
14:05 |
Sent To |
|
|
Notes |
2015-07-08 16:18:57 | 7/8/15 - FAILED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED | | VIA EMAIL. SENT TO SMALL DENIED BIN "A". MA | 2015-06-11 14:14:58 | ROUTED TO R04 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-06-18 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-06-18 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-06-18 |
Time |
15:39 |
Sent To |
B |
|
Notes |
|
|
|