2015-06-10 17:26:13 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 15060375 |
| ADD: 525 S FLAGLER DR SUITE 8B |
| CONT: WALTLEE CONSTRUCTION |
| TEL: (856-6655 |
| E-MAIL: [email protected] |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: WED. JUNE 10/ 2015 |
| ACTION: DENIED |
| |
| 1) THE PERMIT APPLICATION UNDER THE HEADING DESCRIPTION |
| OF WORK INDICATES, TUB CHANGE OUT, NEW TILE. THE |
| DESCRIPTION OF NEW TILE DOES NOT INDICATE IF FLOOR TILE |
| OR WALL TILE ARE GOING TO BE REPLACED. |
| WITH THE REPLACEMENT OF WALL TILE, PLEASE BE AWARE OF |
| COMPLIANCE WITH 2010 FBC-B 2509.3. LIMITATIONS. WATER |
| RESISTANT GYPSUM BOARD SHALL NOT BE USED IN THE |
| FOLLOWING LOCATIONS: |
| 1. OVER A VAPOR RETARDER IN SHOWERS OR BATHTUB |
| COMPARTMENTS. |
| |
| 2) IF FLOOR TILE IS TO BE REPLACED IN THE BATHROOM, |
| THEN THE FOLLOWING FLOOR INSULATION TEST REPORTS WILL |
| BE REQUIRED: |
| |
| BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION |
| |
| 2A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| |
| 2B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND. |
| WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E 90. |
| |
| 2C) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2. |
| INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| |
| FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |