Plan Review Details - Permit 15060115
Plan Review Stops For Permit 15060115 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-06-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-08 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-08 |
Time |
16:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-06-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-08 |
Time |
09:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-08 |
Time |
09:23 |
Sent To |
|
|
Notes |
2015-06-08 09:43:22 | RE-ROOF BUILDING REVIEW COMMENTS. | | CODE 2010 FBC | | | | 1- RAS 117 CALCULATIONS SUBMITTED: ENGINEER TO PROVIDE | | ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471 | | F.S. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-06-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-05 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-05 |
Time |
15:35 |
Sent To |
|
|
Notes |
2015-06-05 17:17:19 | RE-ROOF BUILDING REVIEW COMMENTS. | | CODE 2010 FBC | | | | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL1654-R14 | | SUBMITTED: | | A) THE DESIGN PRESSURES FOR THE SELECTED ASSEMBLY | | (W-49) IS -90PSF. THIS BUILDING IS LOCATED IN EXPOSURE | | "C". THE CORNER PRESSURES FOR THIS BUILDING ARE HIGHER | | THAN -90PSF. THIS ASSEMBLY CAN NOT BE USED BECAUSE | | RATIONAL ANALYSIS IS NOT ALLOWED FOR NAIL ENHANCING. | | SEE NOTE #9 ON PAGE 2 OF 33. NEED TO SELECT ANOTHER | | ASSEMBLY THAT MEETS ALL THE DESIGN PRESSURES OR ANOTHER | | ASSEMBLY THAT ALLOWS RATIONAL ANALYSIS (SIGNED AND | | SEALED RAS 117 CALCULATIONS). OR PROVIDE ANOTHER | | PRODUCT APPROVAL. SEC. 1609 OF 2010 FBC-BUILDING. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-06-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-08 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-08 |
Time |
16:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-06-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-05 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-06-03 |
Time |
|
Sent To |
B |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy