Plan Review Stops For Permit 15051296 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-07-31 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-07-31 |
Time |
06:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-07-31 |
Time |
06:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-09 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-09 |
Time |
06:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-06-29 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-06-29 |
Time |
19:25 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-06-29 |
Time |
18:54 |
Sent To |
|
|
Notes |
2015-06-29 19:27:54 | SHALL INSTALL THE REQUIRED SIGNED OUTLET ABOVE/ADJACENT | | TO ENTRY DOOR. (NEC 600.5). | | CROSSED OUT AN INCORRECTLY QUOTED CODE SECTION (230.98) | | ROMEX IS A BRAND NAME, NM CABLE IS SUBSTITUTED FOR | | ROMEX. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-06-03 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-06-03 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-06-03 |
Time |
12:02 |
Sent To |
|
|
Notes |
2015-06-03 12:09:37 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | APPLICABLE CODES OR STANDARDS. | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 13, 2010 EDITION. | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 72, 2010 EDITION. | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 241, 2009 EDITION. | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 10, 2010 EDITION. | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-31 |
|
|
Cont ID |
|
Sent By |
|
Date |
2015-07-31 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-07-17 |
Time |
09:17 |
Sent To |
|
|
Notes |
2015-07-23 09:17:45 | ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-07-08 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-07-08 |
Time |
11:09 |
Rev Time |
|
Received By |
lmarchan |
Date |
2015-05-29 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-09 |
Time |
06:50 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-09 |
Time |
06:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-07-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-07-23 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-07-23 |
Time |
12:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-07-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-07-08 |
Time |
07:08 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-07-07 |
Time |
07:08 |
Sent To |
|
|
Notes |
2015-07-08 07:41:28 | 1ST REVIEW: FBC 2010 MECHANICAL | | | | 1) PROVIDE COOLING AND HEATING LOAD CALCULATIONS FOR | | THE PROPOSED AC SYSTEM IN ACCORDANCE WITH ACCA MANUAL N | | OR THE ACCA/ASHRAE STANDARD 183- SECTION 503.2.1 FBC-10 | | ENERGY CONSERVATION. | | 2) SHEET A3: THE PLAN IS INDICATING THE AREA ABOVE THE | | CEILING IS A RETURN AIR PLENUM. REFERENCE SECTION | | 602.2.1 AND ALL APPLICABLE SUB-SECTIONS PERTAINING TO | | NON-COMBUSTIBLE AND OTHER MATERIALS PERMITTED TO BE | | INSTALLED IN THE PLENUM. PLEASE PLACE NOTES ON THE PLAN | | TO VERIFY COMPLIANCE. | | 3) A3: INDICATE THE TYPE AND SIZE OF CONDENSATE PIPING | | AND CLARIFY THE DISCHARGE LOCATION- SECTION 307. THERE | | IS A NOTE ON THE PLAN STATING "PROVIDE COND. TO WET | | COL.": PLEASE CLARIFY IF THIS IS AN EXISTING STORM | | DRAIN RISER. | | 4) A3: PROVIDE UPDATED WIND LOAD TIE-DOWN ENGINEERING | | FOR ANCHORING THE CONDENSER TO THE PAD. THE DETAIL ON | | THE PLAN IS INDICATING A WIND SPEED OF 120 MPH. | | REFERENCE SECTION 301.12 FBC-10 MECHANICAL, AND SECTION | | 1609 FBC-10 BUILDING. THE ULTIMATE DESIGN WIND SPEED | | FOR RISK CATEGORY II IN WEST PALM BEACH IS 170 MPH- SEE | | FIGURE 1609A. REVISE THE DETAIL ACCORDINGLY AND | | INDICATE THE TYPE, SIZE, AND GAGE OF STEEL HURRICANE | | STRAPS TO BE INSTALLED. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-07-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-07-24 |
Time |
02:33 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-07-24 |
Time |
02:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-06-16 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-16 |
Time |
06:41 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-16 |
Time |
06:16 |
Sent To |
|
|
Notes |
2015-06-16 06:15:23 | 1) SHOW THE LENGTH AND WIDTH DIMENSIONS OF BOTH TOILET | | ROOMS. THE MINIMUM WIDTH OF THE TOILET ROOMS SHALL BE | | 85 INCHES WHEN ALL THE PLUMBING FIXTURES ARE LOCATED ON | | THE SAME WALL. 86 INCHES IN WIDTH ALLOWS FOR | | CONSTRUCTION TOLERANCES.WPB AMEND. TO FBC SEC. 107.2.1. | | 2) THE BREAKROOM SINK SHALL COMPLY WITH THE FL. ACCESS. | | CODE SECS. 212, 606, 804. | | 3) THE MAXIMUM HEIGHT OF THE COUNTER OF THE BREAK ROOM | | SINK SHALL BE AT 34 INCHES ABOVE FINISH FLOOR. | | FBC-ACCESSIBILITY SECC.606.3. | | 4) SUBMIT A WATER RISER FOR BOTH TOILET ROOMS. WPB | | AMEND. TO FBC SEC. 107.3.5.1.3. | | 5) CLEANOUTS ARE REQD. IN THE WASTE STACKS PER 2010 | | FBC-PLUMBING, SEC.708.3.4. | | 6) SHT.A-3 - PLUMBING NOTES # 1 & # 8 REFER TO THE 2007 | | FLORIDA PLUMBING CODE. REVISE NOTES TO REFER TO 2010 | | FPC. | | 7) THE LAYOUT/LOCATION OF THE PLUMBING FIXTURES ON THE | | SANITARY RISER DOES NOT CORRELATE WITH THE FLOOR PLAN. | | WPB AMEND. TO FBC SEC. 107.2.1. | | 8) IDENTIFY THE WASTE STACK FOR THE BREAK ROOM SINK. | | BOTH STACKS ARE LABELED AS A LAVATORY. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-06-08 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2015-06-08 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2015-06-08 |
Time |
13:53 |
Sent To |
|
|
Notes |
|
|