Plan Review Details - Permit 15051084
Plan Review Stops For Permit 15051084
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-06-22 Cont ID  
Sent By jwitmer Date 2015-06-22 Time 09:29 Rev Time  
Received By jwitmer Date 2015-06-22 Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-07-08 Cont ID  
Sent By albarran Date 2015-07-08 Time 17:29 Rev Time 0.00
Received By albarran Date 2015-07-08 Time 17:02 Sent To I
Notes
2015-07-08 17:31:21LIGHTING TO COMPLY WITH 2010 FBC-E SECTION 505.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2015-06-18 Cont ID  
Sent By cranford Date 2015-06-18 Time 15:42 Rev Time 0.00
Received By cranford Date 2015-06-18 Time 15:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-05-28 Cont ID  
Sent By pleduc Date 2015-05-28 Time   Rev Time 0.00
Received By pleduc Date 2015-05-28 Time 12:40 Sent To  
Notes
2015-05-28 12:42:42THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE
 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING
 THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER
 APPLICABLE CODES OR STANDARDS.
 FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 13, 2010 EDITION.
 FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 72, 2010 EDITION.
 CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 241, 2009 EDITION.
 FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 10, 2010 EDITION.
 ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION.
 EMERGENCY POWER SHALL COMPLY WITH NFPA 110 2010
 EDITION.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-16 Cont ID  
Sent By ccole Date 2015-07-16 Time 08:52 Rev Time 0.00
Received By ccole Date 2015-07-15 Time 13:36 Sent To  
Notes
2015-07-15 13:36:56RESUB ROUTED TO HMOSER/CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-08 Cont ID  
Sent By albarran Date 2015-07-08 Time 17:40 Rev Time  
Received By albarran Date 2015-05-26 Time   Sent To  
Notes
2015-07-08 17:44:167/8/15 - PASSED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED
 OF OTHER DEFICIENCIES VIA EMAIL. SENT TO LARGE DENIED
 BIN "C". (SMALL FILE IN LARGE BIN) MA
2015-05-26 15:20:10B46.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2015-05-26 Cont ID  
Sent By jwitmer Date 2015-05-26 Time 15:19 Rev Time 0.00
Received By jwitmer Date 2015-05-26 Time 15:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-07-16 Cont ID  
Sent By ccole Date 2015-07-16 Time 08:51 Rev Time 0.00
Received By ccole Date 2015-07-16 Time 08:51 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-07-16 Cont ID  
Sent By ccole Date 2015-06-23 Time 08:52 Rev Time 0.00
Received By ccole Date 2015-06-23 Time 11:08 Sent To  
Notes
2015-06-23 13:25:02PLAN DENIED
 1) PLEASE EXPLAIN WHAT AHU- 1 IS COOLING HALLWAY OR
 CLEAN ROOM
 2) PROVIDE A ENGINEER DETAIL ON CONDENSER STAND TIED TO
 ROOF
 AND CONDENSER TIED TO STAND. PROVIDE TYPE AND SIZE
 ANCHOR USED.
 PER SECTION 301.12 WIND RESISTANCE FBC (M) 2010
 3) PROVIDE HEATING AND COOLING CALCULATIONS. PER
 SECTION
 503.2.1 FLORIDA ENERGY CODE 2010.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2015-06-16 Cont ID  
Sent By tklarge Date 2015-06-16 Time 03:39 Rev Time 0.00
Received By tklarge Date 2015-06-16 Time 03:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-06-04 Cont ID  
Sent By jroach Date 2015-06-04 Time 11:32 Rev Time 0.00
Received By jroach Date 2015-06-04 Time 11:32 Sent To  
Notes
2015-05-27 11:49:425/27/15