Plan Review Details - Permit 15051072
Plan Review Stops For Permit 15051072
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-06-04 Cont ID  
Sent By shill Date 2015-06-04 Time 16:05 Rev Time 0.00
Received By shill Date 2015-06-04 Time 16:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-05-27 Cont ID  
Sent By shill Date 2015-05-27 Time 14:53 Rev Time 0.00
Received By shill Date 2015-05-27 Time 14:53 Sent To  
Notes
2015-05-27 14:53:25****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND
 OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%.
  
 TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION
 NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT:
  
 STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS
 - AWNING, CASEMENT, SINGLE HUNG?
  
 STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE.
 CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE
 WINDOW IS FULLY OPEN.
  
 STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE.
 THIS CAN BE OBTAINED FROM THE MANUFACTURER.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-06-04 Cont ID  
Sent By shill Date 2015-06-04 Time 16:05 Rev Time 0.00
Received By shill Date 2015-05-29 Time   Sent To  
Notes
2015-06-01 18:06:206/1 TO SH DESK
  
2015-05-29 12:09:03MISC 1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-05-27 Cont ID  
Sent By shill Date 2015-05-27 Time 14:53 Rev Time 0.00
Received By shill Date 2015-05-27 Time 14:53 Sent To  
Notes
2015-05-26 13:50:31SENT TO MISC BOX # 1.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved