Plan Review Stops For Permit 15051048 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-09-10 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-09-10 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-09 |
Time |
17:36 |
Rev Time |
|
Received By |
jwitmer |
Date |
2015-06-09 |
Time |
15:44 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-09-28 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-09-28 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-09-28 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-06-04 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-06-04 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-06-04 |
Time |
12:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-08-31 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-08-31 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-08-31 |
Time |
10:43 |
Sent To |
|
|
Notes |
2015-08-31 10:44:22 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | APPLICABLE CODES OR STANDARDS. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-05-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-05-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-05-28 |
Time |
12:17 |
Sent To |
|
|
Notes |
2015-05-28 12:40:09 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | APPLICABLE CODES OR STANDARDS. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-09-28 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-09-28 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-08-28 |
Time |
10:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-06-22 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-22 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-19 |
Time |
17:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
F |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-09 |
Time |
17:46 |
Rev Time |
|
Received By |
jwitmer |
Date |
2015-05-22 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-09 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-09 |
Time |
17:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2015-09-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-09-09 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-09-09 |
Time |
06:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-06-22 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-22 |
Time |
|
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-22 |
Time |
06:07 |
Sent To |
|
|
Notes |
2015-06-22 06:16:34 | 1) THE RELIEF VENT SHOWN IS UNACCEPTABLE AS DRAWN. IT | | DOES NOT MEET THE INTENT OF THE PLUMBING CODE. WHERE | | AND WHAT DOES IT CONNECT TO? COMPLY W/2010 FPC | | SEC.917.3.2. | | 2) SUBMIT THE CALCULATIONS THAT YOU USED TO SIZE THE | | GREASE TRAP UNDER THE 3 COMPARTMENT SINK. I ASKED FOR | | THIS ON MY LAST REVIEW. 2ND REQUEST. | | 3) IN MY LAST REVIEW I STATED THAT THE STACK FOR THE | | MOP SINK WAS A THREE INCH STACK. THE STACK IS A | | CONTINUOUS 3 INCH STACK, NOT A 3 INCH STACK WITH A 2 | | INCH VENT. | | 4) SUBMIT A WATER RISER FOR THE NEW MOP SINK. WPB | | AMEND. TO 2010 FBC SEC. 107.3.5.1.3. 2ND REQUEST. | | 5INDICATE ON THE PLANS IF ANY COOKING WILL BE DONE ON | | THE PREMISES AND IF SO SHOW ALL EQUIPMENT ON THE PLANS. | | 2ND REQUEST. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-09 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-09 |
Time |
16:24 |
Sent To |
|
|
Notes |
2015-06-09 16:56:27 | 1) THE PLANS NOTE THE SCOPE OF PLUMBING WORK TO ADD A | | WASHING MACHINE AND A TANKLESS WATER HEATER. THERE IS | | NO TANKLESS WATER HEATER OR WASHING MACHINE SHOWN ON | | THE PLANS. CLARIFY. | | 2) SUBMIT A WATER RISER DIAGRAM FOR REVIEW. WPB AMEND. | | TO 2010 FBC SEC. 107.3.5.1.3. | | 3) THE PLANS SHOW THE OCCUPANCY AS MERCANTILE. INDICATE | | ON THE PLANS WHAT WILL BE SOLD. THE PLANS SHOW A NEW | | PREP TABLE. WILL THERE BE ANY TYPE OF FOOD PREPARATION | | OR COOKING DONE ON THE PREMISES? INDICATE ON THE | | PLANS.WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 4) A GREASE REMOVAL DEVICE MAY BE REQUIRED DEPENDENT | | UPON THE TYPE OF GOODS BEING PREPARED. SUBMIT | | CALCULATIONS FOR A GREASE TRAP/ INTERCEPTOR IN | | ACCORDANCE WITH FBC-PLUMBING SEC.1003.3.1. | | 5) THE NEW HAND SINK IS SHOWN CONNECTING TO AN EXISTING | | 2" STACK. UPON RESEARCH OF CITY RECORDS, THIS STACK | | APPEARS TO BE AN EXISTING 3"STACK. REVISE. | | 6) SINCE THIS IS A MULTI-STORY BUILDING, THE USE OF A | | AIR ADMITTANCE VALVE ON THE MOP SINK WILL REQUIRE A | | RELIEF VENT IN ACCORDANCE WITH 2010 FBC-PLUMBING | | SEC.917.3.2 OR REVISE THE DESIGN TO A STACK & VENT | | SYSTEM. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|