Plan Review Stops For Permit 15050879 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-12-09 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-12-09 |
Time |
08:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-10-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-17 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-17 |
Time |
17:16 |
Sent To |
|
|
Notes |
2015-10-17 17:43:43 | 3RD REVIEW: FBC 2010 | | | | FBC 107, MINIMUM PLAN REVIEW CRITERIA. THIS REVIEW IS | | DENIED FOR LACK OF INFORMATION AS FOLLOWS: | | | | THE DESIGNER MUST PROVIDE FURTHER DETAILS, TO SPECIFY | | MATERIALS, CONNECTION AND ATTACHMENTS AS FOLLOWS: | | WALL SECTION SHEET A-1.2 & NOTES 09.1 & 09.2: | | ATTACHMENT OF FLOOR JOIST, CEILING JOIST, SPECFY WALL | | STUD SIZE AND OC SPACING AND ALL SHEATHING NAILING. | | | | ADDITIONAL SUBMITTAL IS NEEDED TO CLARIFY THE SELECTED | | WINDOW/DOOR, STORM PANEL AND ROOFING PRODUCTS TO BE | | USED . CLARIFY THE CONFLICT OF NOTE 08.8 VERSUS THE | | PROVIDED SLIDING GLASS DOOR NOA TO ACHIEVE IMPACT | | PROTECTION. THE OTHER DOOR SUBMITTALS ARE NOT CLEAR. A | | ROOFING PRODUCT IS NOT SUBMITTED. A COVER SHEET ONLY | | HAS BEEN PROVIDED FOR STORM PANELS. IF PANELS ARE TO BE | | USED, PROVIDE FULL INFORMATION. | | | | YOU MAY CHOOSE TO DEFER THE PRODUCT APPROVAL | | SUBMITTALS. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-07-13 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-13 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-24 |
Time |
19:46 |
Sent To |
|
|
Notes |
2015-07-11 13:26:07 | 2ND REVIEW: FBC 2010 | | | | NEW COMMENTS: | | | | PROVIDE DETAILS FOR EACH SET OF THE NEW STAIRS, | | LANDINGS, AND HANDRAILS. | | | | EXPLAIN TO WHICH PART OF THE BUILDING THE WALL SECTION | | ON SHEET A-1.2 APPLIES. | | | | FBC 107.3.5.1.6 ENERGY CALCULATIONS - PROVIDE AN ENERGY | | SUBMITTAL. | | | | THE PROJECT QUALIFIES AS A RENOVATION AS THE PROPOSED | | COST EXCEEDS 30% OF THE VALUE OF THE EXISTING | | STRICTURE. | | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | STORIES. | | | | FBCE-103.2.1.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM 402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | FBCE-103.2.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM 405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | PREVIOUS COMMENTS: | | | | PROVIDE STRUCTURAL DETAILS FOR ALTERATIONS OF OPENINGS | | TO ACCOMODATE THE INSTALLATION OF NEW WINDOW AND DOOR | | PRODUCTS, AS MAY BE NECESSARY. | | | | ADDITIONALLY, THE PLAN NOTES ARE IN CONFLICT WITH THE | | PRODUCT APPROVALS AND NOTE 08.1 & 08.2 ON SHEET A-1.1 | | INDICATING IMPACT RESISTANT WINDOWS, SPECIFYING NON | | IMPACT, AND ALSO PROVIDING STORM PANELS. PLEASE FURTHER | | EVALUATE THESE ISSUES AND SPECFY WHAT IS SPECIFICALLY | | PROPOSED. | | | | THE DESIGN PRESSURES PROVIDED SHOULD BE SPECIFIC TO | | EACH OPENING. YOU HAVE APPARENTLY PROVIDED A ONLY | | GENERAL ZONE INFORMATION. | | | | | | | | | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-04 |
Time |
06:10 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-04 |
Time |
05:24 |
Sent To |
|
|
Notes |
2015-06-04 06:43:17 | 1ST REVIEW: FBC 2010 | | | | FBC 107 PLEASE PROVIDE ADDITIONAL DETAILS AS FOLLOWS: | | | | STRUCTURAL DETAIL FOR ALTERATIONS OF OPENINGS TO | | ACCOMODATE THE INSTALLATION OF NEW WINDOW AND DOOR | | PRODUCTS, AS MAY BE NECESSARY. | | | | THE ARCHITECTS LETTER OF 4/17/15 INDICATES FL 15227-68M | | WILL BE USED AS AN EXTERIOR SWING DOOR. THE PROVIDED | | DOOR PRODUCT INFORMATION IS BY A MANUFACTURER | | INCONSISTENT WITH THE ONE FOUND UNDER THIS NUMBER AT | | HTTPS://FLORIDABUILDING.ORG/PR/PR_DEFAULT.ASPX | | | | THE ARCHITECTS LETTER OF 4/17/15 INDICATES FL 13578-R1 | | WILL BE USED FOR STEEL SHUTTERS. THE PRODUCT | | INFORMATION IS NOT PROVIDED. | | | | NOTE: IT MAY BE ADVISABLE FOR THE DESIGNER OR A | | CONSULTANT ENGINEER TO REVIEW THE WINDOW AND DOOR | | PRODUCTS FURTHER AND PROVIDE ADDITION ANALYSIS AS TO | | DESIGN PRESSURES AND TO PROVIDE AN INSTALLATION | | SCHEDULE FOR THE SHUTTERS. | | YOU MAY WISH TO UTILIZE THE SCHEDULE FOUND AT: HTTP://W | | PB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/2013/09/ | | SCHEDULE_FOR_INSTALLATION.PDF | | | | PLEASE INDICATE THE METHOD INTENDED FOR COMPLIANCE WITH | | FBC-R311.1 AS TO EGRESS WHEN THE BUILDING IS SHUTTERED. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-12-09 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-12-09 |
Time |
08:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2015-10-22 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-10-22 |
Time |
19:38 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-10-22 |
Time |
16:42 |
Sent To |
I |
|
Notes |
2015-10-22 19:39:18 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE 2008 EDITION | | OF THE NEC, (NATIONAL ELECTRICAL CODE); THE FBC, | | (FLORIDA BUILDING CODE) 2010, AS APPLICABLE AND BELOW | | ARE THE DEFICIENCIES NOTED. | | 1. GENERAL NOTES REFERENCE TO THE 2010 NEC SHALL BE | | CORRECTED AS IT NEVER EXISTED. THE APPLICABLE CODE FOR | | THIS PROJECT IS THE 2008 EDITION. | | 2. THE SHEET INDEX MAKES REFERENCE TO SHEET E1.0 FOR | | THE ELECTRIC WHICH IS NOT PROVIDED, YET SUBMITTED SHEET | | E2.1 IS NOT MENTIONED. CORRECT ACCORDINGLY. | | 3. PER NEC 210.70)(A) EXCEPTION AUTOMATIC LIGHTING | | CONTROL IS REQUIRED FOR THE EXTERIOR STAIRWAYS. | | 4. THE WORD ?ROMEX? AS USED IN NOTE 26.3 IS TO IDENTIFY | | A TYPE OF CABLE. ROMEX IS A BRAND NAME AND NOT A TYPE | | OF CABLE; REFER TO CABLE TYPES ?NM?, ?NMC? OR ?NMS?. | | 5. NOTE 26.4 DICTATES KITCHEN COUNTER SPACING AT 36? | | CENTER CONTRARY TO NEC 210.52(C) REQUIREMENTS. CORRECT | | NOTE ACCORDINGLY. | | 6. SMOKE DETECTOR IS REQUIRED INSIDE THE GARAGE | | APARTMENT. | | 7. ARC-FAULT PROTECTION IS ERRONEOUSLY ONLY ADDRESSED | | FOR SMOKE DETECTOR CIRCUITS ON THE PLANS. ARC-FAULT | | PROTECTION REQUIREMENTS APPEAR IN NEC 210.12. | | 8. ALL DWELLING RECEPTACLES SHALL BE LISTED | | TAMPER-RESISTANT ?TR? PER NEC 406.11. | | 9. ALL OUTLETS IN WET LOCATIONS SHALL BE LISTED | | WEATHER-RESISTANT ?WR? AS INDICATED IN NEC 406.8. | | 10. ALL CEILING OUTLET BOXES SHALL BE LISTED TO SUPPORT | | 50#?S AS PER NEC 314.27. | | 11. DWELLING UNIT RECEPTACLES SHALL BE SPACED AS | | INSTRUCTED IN NEC 210.52. AS SUCH YOU ARE MISSING | | OUTLETS IN THE FAMILY ROOM, BEHIND THE FIREPLACE, | | LIVING ROOM, BEDROOMS I & II. | | 12. PORCH LIGHT SHALL BE CONTROLLED VIA A 3 WAY SWITCH | | BY ENTRY WAY. | | 13. BEDROOM CORRIDOR SHALL BE PROPERLY ILLUMINATED AND | | SWITCHED PREFERABLY WITH A 3 OR 4 WAY SWITCHES. | | 14. IF THE OUTLET INSIDE THE CLOSET IN BEDROOM II IS TO | | BE INTENDED FOR THE CONNECTION OF ANY EQUIPMENT, NEC | | 210.70 REQUIRES THAT THERE BE A LIGHT CONTROLLED BY A | | WALL SWITCH FOR THAT ROOM. | | 15. KITCHEN COUNTER OR PENINSULA OUTLETS SHALL BE AS | | DICTATED IN NEC 210.52 (C); THE PENINSULA SHALL HAVE AN | | OUTLET AS REQUIRED. | | 16. THERE SHALL BE A GFI ?WR? OUTLET IN FRONT OF THE | | DWELLING PER NEC 210.52(E)(1). | | 17. YOU SHALL SHOW THE REQUIRED LAUNDRY CIRCUIT 19 ON | | THE FLOOR PLAN. | | 18. YOU SHALL PROVIDE ACCURATE AND SITE SPECIFIC FEEDER | | DIAGRAM AND LOAD CALCS SHOW PROPER CONDUCTOR AND GROUND | | CONDUCTOR SIZING FOR THE COMPLETE SERVICE AS MANDATED | | BY NEC 215.5. | | 19. THE CONNECTED LOAD AS INDICATED EXCEEDS THE RATING | | OF THE MAIN CIRCUIT BREAKER AND BUS BAR OF PANEL P1. | | THE PLANS SHALL BE REVISED TO ADDRESS THE HEREIN | | MENTIONED ITEMS; ONCE CORRECTED SHALL BE RESUBMITTED | | FOR ANOTHER REVIEW. WHEN RESUBMITTING, YOU ARE REQUIRED | | TO PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM ALONG | | WITH THE STANDARD CITY RE-SUBMITTAL FORM. PLEASE, | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE SUBMITTAL | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARISON. CLOUDING THE CHANGES WILL BE GREATLY | | APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-07-14 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-07-14 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-07-11 |
Time |
13:26 |
Sent To |
|
|
Notes |
2015-07-14 12:51:04 | 7/14/2015 | | PROJECT: 347 PLYMOTH | | PERMIT#: 15050879 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC, | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER ONE, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 2ND ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | COMMENTS: | | | | 1) THE SERVICE RISER PROVIDE IS NOT COMPLIANT. | | DISCONNECTS SHALL BE GROUPED. NEC 230.72. YOU INDICATE | | PANEL P1 TO BE LOCATED INSIDE MAIN HOUSE NEW LAUNDRY | | ROOM AND P2 TO BE LOCATED IN THE DETACHED GARAGE | | BUILDING. | | | | 2) INDICATE THE LOCATION OF THE ELECTRICAL SERVICE | | METER. | | | | 3) INDICATE THE SIZE AND CONTENTS OF THE EXISTING | | SERVICE RACEWAY BETWEEN THE METER AND PANEL P1. YOUR | | NOTES 26.1 ON PAGE E-2.1 INDICATE THAT YOU PROPOSE A | | NEW ELECTRICAL SERVICE WITH MAIN DISCONNECT THIS | | CONFLICTS WITH YOUR RISER DIAGRAM. | | CLARIFIFICATION REQUIRED. YOU INDICATE THE METER AND | | SERVICE ENTRANCE CONDUCTORS TO PANEL P1 ARE EXISTING | | AND YET PANEL P1 IS A NEW PANEL AND ACCORDING TO PAGE | | A-1.0 IT IS IN A NEW LOCATION. | | YOU ALSO INDICATE PANEL P2 IS FED THROUGH P1 HOWEVER | | THERE IS NO INDICATION OF AN OCPD IN PANEL P1 TO FEED | | P2. IN ADDITION THE NOTES ON PAGE E-2.1 INDICATE A NEW | | UNDERGROUND TO THE EXISTING SERVICE. THERFORE THE | | SERVICE RISER AND SITE/FLOOR PLAN NEED CLARIFICATION. | | | | 4) INDICATE ALL REQUIRED SMOKE DETECTORS. YOU HAVE | | INDICATED SMOKE DETECTORS OUTSIDE OF THE SLEEPING ROOMS | | BUT NOT INSIDE. ALSO GIVE CAREFUL CONSIDERATION TO THE | | REQUIREMENTS IN THE FBC-R 315 CARBON MONOXIDE | | DETECTORS. WHEN ALTERATIONS, REPAIRS, OR ADDITIONS | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. | | FBC-RESIDENTIAL 314 AND 315. | | | | 5) PROVIDE CLARIFICATION AT THE ELECTRICAL PANEL. EVERY | | CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC | | PURPOSE OR USE. NEC 408.4 SPECIFICALLY THE WATER HEATER | | IN BOTH PANELS. THE SYSTEM VOLTAGE AND LOAD SHOULD BE | | CLEAR. YOU HAVE INDICATED THE WIRE SIZE AND IN MOST | | CASES THE NUMBER OF POLES USED BUT THE OCPD SIZE HAS | | NOT BEEN INDICATED. PLEASE CLARIFY. | | | | 6) PROVIDE DISCONNECTS AT AHU'S NEC 440.14 | | | | 7) INDICATE GFI AS GEQUIRED IN THE KITCHEN FOR | | COUNTERTOP OUTLETS. NEC 210.8(6) | | | | 8) VERIFY CLEARANCES REQUIRED FOR ELECTRICAL PANEL AND | | ELECTRICAL EQUIPMENT REQUIRING SERVICE. NEC 110.26 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | | 2015-07-11 13:26:23 | 2ND REVIEW: FBC 2010 | | | | UNDER REVIEW - SENT TO DAVID HAYES | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-04 |
Time |
05:49 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-04 |
Time |
05:49 |
Sent To |
|
|
Notes |
2015-06-04 05:51:02 | 1ST REVIEW: FBC 2010 | | | | FBC 107 PROVIDE ELECTRIC SERVICE RISER WITH WIRE SIZES, | | CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE LOAD | | CALCULATIONS & PANEL SCHEDULES PER THE ARCHITECTS | | DIRECTION ON MEP-2.0. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
P |
Date |
2015-12-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-12-11 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-12-11 |
Time |
10:23 |
Sent To |
|
|
Notes |
2015-12-11 10:30:00 | PLANS DO NOT ADDRESS PREVIOUS COMMENTS FOR WINDOWS TO | | MATCH ORIGINAL STYLE. | 2015-12-11 10:23:59 | SEE NOTE FROM PREVIOUS REVIEW....WINDOWS TO MATCH | | ORIGINAL. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2015-10-06 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-10-06 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-10-06 |
Time |
11:14 |
Sent To |
|
|
Notes |
2015-10-06 11:17:51 | NEW WINDOWS TO MATCH ORIGINAL (BELIEVE 4/1) AS | | DISCUSSED WITH OWNER. QUESTIONS, CONTACT FRIEDERIKE | | MITTNER AT 822-1457. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2015-07-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-07-10 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-07-10 |
Time |
15:29 |
Sent To |
|
|
Notes |
2015-07-10 15:32:18 | DOORS TO GARAGE SHALL BE SOLID OR CARRIAGE WITH GLASS | | AT TOP (NOT FRENCH) |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2015-06-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-06-01 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-06-01 |
Time |
15:31 |
Sent To |
|
|
Notes |
2015-06-01 15:32:29 | THE DOUBLE DOORS IN THE ACCESSORY STRUCTURE SHALL | | REMAIN IN THE EXISTING GARAGE DOOR OPENING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2015-12-11 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-12-11 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-12-02 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-10-22 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-10-22 |
Time |
19:39 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-09-22 |
Time |
12:31 |
Sent To |
|
|
Notes |
2015-10-22 19:40:37 | 10/22/15 FAILED ELECTRICAL REVIEW AS NOTED. PER SAK | | PLACED ON HIS DESK. | 2015-09-22 12:32:00 | RESUB ROUTED TO FMITTNER THROUGH SGRAHAM'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-14 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-07-14 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-24 |
Time |
19:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-04 |
Time |
06:43 |
Rev Time |
|
Received By |
skennedy |
Date |
2015-05-20 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2015-07-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-11 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-11 |
Time |
13:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2015-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-04 |
Time |
05:36 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-04 |
Time |
05:36 |
Sent To |
|
|
Notes |
2015-06-04 05:39:34 | 1ST REVIEW: FBC 2010 | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-12-09 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-12-09 |
Time |
08:14 |
Sent To |
|
|
Notes |
2015-12-09 08:21:18 | PROVISIONALLY APPROVED PROVIDE A SIZING CALCULATION | | UNLESS HOME IS A CONTRIBUTING HISTORIC STRUCTURE. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2015-10-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-10-17 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-10-17 |
Time |
17:53 |
Sent To |
P |
|
Notes |
2015-10-17 17:54:52 | 3RD REVIEW: FBC 2010 | | | | FBC-EC 403.2.5 PROVIDE A SIZING CALCULATION | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2015-07-13 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-13 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-11 |
Time |
13:26 |
Sent To |
|
|
Notes |
2015-07-11 13:26:47 | 2ND REVIEW: FBC 2010 | | | | FBC 107 _ PROVIDE AN ENERGY SUBMITTAL. | | FBC- 107.3.5.3 ? PROVIDE A MECHANICAL PLAN TO SHOW | | SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R | | M15. | | PROVIDE AN EQUIPMENT SCHEDULE. | | FBC-EC 403.2.5 PROVIDE A SIZING CALCULATION | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-04 |
Time |
05:44 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-04 |
Time |
05:44 |
Sent To |
|
|
Notes |
2015-06-04 05:49:26 | 1ST REVIEW: FBC 2010 | | | | FBC 107 PROVIDE A MECHANICAL PLAN PER THE ARCHITECTS | | DIRECTION ON MEP-2.0. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-12-09 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-12-09 |
Time |
08:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2015-10-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-10-19 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-10-19 |
Time |
09:36 |
Sent To |
|
|
Notes |
2015-10-19 09:41:56 | | | | | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | | | | | 1. SHEET MP-2.0 RISER DIAGRAM FOR WASHING MACHINE IS | | MISSING PLEASE PROVIDE. | | PER WPB AMEND. TO FBC SEC107.3.5.3(11) | 2015-10-17 18:10:19 | ASSIGNED TO GEORGE JOHNSON |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-07-13 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-13 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-11 |
Time |
13:26 |
Sent To |
|
|
Notes |
2015-07-11 13:27:16 | 2ND REVIEW: FBC 2010 | | | | FBC 107 PROVIDE AN ACCURATE PLUMBING RISER TO INDICATE | | THE ALTERATIONS AND ADDITIONS OF FIXTURES. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-04 |
Time |
05:51 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-04 |
Time |
05:51 |
Sent To |
|
|
Notes |
2015-06-04 05:52:56 | 1ST REVIEW: FBC 2010 | | | | FBC 107 PROVIDE A PLUMBING RISER TO INDICATE THE | | ALTERATIONS AND ADDITIONS OF FIXTURES CONSISTENT WITH | | THE ARCHITECTS PLAN ON MEP-2.0. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2015-12-09 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-12-09 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-12-09 |
Time |
08:15 |
Sent To |
|
|
Notes |
2015-12-09 08:16:53 | ROOFING WORK WILL REQUIRE AN ADDITIONAL SUBMITTAL AS TO | | ANY PROPOSED NEW ROOF COVERING. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2015-12-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-12-11 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-12-11 |
Time |
10:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-07-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-07-10 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-07-10 |
Time |
15:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-06-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-06-01 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-06-01 |
Time |
15:32 |
Sent To |
|
|
Notes |
2015-06-01 15:32:56 | THE ACCESSORY UNIT IS NOT PERMITTED TO HAVE A KITCHEN | | FACILITY PER THE ZONING ORDINANCE NOR BE UTILIZED AS A | | SEPARATE LIVING UNIT. |
|
|