Plan Review Details - Permit 15050849
Plan Review Stops For Permit 15050849
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-06-21 Cont ID  
Sent By jwitmer Date 2015-06-21 Time 10:12 Rev Time 0.00
Received By jwitmer Date 2015-06-21 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-05-21 Cont ID  
Sent By jwitmer Date 2015-05-21 Time 17:28 Rev Time  
Received By jwitmer Date 2015-05-21 Time 17;01 Sent To  
Notes
2015-05-21 17:16:19 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15050849
 ADD: 400 N. FLAGLER DR. # 1403
 CONT: JOHN ROSSI CONSTRUCTION
 TEL: (561)659-5505
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURSDAY MAY 21/ 2015
 ACTION: DENIED
  
 THE SHEET A-1 INDICATES REPLACE FINISHES IN ALL ROOMS.
 PLEASE COMPLY WITH THE FOLLOWING CODE REQUIREMENTS:
  
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION
 1A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 703.4 NONCOMBUSTIBILITY TESTS.
 THE TESTS INDICATED IN SECTIONS 703.4.1 AND 703.4.2
 SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF BUILDING
 MATERIALS AS SET FORTH IN SECTIONS 602.2, 602.3 AND
 602.4 IN TYPE I, II, III AND IV CONSTRUCTION. THE TERM
 ?NONCOMBUSTIBLE? DOES NOT APPLY TO THE FLAME SPREAD
 CHARACTERISTICS OF INTERIOR FINISH OR TRIM MATERIALS. A
 MATERIAL SHALL NOT BE CLASSIFIED AS A NONCOMBUSTIBLE
 BUILDING CONSTRUCTION MATERIAL IF IT IS SUBJECT TO AN
 INCREASE IN COMBUSTIBILITY OR FLAME SPREAD BEYOND THE
 LIMITATIONS HEREIN ESTABLISHED THROUGH THE EFFECTS OF
 AGE, MOISTURE OR OTHER ATMOSPHERIC CONDITIONS.
  
 703.4.1 ELEMENTARY MATERIALS.
 MATERIALS REQUIRED TO BE NONCOMBUSTIBLE SHALL BE TESTED
 IN ACCORDANCE WITH ASTM E 136.
  
 703.4.2 COMPOSITE MATERIALS.
 MATERIALS HAVING A STRUCTURAL BASE OF NONCOMBUSTIBLE
 MATERIAL AS DETERMINED IN ACCORDANCE WITH SECTION
 703.4.1 WITH A SURFACING NOT MORE THAN 0.125 INCH (3.18
 MM) THICK THAT HAS A FLAME SPREAD INDEX NOT GREATER
 THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL
 723 SHALL BE ACCEPTABLE AS
 NONCOMBUSTIBLE MATERIALS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-06-23 Cont ID  
Sent By rlecky Date 2015-06-23 Time 11:00 Rev Time 0.00
Received By rlecky Date 2015-06-23 Time 10:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-06-04 Cont ID  
Sent By rlecky Date 2015-06-04 Time 12:37 Rev Time 0.00
Received By rlecky Date 2015-06-04 Time 12:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-06-24 Cont ID  
Sent By pleduc Date 2015-06-24 Time   Rev Time 0.00
Received By pleduc Date 2015-06-24 Time 15:58 Sent To M
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-05-27 Cont ID  
Sent By pleduc Date 2015-05-27 Time   Rev Time 0.00
Received By pleduc Date 2015-05-27 Time 09:24 Sent To  
Notes
2015-05-27 09:26:03THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE.
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-08 Cont ID  
Sent By ccole Date 2015-07-08 Time 10:54 Rev Time 0.00
Received By ccole Date 2015-06-15 Time   Sent To  
Notes
2015-06-15 11:32:27B26

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-12 Cont ID  
Sent By skennedy Date 2015-06-08 Time 11:09 Rev Time  
Received By skennedy Date 2015-05-20 Time   Sent To  
Notes
2015-05-21 15:16:31B26

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-07-08 Cont ID  
Sent By ccole Date 2015-07-08 Time 10:54 Rev Time 0.00
Received By ccole Date 2015-07-08 Time 10:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-06-08 Cont ID  
Sent By ccole Date 2015-06-08 Time 09:30 Rev Time 0.00
Received By ccole Date 2015-06-08 Time 09:30 Sent To  
Notes
2015-06-08 09:38:121ST REVIEW: FBC 2010 MECHANICAL
  
 1) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 RECIRCULATION EXHAUST SYSTEM- SECTION M1593.4, AND
 TABLE M1507.3 FBC-10 RESIDENTIAL.
 2) CLARIFY IF ANY NEW DUCTS OR DUCT RELOCATIONS, OR NEW
 DIFFUSER AND RETURN AIR GRILL INSTALLATIONS ARE PART OF
 THE SCOPE OF WORK.
  
 CHRISTOPHER COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-07-01 Cont ID  
Sent By tklarge Date 2015-07-01 Time 06:25 Rev Time 0.00
Received By tklarge Date 2015-07-01 Time 06:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-06-04 Cont ID  
Sent By tklarge Date 2015-06-04 Time 04:29 Rev Time 0.00
Received By tklarge Date 2015-06-04 Time 04:07 Sent To  
Notes
***NONE***