Plan Review Details - Permit 15050843
Plan Review Stops For Permit 15050843
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-07-05 Cont ID  
Sent By shill Date 2015-07-05 Time 14:58 Rev Time 0.00
Received By shill Date 2015-07-05 Time 14:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-06-04 Cont ID  
Sent By shill Date 2015-06-04 Time 10:24 Rev Time 0.00
Received By shill Date 2015-06-04 Time 10:24 Sent To FIRE
Notes
2015-06-04 10:26:58****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE MSDS PAGE PROVIDED INCLUDES THREE DIFFERENT
 PRODUCTS. FOR THE FLOORING UNDERLAYMENT, PROVIDE THE
 FOLLOWING THREE TEST REPORTS:
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST,
 PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED
 THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE
 GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL
 NOT BE ALTERED.
  
 PLEASE PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART
 OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN
 DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW
 IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT
 BELOW WILL NOT BE ALTERED.
  
 PLEASE PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM
 E 84 OR UL 723.
  
 IF THE PRODUCT PROPOSED IS WHISPER MAT CS, THIS CAN BE
 INDICATED (CIRCLED) ON THE MSDS AND TEST REPORTS DO NOT
 NEED TO BE PROVIDED AS THIS DEPARTMENT HAS THEM ON
 FILE. IF ANOTHER PRODUCT IS SELECTED, PROVIDE THE THREE
 REQUIRED TEST REPORTS.
  
 2. VALUE TO INCLUDE THE VALUE OF LABOR, MATERIALS,
 OVERHEAD, AND PROFIT. PROVIDE A COPY OF THE CONTRACT
 FOR THIS JOB, FBC 109.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-06-04 Cont ID  
Sent By pleduc Date 2015-06-04 Time   Rev Time 0.00
Received By pleduc Date 2015-06-04 Time 15:52 Sent To PC
Notes
2015-06-04 15:58:05THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 MAINTAIN FIRE SPRINKLER AND FIRE ALARM SYSTEM, DEVICES
 AND EQUIPMENT. ANY WORK OR DAMAGE TO LIFE SAFETY
 DEVICES SHALL BE REPAIRED BY A LIFE SAFETY CONTRACTOR
 UNDER SEPARATE SHOP DRAWINGS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-05 Cont ID  
Sent By shill Date 2015-07-05 Time 14:58 Rev Time 0.00
Received By shill Date 2015-06-16 Time 11:40 Sent To  
Notes
2015-06-16 11:40:18TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-04 Cont ID  
Sent By tlarge Date 2015-06-04 Time   Rev Time  
Received By pleduc Date 2015-05-20 Time   Sent To P
Notes
2015-06-04 10:27:206/4 TO FIRE BOX
  
2015-05-21 16:04:16T.LARGE'S DESK

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-05-23 Cont ID  
Sent By pleduc Date 2015-06-04 Time 15:58 Rev Time 0.00
Received By tklarge Date 2015-05-23 Time 10:50 Sent To  
Notes
***NONE***