2015-07-20 12:53:49RESIDENTIAL (R3) RENOVATIONS, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC
  
 1- ENGINEER OF RECORD TO SIGN AND SEAL BOTH SETS OF
 DRAWINGS. ONLY ONE WAS SIGNED AND SEALED. CHAPTER 471
 F.S.
  
 2- THIS IS NOT ALTERATION LEVEL 2 AS SPECIFIED ON THE
 PROJECT DATA ON SHEET C-1. THIS IS ALTERATION LEVEL 3.
 SEC. 405 OF 2010 FBC-EXISTING BUILDING. REVISE AS
 REQUIRED.
  
 3- SHEET D-1:
 A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE FIRE SEPARATION AS REQUIRED BY SEC.
 803.2 OF 2010 FBC-EXISTING BUILDING AND SEC. R302.3 OF
 2010 FBC-RESIDENTIAL.
  
 B) INFORMATION SHOWN ON TENANT SEPARATION FLOOR SECTION
 DOESN'T MATCH INFORMATION SHOWN ON THE EXISTING TYPICAL
 WALL SECTION. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1
 CITY AMENDMENTS. NOTE: LOOK AT THE GA FILE FOR CORRECT
 INFORMATION FOR THE SELECTED FIRE RATED ASSEMBLY AND
 REVISE DETAILS ACCORDINGLY. ALSO, TENANT SEPARATION
 DETAIL IS FOR ONE STORY. THIS IS A TWO STORY HOUSE.
 REVISE AS REQUIRED TO MATCH ACTUAL CONDITIONS.
  
 C) EXISTING TYPICAL WALL SECTION CALLS FOR "EXISTING
 TILE ROOF". THERE IS NOT TILE ROOF ON THIS HOUSE.
 REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 4- WINDOW MULLION PRODUCT APPROVAL FL9520-R4 SUBMITTED:
 A) CLEARLY IDENTIFY SIZE OF MULLIONS TO BE USED TO
 VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC.
 R301.
  
 B) DRAWINGS ARE TOO SMALL. THERE ARE TWO SHEETS OF
 DRAWINGS INSERTED ON EACH PAGE. PROVIDE ONE SHEET ON
 EACH PAGE SO DRAWINGS ARE LARGE ENOUGH TO BE READ. SEC.
 107.2.1.4 CITY AMENDMENTS.
  
 5- ALL PRODUCT APPROVALS TO BE REVIEWED AND APPROVED IN
 WRITING (NOT SIGNING AND SEALING) BY THE ENGINEER OF
 RECORD. SEC. 107.3.4.1 CITY AMENDMENTS. NOT ALL THE
 PRODUCT APPROVALS SUBMITTED HAVE THE ENGINEER'S REVIEW
 STAMP.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REPLACE AND REMOVE ANY REVISED DRAWING.
 SUBMIT OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-07-21 Cont ID  
Sent By albarran Date 2015-07-21 Time 13:15 Rev Time 0.00
Received By albarran Date 2015-07-21 Time 10:10 Sent To M
Notes
2015-07-21 13:16:23APPROVED W/PROVISO: ELECTRICAL PROVISO TO PERMIT
 15050404
  
 PER NEC 210.70 (A)(2) STAIRWAY ILLUMINATION AND
 ADEQUATE SWITCHING IS REQUIRED. AUTOMATIC SWITCH IS
 PERMITTED.
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-07-20 Cont ID  
Sent By fmittner Date 2015-07-20 Time 10:25 Rev Time 0.00
Received By fmittner Date 2015-07-20 Time 10:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-09-02 Cont ID  
Sent By jgomez Date 2015-09-02 Time 09:36 Rev Time 0.00
Received By jgomez Date 2015-08-13 Time 16:17 Sent To  
Notes
2015-08-13 16:17:26RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-24 Cont ID  
Sent By jgomez Date 2015-07-24 Time 14:45 Rev Time 0.00
Received By jgomez Date 2015-05-12 Time 16:16 Sent To  
Notes
2015-05-13 16:17:19SENT TO R32 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-09-02 Cont ID  
Sent By jgomez Date 2015-09-02 Time 09:36 Rev Time 0.00
Received By jgomez Date 2015-09-02 Time 09:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-07-24 Cont ID  
Sent By jgomez Date 2015-07-24 Time 14:43 Rev Time 0.00
Received By jgomez Date 2015-07-24 Time 14:41 Sent To  
Notes
2015-07-24 14:45:16RESIDENTIAL (R3) RENOVATIONS, MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC
  
 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS (2
 COPIES) AS REQUIRED BY SEC. M1401.3 OF 2010
 FBC-RESIDENTIAL
  
 2- EQUIPMENT LISTED ON THE MECHANICAL PLAN TO MATCH
 EQUIPMENT LISTED ON THE EQUIPMENT SIZING CALCULATIONS
 REQUIRED ON ITEM #1 ABOVE. SEC. 107.3.5.3(10) CITY
 AMENDMENTS.
  
 3- INFORMATION SHOWN ON THE AIR COOLED CONDENSING UNIT
 SLAB MOUNTED DETAIL IS NOT LEGIBLE. REVISE AS REQUIRED.
 SEC. 107.2.1.4 CITY AMENDMENTS.
  
 4- THE DESIGN CRITERIA SPECIFIED ON THE MECHANICAL
 PLANS IS INCORRECT. ENGINEER OF RECORD TO REVISE AS
 REQUIRED. SEC. R301 OF 2020 FBC-RESIDENTIAL.
  
 5- TRANSFER GRILLS ON FIRST FLOOR MECHANICAL PLAN ARE
 LOCATED IN THE DOOR. THE TRANSFER GRILLS NEED TO BE
 LOCATED ON THE WALL NOT IN THE DOOR A SHOWN ON SECOND
 FLOOR MECHANICAL PLAN. REVISE AS REQUIRED. SEC. M1602.4
 OF THE 200 FBC-RESIDENTIAL.
  
 6- 1ST FLOOR MECHANICAL PLAN: CLARIFY TYPE AND SIZE OF
 SUPPLY AIR DUCT. IS IT FLEXIBLE OR DUCTED FIBERGLASS.
 FOR EXAMPLE PLANS SPECIFY 6" DIAMETER SUPPLY BUT IT'S
 SHOWN AS RECTANGULAR DUCT. SECOND FLOOR IS SHOWN
 CORRECTLY. SEC. 107.2.1 CITY AMENDMENTS.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REPLACE AND REMOVE ANY REVISED DRAWING.
 SUBMIT OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-08-15 Cont ID  
Sent By tklarge Date 2015-08-15 Time 05:11 Rev Time 0.00
Received By tklarge Date 2015-08-15 Time 04:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-06-13 Cont ID  
Sent By tklarge Date 2015-06-13 Time 02:33 Rev Time 0.00
Received By tklarge Date 2015-06-13 Time 01:40 Sent To  
Notes
2015-06-13 02:27:231) SUBMIT A WATER RISER DIAGRAM FOR REVIEW. WPB
 AMEND.TO 2010 FBC SEC. 107.3.5..
 2) ONLY ONE SET OF PLANS BEARS THE SEAL AND SIGNATURE
 OF THE DESIGNER OF RECORD. SUBMIT TWO SETS OF PLANS
 THAT BEAR THE SEAL AND SIGNATURE OF THE DESIGN
 PROFESSIONAL OF RECORD. FL. ADMIN. CODE RULE
 61G15-23.002
 3) SHT. C-1 - GENERAL NOTES - REFERENCE IS MADE TO THE
 STANDARD PLUMBING CODE.THE CODE IN EFFECT IS THE 2010
 FLORIDA BUILDING CODE - PLUMBING. WPB AMEND.TO 2010 FBC
 SEC. 102.2. R EVISE THE NOTE.
 4) SHT. D-1 - SIZE ALL SECTIONS OF THE SANITARY RISER
 DIAGRAM.(2ND FLOOR RISER AND ALL LOOP VENTS.) WPB
 AMEND. TO 2010 FBC SEC. 107.3.5.3.
 5)THE LAYOUT OF THE SANITARY RISER DOES NOT MATCH THE
 FLOOR PLAN. THE LOCATION OF THE FIXTURES DO NOT
 CORRELATE WITH THE FLOOR PLAN.SEE THE BATH NEAR THE
 LAUNDRY ROOM AND THE BATH BETWEEN BEDROON #1 & #2.
 6) THE RISER SHOWS ONE LAVATORY FOR THE BATH BETWEEN
 BEDROOMS # 1 & #2 AND THE FLOOR PLAN SHOWS TWO.
 CLARIFY.
 7) THE WATER HEATER ON THE SECOND FLOOR REQUIRES A PAN
 UNDERNEATH AND A PAN DRAIN THAT SHALL DISCHARGE TO THE
 EXTERIOR. THE PAN AND PAN DRAIN SHALL COMPLY WITH 2010
 FBCR SEC.P2801.5 THRU P2801.5.2.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-07-10 Cont ID  
Sent By aaponte Date 2015-07-10 Time 16:08 Rev Time 0.00
Received By aaponte Date 2015-07-10 Time 16:08 Sent To  
Notes
2015-07-10 16:09:27PROVISO: ONLY 2 UNITS ALLOWED IN THIS PROPERTY. ROOMING
 HOUSE NOT ALLOWED.
 FRONT SETBACK SHALL BE COVERED WITH PLANT MATERIAL.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved