Plan Review Details - Permit 15050177
Plan Review Stops For Permit 15050177 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2015-09-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-09-10 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-09-10 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-08-26 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-08-24 |
Time |
|
Sent To |
|
|
Notes |
2015-08-24 16:20:31 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15050177 | | ADD: 1152 OKEECHOBEE RD | | CONT: ABACOA CONSTRUCTION | | TEL: (561)722-3890 | | E-MAIL: [email protected] | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: WEDNESDAY JULY 22/ 2015 | | ACTION: DENIED | | | | 1-3) COMPLIED. | | | | 4) THE RAISED PLATFORM 20 INCHES ABOVE THE FLOOR DOES | | INDICATE VERTICAL ACCESSIBILITY WILL BE ACHIEVED BY A | | RAMP. THE PLANS INDICATE 20 FEET OF RUN, BUT THERE IS A | | LANDING AT THE TOP OF THE RAMP WHERE A 90 DEGREE TURN | | MUST BE MADE. PLEASE SHOW COMPLIANCE WITH: | | | | 4A) 2010 FBC-ACCESSIBILITY 405.7.4 CHANGE IN DIRECTION. | | RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS | | SHALL HAVE A CLEAR LANDING 60 INCHES (1525 MM) MINIMUM | | BY 60 INCHES (1525 MM) MINIMUM. | | | | 4B) ACCESSIBILITY 405.8 HANDRAILS. RAMP RUNS WITH A | | RISE GREATER THAN 6 INCHES (150 MM) SHALL HAVE | | HANDRAILS COMPLYING WITH 505. | | 505.3 CONTINUITY. | | HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF | | EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON | | SWITCHBACK OR DOGLEG STAIRS AND RAMPS SHALL BE | | CONTINUOUS BETWEEN FLIGHTS OR RUNS. | | | | 505.4 HEIGHT. TOP OF GRIPPING SURFACES OF HANDRAILS | | SHALL BE 34 INCHES (865 MM) MINIMUM AND 38 INCHES (965 | | MM) MAXIMUM VERTICALLY ABOVE WALKING SURFACES, STAIR | | NOSINGS, AND RAMP SURFACES. HANDRAILS SHALL BE AT A | | CONSISTENT HEIGHT ABOVE WALKING SURFACES, STAIR | | NOSINGS, AND RAMP SURFACES. | | | | 4C) 405.9 EDGE PROTECTION. EDGE PROTECTION COMPLYING | | WITH 405.9.1 OR 405.9.2 SHALL BE PROVIDED ON EACH SIDE | | OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. | | | | | | 5-9) COMPLIED. | | | | 10) THE MECHANICAL PLANS ALSO SHOW WALL LOUVERS AND | | ROOF TOP A/C STANDS. PLEASE PROVIDE COMPLIANCE WITH: | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | WILL REQUIRE PRODUCT APPROVALS: | | (31)(C) WALL LOUVERS | | (G) PRE-ENGINEERED A/C STANDS | | | | 11) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC | | | | 12 ) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-07-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-07-22 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2015-07-22 14:03:08 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15050177 | | ADD: 1152 OKEECHOBEE RD | | CONT: ABACOA CONSTRUCTION | | TEL: (561)722-3890 | | E-MAIL: [email protected] | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: WEDNESDAY JULY 22/ 2015 | | ACTION: DENIED | | | | 1-3) COMPLIED. | | | | 4) THE PLATFORM DOES INDICATEVERTICAL ACCESSIBILITY | | WILL BE ACHIEVED BY A PLATFORM LIFT. , PLEASE PROVIDE | | COMPLIANCE WITH THE 2010 FBC-ACCESSIBILITY CODE, | | 201.1.1 VERTICAL ACCESSIBILITYSECTIONS 553.501-553.513, | | F.S., AND THE ADA STANDARDS FOR ACCESSIBLE DESIGN DO | | NOT RELIEVE THE OWNER OF ANY BUILDING, STRUCTURE OR | | FACILITY GOVERNED BY THOSE SECTIONS FROM THE DUTY TO | | PROVIDE VERTICAL ACCESSIBILITY TO ALL LEVELS ABOVE AND | | BELOW THE OCCUPIABLE GRADE LEVEL REGARDLESS OF WHETHER | | THE STANDARDS REQUIRE AN ELEVATOR TO BE INSTALLED IN | | SUCH BUILDING, STRUCTURE OR FACILITY. PLEASE PROVIDE | | THE MANUFACTURERS LIFT DESIGN CRITERIA. | | | | PLATFORM LIFTS ARE TO MEET THE ASME A18.1 STANDARDS. | | PLEASE SHOW COMPLIANCE WITH 410 PLATFORM LIFTS: | | | | 410.1 GENERAL. | | PLATFORM LIFTS SHALL COMPLY WITH ASME A18.1 (1999 | | EDITION OR 2003 EDITION) (INCORPORATED BY REFERENCE, | | SEE ?REFERENCED STANDARDS? IN CHAPTER 1). PLATFORM | | LIFTS SHALL NOT BE ATTENDANT-OPERATED AND SHALL PROVIDE | | UNASSISTED ENTRY AND EXIT FROM THE LIFT. | | | | 410.2 FLOOR SURFACES. | | FLOOR SURFACES IN PLATFORM LIFTS SHALL COMPLY WITH 302 | | AND 303. | | | | 410.3 CLEAR FLOOR SPACE. | | CLEAR FLOOR SPACE IN PLATFORM LIFTS SHALL COMPLY WITH | | 305. | | | | 410.4 PLATFORM TO RUNWAY CLEARANCE. | | THE CLEARANCE BETWEEN THE PLATFORM SILL AND THE EDGE OF | | ANY RUNWAY LANDING SHALL BE 1 INCH (32 MM) MAXIMUM. | | | | 410.5 OPERABLE PARTS. | | CONTROLS FOR PLATFORM LIFTS SHALL COMPLY WITH 309. | | | | 410.6 DOORS AND GATES. | | PLATFORM LIFTS SHALL HAVE LOW-ENERGY POWER-OPERATED | | DOORS OR GATES COMPLYING WITH 404.3. DOORS SHALL REMAIN | | OPEN FOR 20 SECONDS MINIMUM. END DOORS AND GATES SHALL | | PROVIDE A CLEAR WIDTH 32 INCHES (815 MM) MINIMUM. SIDE | | DOORS AND GATES SHALL PROVIDE A CLEAR WIDTH 42 INCHES | | (1065 MM) MINIMUM. | | | | 5-7) COMPLIED. | | | | 8) 2ND REQUEST. SHEET LS-1 THE DOOR SCHEDULE SHOWS DOOR | | TYPE 1 TO BE A 2'-8" DOORS ARE TO COMPLIANCE FOR FBC-B | | 1008.1.1 AND ACCESS. CODE 404.2.3. | | | | 9) SHEET LS-1 THE PLANS INDICATES THE STORAGE ROOM TO | | BE 425 SQ. FT. THE OVERALL TOTAL SQUARE FOOTAGE GIVEN | | IS 4,000 SQ. FT. OR OVER 10 % OF THE FLOOR AREA THAT | | CREATES A MIXED USE OCCUPANCY. SEE 2010 FBC-B 508.2.1 | | AREA LIMITATIONS. PLEASE REVIEW THE 2010 FBC-B TABLE | | 508.4 DEPENDING IF THE STORAGE ROOM IS A S1 OR S2 THE | | ROOM WILL REQUIRE A 1 HR OR 2 HOUR FIRE SEPARATION, NO | | FIRE SPRINKLERS. | | | | 10) THE MECHANICAL PLANS (M1) ALSO SHOW WALL LOUVERS | | AND ROOF TOP A/C STANDS. PLEASE PROVIDE COMPLIANCE | | WITH: | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | WILL REQUIRE PRODUCT APPROVALS: | | (31)(C) WALL LOUVERS- OUTSIDE AIR | | | | | | 11) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC | | | | 12 ) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-05-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-05-20 |
Time |
11:01 |
Rev Time |
|
Received By |
jwitmer |
Date |
2015-05-19 |
Time |
13:23 |
Sent To |
|
|
Notes |
2015-05-19 16:58:41 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 15050177 | | ADD: 1152 OKEECHOBEE RD | | CONT: ABACOA CONSTRUCTION | | TEL: (561)722-3890 | | E-MAIL: [email protected] | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: TUESDAY MAY 19/ 2015 | | ACTION: DENIED | | | | 1) SHEET LS-1 SHOWS A RAISED PLATFORM AND STAGE. SHEET | | D-1 INDICATES A FLOOR LOADING OF 55 LBS. THIS OCCUPANCY | | IS DECLARED AN A2 NIGHTCLUB. THE MINIMUM UNIFORM | | DISTRIBUTED LOADS FOUND IN FBC-B TABLE 1607.1(4) 125 | | PSF AND THE STAIRS 100 PSF. | | | | 2) SHEET LS-1 THE RAISED PLATFORM WILL NEED TO ALL THE | | RISERS TO BE THE SAME HEIGHT AS REQUIRED IN 2010 FBC-B | | 1009.4.2 RISER HEIGHT AND TREAD DEPTH. STAIR RISER | | HEIGHTS SHALL BE 7 INCHES (178 MM) MAXIMUM AND 4 INCHES | | (102 MM) MINIMUM. 1009.4.4 DIMENSIONAL UNIFORMITY. | | STAIR TREADS AND RISERS SHALL BE OF UNIFORM SIZE AND | | SHAPE. THE TOLERANCE BETWEEN THE LARGEST AND SMALLEST | | RISER HEIGHT OR BETWEEN THE LARGEST AND SMALLEST TREAD | | DEPTH SHALL NOT EXCEED 3/8 INCH (9.5 MM) IN ANY FLIGHT | | OF STAIRS. | | | | 3) DISCREPANCY IN PLAN, THE PLANS INDICATE 3 RISERS, | | FROM THE CITYS VISIT OF SITE AND PICTURES OF THE | | LOCATION THE REISERS ARE NOT UNIFORM AND REVIEW THE | | AMOUNT OF RISERS SHOWN IN PLAN (3) 3 X 7+ 21 INCHES, | | THE PLANS INDICATE THE PLATFORM HEIGHT OF 14 INCHES. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED | | DESCREPANCY IN PLANS. | | | | 4) THE PLATFORM DOES NOT SHOW HOW VERTICAL | | ACCESSIBILITY WILL BE ACHIEVED, PLEASE PROVIDE | | COMPLIANCE WITH THE 2010 FBC-ACCESSIBILITY CODE, | | 201.1.1 VERTICAL ACCESSIBILITYSECTIONS 553.501-553.513, | | F.S., AND THE ADA STANDARDS FOR ACCESSIBLE DESIGN DO | | NOT RELIEVE THE OWNER OF ANY BUILDING, STRUCTURE OR | | FACILITY GOVERNED BY THOSE SECTIONS FROM THE DUTY TO | | PROVIDE VERTICAL ACCESSIBILITY TO ALL LEVELS ABOVE AND | | BELOW THE OCCUPIABLE GRADE LEVEL REGARDLESS OF WHETHER | | THE STANDARDS REQUIRE AN ELEVATOR TO BE INSTALLED IN | | SUCH BUILDING, STRUCTURE OR FACILITY. | | | | 5) THE PLATFORM ALSO IS MISSING A HANDRAIL REQUIRED BY | | FBC-ACCESSIBILITY CODE 504.6 HANDRAILS. STAIRS SHALL | | HAVE HANDRAILS COMPLYING WITH 505. 505.2 WHERE | | REQUIRED. HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF | | STAIRS AND RAMPS. | | | | 505.4 HEIGHT. | | TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 | | INCHES (865 MM) MINIMUM AND 38 INCHES (965 MM) MAXIMUM | | VERTICALLY ABOVE WALKING SURFACES, STAIR NOSINGS, AND | | RAMP SURFACES. HANDRAILS SHALL BE AT A CONSISTENT | | HEIGHT ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP | | SURFACES. | | | | 505.10 HANDRAIL EXTENSIONS. | | HANDRAIL GRIPPING SURFACES SHALL EXTEND BEYOND AND IN | | THE SAME DIRECTION OF STAIR FLIGHTS AND RAMP RUNS IN | | ACCORDANCE WITH 505.10. | | | | 6) THE DJ BOOTH DOES NOT INDICATE IF THIS IS ABOVE THE | | FLOOR OR A PIT BENEATH THE FLOOR LEVEL. SHEET D1 DOES | | NOT GIVE ANY ELEVATIONS NEITHER DOES SHEET LS1. | | 107.2.1.3. | | | | 7) SHEET LS-1 INDICATES ON THE FLOOR PLAN A BAR AND | | CONCESSION AREA WITH COUNTER, PLEASE PROVIDE COMPLIANCE | | WITH THE 2010 FBC-ACCESSIBLITY CODE 904.4 SALES AND | | SERVICE COUNTERS. | | | | 8) SHEET LS-1 PLEASE PROVIDE A DOOR SCHEDULE FOR ALL | | DOORS, COMPLIANCE FOR FBC-B 1008.1.1 AND ACCESS. CODE | | 404.2.3. | | | | SHEET LS-1 PLEASE PROVIDE DIMENSIONS FOR ALL RESTROOMS | | AND SHOWER STALLS TO REVIEW FOR REQUIRED ACCESSIBLITY | | ISSUES, PLEASE PROVIDE ENLARGED FLOOR PLAN & ELEVATION | | OF BATHROOMS AND SHOWERS FOR ACCESSIBILITY. SHOW | | CLEARANCES BETWEEN FIXTURES, GRAB BAR HEIGHTS, BACKING | | FOR GRAB BARS ETC... CHAPTER 6 OF FL ACCESS. CODE. | | | | 9) SHEET LS-1THE PLANS FAIL TO PROVIDE SQ. FEET AREA OF | | OCCUPANCIES AND ACCESSORY OCUPANCIES INDICATE THE | | SQUARE FOOTAGE OF EACH AREA TO SEE IF THIS BUILDING | | QUALIFIES AS A MIXED USE OCCUPANCY BETWEEN THE A2 AND | | STORGE ROOM. SEE FBC-B TABLE 508.4 FOR HOUR RATINGS. | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2015-09-14 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-09-14 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
2015-09-14 14:22:54 | THIRD ELECTRICAL STOP WAS NOT NECESSARY. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-07-21 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-07-21 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-07-20 |
Time |
18:22 |
Sent To |
B |
|
Notes |
2015-07-21 14:22:12 | ELECTRICAL PROVISO: NEC 210.8 RECEPTACLES WITHIN 6' OF | | A SINK SHALL BE GFCI PROTECTED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-05-11 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-05-11 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-05-11 |
Time |
15:58 |
Sent To |
B |
|
Notes |
2015-05-11 19:07:00 | COMMENTSN AND RESPECTIVE COMMENTS FOR ELECTRICAL PLAN | | REVIEW | | PERMIT #: 15050177 | | DATE: 5/11/15 | | APPLICABLE CODES: FBC 2010; WPB AMENDMENTS TO FBC 2010 | | CHAPTER 1; NEC 2008 | | REVIEW CYCLE: 1 | | ACTION: FAILED | | | | 1. PER FBC 907.2.1, GROUP A BLDGS W/AN OCCUPANT LOAD OF | | 300 OR GREATER ARE REQUIRED TO HAVE A FIRE ALARM SYSTEM | | INSTALLED (SEE FIRE REVIEW) | | 2. THE FIRE ALARM SYSTEM SHALL BE ON A SEPARATE PERMIT | | AND SUBMITTAL ACCOMPANIED BY THE PROPER FIRE ALARM | | DRAWINGS. | | 3, MISSING EXIT LIGHT IN STORAGE ROOM, LOCKER ROOM AND | | IN THE AREA MID-WAY AS YOU EXIT THE REAR AREA INTO THE | | LOUNGE. | | 4. OUTLETS BEHIND THE BAR, IF WITHIN 6' OF THE SINK | | SHALL BE GFI PROTECTED. | | 5. AS PER NEC 210.62, YOU ARE REQUIRED TO HAVE AN | | OUTLET AT THE TOP OF EVERY SHOW WINDOW FOR EVERY 12' OR | | FRACTION THEREOF. THIS OUTLET SHALL BE WITHIN 18" OF | | THE TOP OF THE WINDOW. | | 6.AS PER NEC 600.5, YOU ARE TO HAVE A DEDICATED SIGN | | OUTLET LOCATED ACCESSIBLE ABOVE EVERY ENTRANCE. | | 7. AS PER NEC 700.12(F) EMERGENCY LIGHTING SHALL BE ON | | THE SAME LIGHTING CIRCUIT AS THE AREA THEY OCCUPY. | | INDICATE LIGHTING CIRCUIT NUMBER TO ASCERTAIN | | COMPLIANCE. | | 8. AS PER FBC 2010 ENERGY 502.3.8, ALL RECESSED | | LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | CONDITIONED & UNCONDITIONED SPACE. | | 9. AS PER FBC 2010 ENERGY, ALL LIGHTING SHALL COMPLY | | WITH SECTION 505. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-07-07 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2015-07-07 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2015-07-07 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-05-11 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2015-05-11 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2015-05-11 |
Time |
13:38 |
Sent To |
|
|
Notes |
2015-05-11 14:36:29 | PERMIT # 15050177 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | PLAN APPROVED WITH COMMENTS. ALL COMMENTS MUST BE | | ADDRESSED AND/OR COMPLIED WITH. | | | | PROVISO: | | 1) SHEETS "C-1" AND "OC-1" SHOW DIFFERENT OCCUPANT | | LOADS. SHEET "C-1" STATES 341 OCCUPANTS AND SHEET | | "OC-1" SHOWS A TOTAL OF 150 OCCUPANTS. PLEASE PROVIDE | | THE CORRECT OCCUPANT LOAD. | | | | 2) PER NFPA 101, CHAPTER 13: EXISTING ASSEMBLY | | OCCUPANCIES - ASSEMBLY OCCUPANCIES WITH OCCUPANT LOADS | | OF 300 OR MORE SHALL BE PROVIDED WITH AN APPROVED FIRE | | ALARM SYSTEM AND PROTECTED BY AN APPROVED, SUPERVISED | | AUTOMATIC SPRINKLER SYSTEM. | | | | 3) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | 4) EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | 5) PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS | | WITH EXIT SIGNS. | | | | 6) DJ BOOTH, PLATFORM, & STAGE: HANDRAILS ARE REQUIRED | | ON BOTH SIDES OF THE STAIR. HANDRAILS SHALL BE LOCATED | | NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES | | ABOVE THE SURFACE OF THE TREAD, MEASURED VERTICALLY TO | | THE TOP OF THE RAIL FROM THE LEADING EDGE OF THE TREAD. | | HANDRAIL ENDS SHALL BE RETURNED TO THE WALL OR FLOOR OR | | SHALL TERMINATE AT NEWEL POSTS. HANDRAIL CROSS SECTION | | SHALL HAVE A DIAMETER OF NOT LESS THAN 1.25 INCHES AND | | NOT MORE THAN 2 INCHES. | | | | 7) FOR ASSEMBLY AND EDUCATIONAL OCCUPANCIES WITH AN | | OCCUPANT LOAD OF 100 OR MORE PERSONS (50 PERSONS PER | | THE FLORIDA BUILDING CODE), PANIC HARDWARE SHALL BE | | PROVIDED ON DOORS TO RELEASE THE LOCK/LATCH. NO OTHER | | LOCKS OR LATCHES ARE PERMITTED THAT WOULD NOT BE | | RELEASED BY THE PANIC HARDWARE. AS A SUBSTITUTE FOR | | PANIC HARDWARE, THE MAIN ENTRANCE IS PERMITTED TO HAVE | | AN INTERIOR KEYED DOOR LOCK (AND NO LATCH) WITH A | | READILY VISIBLE SIGN STATING THIS DOOR TO REMAIN | | UNLOCKED WHEN THE BUILDING IS OCCUPIED. SIGN LETTERS | | SHALL BE AT LEAST 1 INCH IN HEIGHT. A THUMB TURN STYLE | | LOCK IS NOT PERMITTED TO BE SUBSTITUTED FOR A KEYED | | LOCK. | | | | | | SUE ELLEN CALDERON, MPA | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 644-7326 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-08-11 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-07-22 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-30 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-06-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-06-03 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-05-06 |
Time |
13:34 |
Sent To |
|
|
Notes |
2015-06-05 10:45:27 | LAST REVIEW DONE ON 6/3/15. | 2015-05-07 13:33:31 | B08 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2015-09-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-09-08 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-09-08 |
Time |
17:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2015-08-18 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-08-18 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-08-18 |
Time |
13:32 |
Sent To |
|
|
Notes |
2015-08-18 14:12:15 | 3RD REVIEW: FBC 2010 MECHANICAL | | PERMIT #15050177 | | 8/18/15 | | | | 1) THE REVISED ENERGY CALCULATIONS MUST BE SIGNED AND | | DATED BY THE PERSON WHO PREPARED THEM- | | SECTION103.2.3.1.2 FBC-10- ENERGY CONSERVATION. | | 2) SHEET M-1: AS PREVIOUSLY REQUESTED PROVIDE THE | | VENTILATION CALCULATION AND OUTSIDE AIR CFM'S FOR THE | | VIP AREA. CORRECT THE TOTAL CFM'S OF O/A FOR THE OFFICE | | TO 33 CFM'S. | | 3) AS PREVIOUSLY REQUESTED PROVIDE THE NOA OR FLORIDA | | PRODUCT APPROVAL FOR THE O/A LOUVER. | | 4) PROVIDE MANUFACTURER'S SPECIFICATIONS AND | | INSTALLATION INSTREUCTIONS FOR THE AREA SMOKE | | DETECTORS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2015-07-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-07-10 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-07-10 |
Time |
11:07 |
Sent To |
|
|
Notes |
2015-07-10 11:10:02 | 2ND REVIEW: FBC 2010 MECHANICAL | | PERMIT #1505177 7/10/15 | | | | 1) THE ENERGY EFFICIENCY FORM IS LISTING TWO 13 SEER | | SYSTEMS, AND ONE 10 SEER SYSTEM WHICH IS NOTED ON THE | | FORM AS A FAILED COMPLIANCE, HOWEVER THE PLAN IS | | INDICATING THREE 16 SEER SYSTEMS: PLEASE CORRECT. | | 2) SHEET M-1: THE 24X24 INCH RETURN GRILL IS UNDERSIZED | | FOR 1600 CFM PER SECTION 601.4 (50 SQ. INCHES PER 100 | | CFM REQUIRED- MINIMUM GRILL SIZE IS APPROXIMATELY 28 X | | 28 SQ. INCHES). PLEASE NOTE THAT THE PLANS DO NOT SHOW | | WHAT THE GRILL IS TO BE MOUNTED TO- A DOOR AT THE FRONT | | OF THE CLOSET IS NOT SHOWN ON THE PLANS. | | 3) M-1: INDICATE HOW ACCESS FOR SERVICE IS BEING | | PROVIDED TO AHU-1 & 3 EACH LOCATED ABOVE THE DROP | | CEILINGS, AND SHOW THE LEVEL 30 X 30 INCH LEVEL WORKING | | SPACE IN FRONT OF THE CONTROL SIDES OF THE UNITS- | | REFERENCE SECTION 306.1. | | 4) M-1: THE ASHRAE 62- 89 VENTILATION CALCULATIONS | | SHOWN ON THE PLAN ARE OUTDATED. REVISE THE CALCULATIONS | | AS PREVIOUSLY REQUESTED USING TABLE 403.3. A) | | BAR/LOUNGE- 7.5 CFM PER PERSON PLUS .18 CFM PER SF. B) | | STORAGE- .12 CFM PER SF. C) OFFICE- 5 CFM PER | | PERSON/.06 CFM PER SF. D) STAGES- 10 CFM PER PERSON/.06 | | CFM PER SF. E)THE LOCKER/SHOWER ROOM REQUIRES EXHAUST | | RATES OF 50 CFM INTERMITTENT OR 20 CFM CONTINUOUS FOR | | THE SHOWER, AND .25 CFM PER SF FOR THE ROOM ITSELF. F) | | AN ACCURATE CALCULATION FOR THE VIP ROOM WILL DEPEND ON | | THE TYPE OF ACTIVITY CONDUCTED IN THE SPACE. | | 5) M-1: THERE ARE SD SYMBOLS SHOWN AT THE RETURNS OF | | THE THREE AIR HANDLERS. PLEASE CLARIFY IF THESE ARE | | MEANT TO BE DUCT SMOKE DETECTOR SYMBOLS (DS), AND | | CLARIFY HOW THEY WILL BE SUPERVISED PER SECTION | | 606.4.1. PLEASE NOTE THAT DETECTORS SHALL BE INSTALLED | | IN SUPPLY SYSTEMS WITH A DESIGN CAPACITY GREATER THAN | | 2000 CFM- 606.2.1 | | 6) M-1: AS PREVIOUSLY REQUESTED PROVIDE DUCT HANGING | | AND CONNECTION DETAILS, INCLUDING THE DISTRIBUTION | | BOXES- CHAPTER 5- SMACNA 2005. | | 7) M-1: SOME DUCT SIZES ARE STILL NOT SHOWN IN THE REAR | | CORRIDOR AND VIP ROOM: PLEASE LIST THESE SIZES AND THE | | DB SIZES. | | 8) M-1: A DUCT CONNECTION BETWEEN THE R/A GRILL IN THE | | CORRIDOR AND A SUPPLY DIFFUSER IN THE OFFICE IS SHOWN | | ON THE PLAN: PLEASE CORRECT. | | 9) M-1: PLEASE ENLARGE THE DRYWELL DETAIL FOR CLARITY. | | 10) AS PREVIOUSLY REQUESTED, PROVIDE TWO COPIES OF FL. | | PRODUCT APPROVALS OR MIAMI-DADE NOA'S FOR THE O/A | | INTAKE LOUVERS, AND FOR THE AST AC STAND REVIEWED AND | | APPROVED BY THE DESIGN PROFESSIONAL OF RECORD- DCA RULE | | 9N-03. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2015-06-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2015-06-03 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2015-06-03 |
Time |
16:58 |
Sent To |
|
|
Notes |
2015-06-03 17:49:31 | 1ST REVIEW: FBC 2010 MECHANICAL | | | | 1) PROVIDE AC LOAD CALCULATIONS IN ACCORDANCE WITH | | ASHRAE/ACCA STANDARD 183, OR ACCA MANUAL N FOR THE NEW | | SYSTEMS- SECTION 503.2.1 FBC-10 ENERGY CONSERVATION. | | 2) PROVIDE VENTILATION CALCULATIONS FOR THE A2 | | OCCUPANCY INCLUDING A TABLE DEPICTING THE REQUIRED AND | | PROVIDED O/A OR EXHAUST FOR EACH ROOM OR SPACE ON THE | | PLAN- TABLE 403.3 FBC-10 MECHANICAL. | | 3) SHEET M-1: PLEASE INDICATE ALL THE DUCT SIZES ON THE | | PLAN: MANY ARE NOT INDICATED. | | 4) PLEASE LABEL THE AIR HANDLERS AS EITHER 1, 2, OR 3. | | 5) M-1: SHOW THE OUTSIDE AIR INTAKE DUCTS FOR THE AHU'S | | SHOWN BY THE CONCESSION STAND, AND OVER THE MEN'S | | TOILET ROOM. INDICATE THE TYPE AND SIZE OF THE DUCTS, | | AIR INLET LOCATION, AND TYPE AND SIZE OF INLET GRILL OR | | LOUVER. PLEASE NOTE, TWO COPIES OF A FL. PRODUCT | | APPROVAL OR MIAMI-DADE NOA WILL BE REQUIRED. | | 6) M-1: PROVIDE MOTORIZED DAMPERS FOR THE OUTSIDE AIR | | INTAKES THAT WILL AUTOMATICALLY SHUT OFF WHEN THE | | SYSTEMS OR SPACES ARE NOT IN USE- SECTION 503.2.4.4 | | FBC-10 ENERGY CONSERVATION. | | 7) M-1: PROVIDE EXHAUST VENTILATION PLANS AND | | SPECIFICATIONS FOR THE TOILET ROOMS, INCLUDING EXHAUST | | FAN EQUIPMENT SCHEDULES, THE TYPE AND SIZE OF EXHAUST | | DUCTS, DUCT RUNS, AND TERMINATION LOCATIONS. | | 8) M-1: INDICATE SUPPLY CFM'S AT THE 24 X 24 DIFFUSERS | | SHOWN ON THE PLAN AND THE LEGEND. | | 9) M-1: PER DETAIL NO. 2 ON M-2, SHOW THE LOCATIONS OF | | ALL REQUIRED DUCT SMOKE DETECTORS, AND TEST STATIONS ON | | THE PLAN- SEE FIRE DEPARTMENT COMMENTS REGARDING THE | | REQUIRED FIRE ALARM SYSTEM. | | 10) M-1: PROVIDE AN AIR DISTRIBUTION SCHEDULE ON THE | | PLAN INDICATING THE MAKES AND MODELS OF DIFFUSERS AND | | GRILLS. SHOW DUCT HANGING AND CONNECTION DETAILS. | | 11) PROVIDE CONDENSATE DISPOSAL PLANS FOR THE NEW AIR | | HANDLERS: SHOW THE TYPE AND SIZE OF PIPING, PIPING | | RUNS, AND DISCHARGE LOCATIONS- SECTION 307 FBC-10 | | MECHANICAL. | | 12) SITE SPECIFIC, WINDLOAD TIE-DOWN ENGINEERING IS | | REQUIRED FOR THE NEW CONDENSER STANDS ON THE ROOF- | | SECTION 301.12 FBC-10 MECHANICAL. PROVIDE DESIGN | | CRITERIA AND DESIGN PRESSURES ON THE PLANS. | | | | CHRISTOPHER COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2015-08-20 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2015-08-20 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2015-08-20 |
Time |
15:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2015-07-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-07-21 |
Time |
06:05 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-07-21 |
Time |
04:52 |
Sent To |
|
|
Notes |
2015-07-21 06:00:13 | 1) SUBMIT A NARRATIVE THAT CLEARLY REFLECTS THE SCOPE | | OF UNPERMITTED WORK THAT WAS DONE AND THE SCOPE OF WORK | | TO CORRECT THE VIOLATION.WPB AMEND. TO FBC SEC. 107.1, | | 107.2.1. 2ND REQUEST. | | 2) CLEARLY SHOW ON THE PLANS THE ENTIRE SCOPE OF | | PLUMBING WORK TO BE DONE.WPB AMEND. TO FBC SEC.107.2.1. | | 3) PAGE 1 - CLEARLY SHOW THE WIDTH OF THE TOILET ROOMS. | | THE LAVATORY SHALL NOT ENCROACH INTO THE CLEAR FLOOR | | SPACE FOR THE WATER CLOSET.FAC 604.3.1. | | 4) SHOW THE FIXTURE CLEARANCE OF THE HANDICAP WATER | | CLOSET FROM THE NEAREST ADJACENT FINISHED WALL TO THE | | CENTERLINE OF THE WATER CLOSET.COMPLY WITH FGURE 604.2 | | IN THE FAC. | | 5) SHOW THE LOCATION OF THE CONTROL WALL FOR THE | | HANDICAP SHOWERS ON SHT.#1. | | 6) THE SHOWER IN THE LOCKER ROOM DOES NOT APPEAR TO | | SUPPLY THE 36" | | X 48" CLEAR FLOOR SPACE ADJACENT TO THE SHOWER. FAC | | SEC.608.2.1. | | 7) THE RESTROOMS ARE NOT SHOWN ON THE SANITARY OR WATER | | RISERS. WPB AMEND. TO FBC SEC. 107.3.5.1.3. | | 8) LABEL THE FIXTURES ON THE WATER RISER. WPB AMEND. TO | | FBC SEC. 107.2.1. | | 9) THE SANITARY RISER AND THE WATER RISER DOES NOT | | CORRELATE WITH THE FLOOR PLAN. WPB AMEND. TO FBC SEC. | | 107.5.1.3. | | 10) THE ENTIRE HOT AND COLD WATER LINES ARE PIPED IN | | 1/2 " PIPE. SUBMIT CALCULATIONS THAT THIS SIZING WILL | | SUPPLY THE MINIMUM FLOW RATES AND PRESSURES REQUIRED AT | | EACH FIXTURE PER TABLE 604.3 OF 2010 FPC. | | 11) THE PLANS NOTE AN OCCUPANCY OF A-2 AND A OCCUPANT | | LOAD OF 267 PERSONS. TABLE 403.1 OF THE 2010 FL. PLBG. | | CODE WOULD REQUIRE 4 WATER CLOSETS FOR THE MALES AND 4 | | WATER CLOSETS FOR THE FEMALES. | | 12) INDICATE THE PREVIOUS OCCUPANCY OF THIS SPACE PER | | CHAPTER 302 OF THE 2010 FBC. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-06-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-06-03 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-06-03 |
Time |
14:12 |
Sent To |
|
|
Notes |
2015-06-03 14:28:30 | 1) THE PLANS ARE UNCLEAR AS TO THE LEVEL AND SCOPE OF | | INTERIOR ALTERATIONS BEING DONE. SUBMIT A NARRATIVE | | THAT CLEARLY REFLECTS THE SCOPE OF UNPERMITTED WORK | | THAT WAS DONE AND THE SCOPE OF WORK TO CORRECT THE | | ISSUE. WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 2) CLEARLY SHOW ON THE PLANS THE SCOPE OF WORK TO BE | | DONE. WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 3) THE DESIGN PROFESSIONAL SHALL INDICATE ON THE PLANS | | THE LEVEL OF ALTERATION OF THE WORK PER THE FL. | | EXISTING BUILDING CODE SEC.401.4. | | 4) CLEARLY INDICATE THE WORK AREA ON THE PLANS PER THE | | FL. EXISTING BUILDING CODE SEC. 401.2. | | 5) PAGE 1 - CLEARLY INDICATE THE WIDTH OF THE TOILET | | ROOMS. WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | 6) SHT. OC-1 - HOW CAN THE BAR AREA BE DESIGNATED AS A | | BUSINESS OCCUPANCY? THIS AREA IS AN A-2 AND SHALL BE | | INCLUDED IN THE A-2 OCCUPANT LOAD COUNT. 201 FBC 303. | | 7) A BUILDING, FACILITY OR ELEMENT THAT IS ALTERED | | SHALL COMPLY WITH THE PROVISIONS OF THE FBC- | | ACCESSIBILITY. REFER TO FL. ACCESSIBILITY CODE SEC. 202 | | FOR ALTERATIONS TO AN EXISTING BUILDING. | | 8) SUBMIT PLUMBING PLANS FOR ANY CHANGES TO THE | | SANITARY OR WATER SYSTEM.WPB AMEND. TO 2010 FBC SEC. | | 107.2.1. | | 9) SHT. LS-1 - PLEASE PROVIDE DIMENSIONS FOR ALL | | RESTROOMS AND SHOWER STALLS TO REVIEW FOR REQUIRED | | COMPLIANCE WITH THE FAC. PROVIDE ENLARGED FLOOR PLANS & | | ELEVATIONS OF BATHROOMS & SHOWERS. SHOW FLOOR | | CLEARANCES FOR PLUMBING FIXTURES, PLUMBING FIXTURE | | CLEARANCES, GRAB BARS HEIGHTS, ETC. | | | | NOTE: DUE TO LACK OF INFORMATION ON THE PLANS AS TO THE | | EXTENT OF THE ALTERATIONS, THIS IS NOT A COMPREHENSIVE | | REVIEW. MORE COMMENTS MAY BE GENERATED ONCE A COMPLETE | | SET OF PLANS IS SUBMITTED. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
|