Plan Review Stops For Permit 15040881 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-06-30 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-06-30 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-06-30 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-06-16 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-06-16 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-06-16 |
Time |
16:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-05-13 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-05-13 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-05-13 |
Time |
17:08 |
Sent To |
|
|
Notes |
2015-05-13 17:07:59 | ****CORRECTIONS**** | | | | ART LANGE ? BUILDING INSPECTOR | | 561-805-6667 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | BEDROOMS, FBC R310. | | | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | FAC9B72, WWW.FLORIDABUILDING.ORG. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-06-27 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-06-27 |
Time |
18:00 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-27 |
Time |
18:00 |
Sent To |
B |
|
Notes |
2015-06-27 18:04:00 | ROUTED TO A. C. LANGE FOR BUILDING REVIEW OF THE NEW | | PLAN PROVIDED. | | | 2015-06-27 18:01:55 | PROVIDE A COMPLETE PANEL SCHEDULE FOR THE INSPECTOR IN | | THE FIELD NEC 408.4 | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-06-11 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-06-11 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-11 |
Time |
08:40 |
Sent To |
B |
|
Notes |
2015-06-11 08:55:57 | 6/11/2015 | | PROJECT: RESIDENTIAL REMMODEL | | PERMIT#: 15040881 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 2ND ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | COMMENTS: | | | | 1) INDICATE THE LOCATION OF THE ELECTRICAL PANEL ON THE | | FLOOR PLAN. 107.3.5.1.2. | | THE ELECTRICAL PANEL HAS NOW BEEN INDICATED ON THE PLAN | | BUT IT APPEARS TO BE LOCATED IN THE BATHROOM. THE | | ELECTRICAL PANEL IS NOT APPROVED FOR USE IN THE | | BATHROOM. NEC 240.24(E) | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-04-29 |
|
|
Cont ID |
|
Sent By |
misc2 |
Date |
2015-04-29 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-04-29 |
Time |
13:46 |
Sent To |
B |
|
Notes |
2015-04-29 13:51:18 | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | COMMENTS: | | | | 1) INDICATE THE LOCATION OF THE ELECTRICAL PANEL ON THE | | FLOOR PLAN. 107.3.5.1.2 | | | | 2) INDICATE THE LOCATION FOR THE SMOKE DETECTORS. | | FBC-RESIDENTIAL 314 AND 315. | | WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | 314 AND 315. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-07-02 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2015-06-30 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2015-06-25 |
Time |
17:39 |
Sent To |
|
|
Notes |
2015-06-25 17:39:33 | SENT TO D HAYES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-06-16 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-06-16 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-06-09 |
Time |
14:57 |
Sent To |
|
|
Notes |
2015-06-09 14:57:51 | SENT TO D HAYES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-05-13 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-05-13 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-04-23 |
Time |
16:41 |
Sent To |
|
|
Notes |
2015-04-23 16:42:01 | ***EXPEDITED**** | | TO ELEC BOX | | |
|
|