Plan Review Stops For Permit 15040853 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-07-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-07 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-07 |
Time |
17:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-05-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-05-04 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-05-04 |
Time |
10:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-07-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-07 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-07 |
Time |
17:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-05-12 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-05-12 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-05-12 |
Time |
13:49 |
Sent To |
|
|
Notes |
2015-05-12 13:50:58 | SCOPE OF ELECTRICAL WORK NOT PROVIDED. SEE NOTE #9 ON | | PLANS. RL |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
N |
Date |
2015-07-16 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-07-16 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-07-15 |
Time |
08:56 |
Sent To |
|
|
Notes |
2015-07-16 08:00:42 | 1. WORK WITHIN RIGHT OF WAY TO BE AUTHORIZED UNDER | | DRIVEWAY PERMIT. | | | | 2. PARKING AREA STRIPING TO BE AUTHORIZED UNDER PAVING | | PERMIT. | | | | KELLY CRANFORD, P.E. | | LAND DEVELOPMENT ENGINEER | | PUBLIC WORKS DEPARTMENT | | CITY OF WEST PALM BEACH | | [email protected] | | 561-494-1098 (OFFICE) |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2015-05-07 |
|
|
Cont ID |
|
Sent By |
cranford |
Date |
2015-05-07 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
cranford |
Date |
2015-05-07 |
Time |
11:47 |
Sent To |
Z |
|
Notes |
2015-05-07 12:33:08 | PUBLIC WORKS DEPT. | | LAND DEVELOPMENT | | | | 1. APPLICANTS FOR DEMOLITION AND/OR BUILDING PERMITS TO | | PERFORM LAND DISTURBING CONSTRUCTION AND LAND | | DEVELOPMENT ACTIVITIES SHALL SUBMIT A BOND OR DEPOSIT | | IN AN AMOUNT COVERING THE COST ASSOCIATED WITH | | IMPLEMENTATION OF THE SWPPP LAND STABILIZATION OF THE | | SITE. PLEASE SUBMIT A COPY OF THE AUTOCALC CERTIFIED | | COST ESTIMATE FORM AND A BOND FOR THE LAND | | STABILIZATION OF THE SITE. | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ THE | | BOND WILL BE RELEASED UPON APPROVED INSPECTION OF | | TIE-BEAMS OR SIMILAR VERTICAL CONSTRUCTION. (CITY CODE | | SECTION 94-450) | | | | 2. A STORMWATER POLLUTION PREVENTION PLAN (SWPPP) MUST | | BE SUBMITTED. THE PLAN WILL NEED TO ADDRESS PREVENTING | | TURBID WATER, DIRT, DUST AND OTHER CONSTRUCTION DEBRIS | | FROM LEAVING THE SITE EXCEPT IN SEALED CONTAINERS. | | (SECTION 94-450 OF THE CODE OF ORDINANCES) | | | | KELLY CRANFORD, P.E. | | LAND DEVELOPMENT ENGINEER | | PUBLIC WORKS DEPARTMENT | | CITY OF WEST PALM BEACH | | [email protected] | | 561-494-1098 (OFFICE) | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-07-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-07 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-07 |
Time |
17:11 |
Sent To |
ENG |
|
Notes |
2015-07-07 17:12:14 | STAMPED FOR PL TO EXPEDITE. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-04-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-04-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-04-27 |
Time |
12:48 |
Sent To |
|
|
Notes |
2015-04-27 13:00:33 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THE FIRE INSPECTOR WILL CONFIRM THE LOCATION OF SMOKE | | DETECTORS AND FIRE EXTINGUISHERS AT FINAL FIRE | | INSPECTION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-21 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-06 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-05-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-05-27 |
Time |
06:59 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-23 |
Time |
14:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-07-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-07 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-07-07 |
Time |
17:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-05-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-05-27 |
Time |
06:55 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-05-27 |
Time |
05:18 |
Sent To |
|
|
Notes |
2015-05-27 06:53:26 | 1) SHT.A0.2 - DEMOLITION NOTE #10 REFERS TO THE REMOVAL | | OF AN EXISTING GAS LINE TO BE CUT AND CAPPED BELOW THE | | EXISTING FLOOR LINE. THIS IS VAGUE AND MORE INFORMATION | | IS REQUIRED. INDICATE ON THE PLAN EXACTLY WHERE THIS | | EXISTING LINE WILL BE REMOVED AND "CAPPED"; PIPING | | CANNOT BE CAPPED OR RUN UNDER A BUILDING SLAB EXCEPT | | WHERE THE INSTALLATION COMPLIES WITH FGC SEC.404.12. | | CLARIFY. SECTION 406.7 OF THE 2010 FUEL GAS CODE | | REQUIRES THAT THE GAS SUPPLY SHALL BE SHUT OFF AND THE | | LINE PRESSURE VENTED TO THE OUTDOORS. THE REMAINING GAS | | IN THE SECTION OF PIPE IS TO BE PURGED WITH AN INERT | | GAS AS REQUIRED BY TABLE 406.7.1.SUBMIT ADDITIONAL | | INFORMATION AND DETAILS AS TO EXACTLY WHAT IS GOING TO | | BE CAPPED, WHERE, HOW, ETC. AIR CANNOT BE USED TO PURGE | | PIPING BECAUSE IT CONTAINS OXYGEN. WPB AMEND. TO FBC | | SEC. 107.2.1. | | 2) SHOW THE DIMENSIONS OF THE NEWLY CREATED SHOWER ON | | SHT. A1.0. THE ROLL -IN SHOWER DIMENSIONS SHALL COMPLY | | WITH FAC SEC.608.2.2. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-07-20 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-07-20 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-07-20 |
Time |
15:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2015-05-08 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2015-05-08 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-05-08 |
Time |
12:17 |
Sent To |
|
|
Notes |
2015-05-08 12:19:08 | 5/8/15 ZONING FAILED | | | | 1. SUBMIT PARKING LOT LAYOUT SHOWING THE DIMENSION OF | | EACH PARKING SPACE |
|
|