Plan Review Details - Permit 15040624
Plan Review Stops For Permit 15040624 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-05-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-05-06 |
Time |
06:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-05-06 |
Time |
06:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-06-19 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-06-19 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-06-19 |
Time |
12:47 |
Sent To |
|
|
Notes |
2015-06-19 13:43:42 | APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN APPROVED | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | FEE(S). | | | | 1) POWER FOR OFFICE FURNISHINGS CONSISTING OF LIGHTING | | ACCESSORIES ANDWWIRED PARTITIONS SHALL COMPLY WITH NEC | | 605 | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-05-18 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2015-05-18 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-05-18 |
Time |
16:51 |
Sent To |
|
|
Notes |
2015-05-18 17:03:24 | 5/18/2015 | | PROJECT: | | PERMIT#: | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | ELECTRICAL PLAN REVIEW | | ACTION: | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | COMMENTS: | | | | 1) PROVIDE EMERGENCY LIGHTING SO THAT THE FAILURE OF | | ANY INDIVIDUAL LIGHTING ELEMENT, SUCH AS THE BURNING | | OUT OF A LAMP, CANNOT LEAVE IN TOTAL DARKNESS ANY SPACE | | THAT REQUIRES EMERGENCY ILLUMINATION. NEC 700.16 | | | | SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | ARE REQUIRED FOR FIRE ALARM, ACCESS CONTROL SYSTEM, | | SECURITY, CCTV, AUDIO/VIDEO, NETWORK, DATA, AND, | | COMMUNICATION. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-05-04 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2015-05-04 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2015-05-04 |
Time |
16:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-06-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-19 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-10 |
Time |
15:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-06-10 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2015-06-10 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2015-04-21 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2015-06-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-06-19 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-06-19 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2015-05-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-05-06 |
Time |
07:04 |
Rev Time |
|
Received By |
jwitmer |
Date |
2015-05-06 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-05-28 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-05-28 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-05-27 |
Time |
04:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2015-06-23 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-06-23 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-22 |
Time |
16:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2015-06-09 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2015-06-09 |
Time |
15:52 |
Sent To |
|
|
Notes |
|
|
|