Plan Review Details - Permit 15040521
Plan Review Stops For Permit 15040521 |
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2015-04-20 |
|
|
Cont ID |
|
Sent By |
Mgonzale |
Date |
2015-04-20 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2015-04-20 |
Time |
|
Sent To |
P |
|
Notes |
2015-04-20 18:56:20 | PASSED WITH PROVISO: | | | | #1 THE INTERCEPTORS SHALL BE SIZED AND INSTALLED IN | | ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AMD | | REQUIREMENTS OF THE FLORIDA PLUMBING CODE. | | | | #2 ANY STRUCTURAL ELEMENT, SLAB, COVERING PLATE, ACCESS | | DOOR, TRAFFIC-RATED LIDS OR ANY OTHER ELEMENT TO BE | | INSTALLED AND IS NOT WITHIN THE MANUFACTURER'S | | INTRUCTIONS FOR THE INTERCEPTORS WILL BE REQUIRED THAT | | A LICENSED FLORIDA PROFESSIONAL ENGINEER DESIGN AND | | SIZE IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE, | | STATE REGULATION, AND CITY OF WPB CODES AND ORDINANCES. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-04-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-21 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-16 |
Time |
06:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-04-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-21 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-21 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-04-16 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-16 |
Time |
07:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-16 |
Time |
06:32 |
Sent To |
|
|
Notes |
2015-04-16 07:04:44 | 1) THE INTERCEPTOR DETAIL DOES NOT SHOW THE INLET AND | | OUTLET PIPING DETAILS PER THE 2010 FPC SEC.1003.5.3. | | 2) THE CONTRACTOR STATED TO ME THAT THE EXISTING TANKS | | ARE 2450 GALLONS BUT THESE TANKS ARE 3,000 GALLONS. | | CLARIFY. THE 2010 FL. PLUMBING CODE SEC.1003.5.1 STATES | | THE MAXIMUM VOLUME OF AN INDIVIDUAL GREASE INTERCEPTOR | | CHAMBER SHALL BE 1250 GALLONS.WHEN THE CAPACITY IS | | GREATER THAN 1250 GALLONS, THEY SHALL BE INSTALLED IN | | SERIES. SUBMIT DOCUMENTATION FROM THE HOSPITAL | | CONFIRMING THE CAPACITY OF THE EXISTING TANKS ( A | | RECENT PUMP-OUT BILL THAT SPECIFIES THE CAPACITY WILL | | SUFFICE). | | 3) TWO DIFFERENT TANK SPECIFICATIONS HAVE BEEN | | SUBMITTED AND THEY REFERENCE TWO DIFFERENT STATE | | APPROVAL NUMBERS.CLARIFY. SUBMIT A COPY OF THE STATE | | APPROVAL OF THE TANK THAT WILL BE INSTALLED.WPB | | AMENDMENTS TO 2010 FBC SEC. 107.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
|