Plan Review Details - Permit 15040430
Plan Review Stops For Permit 15040430
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-04-30 Cont ID  
Sent By jwitmer Date 2015-04-30 Time 06:15 Rev Time 0.00
Received By jwitmer Date 2015-04-30 Time 05:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-04-20 Cont ID  
Sent By jwitmer Date 2015-04-20 Time 14:43 Rev Time  
Received By jwitmer Date 2015-04-20 Time 12:01 Sent To  
Notes
2015-04-20 14:43:18BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15040430
 ADD: 5601 CORPORATE WAY # 320
 CONT: DRY ART CONSTRUCTION
 TEL: (561)436-3703
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE.
  
 1ST REVIEW
 DATE: MON. APRIL 20/2015
 ACTION: DENIED
  
 1) SHEET A1 SHOWS A VALUE OF $35,000.00 DOLLARS WORTH
 OF WORK BEING COMPLETED UNDER THIS PERMIT. THE 2010
 FBC-ACCESSIBILITY CODE 202.4 202.4 ALTERATIONS
 AFFECTING PRIMARY FUNCTION AREAS.
 IN ADDITION TO THE REQUIREMENTS OF 202.3, AN ALTERATION
 THAT AFFECTS OR COULD AFFECT THE USABILITY OF OR ACCESS
 TO AN AREA CONTAINING A PRIMARY FUNCTION SHALL BE MADE
 SO AS TO ENSURE THAT, TO THE MAXIMUM EXTENT FEASIBLE,
 THE PATH OF TRAVEL TO THE ALTERED AREA, INCLUDING THE
 REST ROOMS, TELEPHONES, AND DRINKING FOUNTAINS SERVING
 THE ALTERED AREA, ARE READILY ACCESSIBLE TO AND USABLE
 BY INDIVIDUALS WITH DISABILITIES, UNLESS SUCH
 ALTERATIONS ARE DISPROPORTIONATE TO THE OVERALL
 ALTERATIONS IN TERMS OF COST PURSUANT TO 202.4.1.
  
 THE DISPROPORTIONATE COST WILL BE $7,000.00. THE DESIGN
 PROFESSIONAL OR CONTRACTOR CAN LIST THE $7,000.00 WORTH
 OF UPGRADES IN MAKING THIS SUITE ACCESSIBLETHIS LIST
 WILL NEED TO SHOW ACCESSIBLE UPGRADES IN THIS ORDER .
 202.4.1 DISPROPORTIONATE COST.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
 TWO AREAS WHERE THE SUITE NEEDS TO MEET THE
 ACCESSIBILITY REQUIREMENTS ARE THE RESTROOM DOORS IN
 SERIES, SEE ACCESSIBILITY CODE 404.2.6 DOORS IN SERIES
 AND GATES IN SERIES. THE DISTANCE BETWEEN TWO HINGED OR
 PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE 48
 INCHES (1220 MM) MINIMUM PLUS THE WIDTH OF DOORS OR
 GATES SWINGING INTO THE SPACE.
  
 THE REPLACEMENT WATER FOUNTAIN WILL NEED TO COMPLY WITH
 ACCESSIBLE DRINKING FOUNTAINS 211.2 NO FEWER THAN TWO
 DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE
 DRINKING FOUNTAIN SHALL COMPLY WITH 602.7.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-05-04 Cont ID  
Sent By skennedy Date 2015-05-04 Time 14:55 Rev Time 0.00
Received By skennedy Date 2015-05-04 Time 14:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-04-27 Cont ID  
Sent By skennedy Date 2015-04-27 Time 15:59 Rev Time 0.00
Received By skennedy Date   Time   Sent To  
Notes
2015-04-27 16:03:171ST REVIEW: FBC 2010
  
 FBC- 107.3.5.3 ? PROVIDE COMPLETE LOAD CALCULATIONS,
 PANEL SCHEDULES AND SHOW CIRCUITS ON FLOOR PLAN. SHOW
 EMERGENCY LIGHTING CIRCUITS PER NEC 700.12 (F) (4)-
 EMERGENCY LIGHTING SHALL BE FED BY LIGHTING CIRCUIT OF
 SAME LOCAL AREA. *IF 3 OR MORE LIGHTING CIRCUITS SUPPLY
 THE AREA, EM LIGHTS MAY BE ON OWN CIRCUIT.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-04-27 Cont ID  
Sent By skennedy Date 2015-04-27 Time 15:44 Rev Time  
Received By skennedy Date   Time   Sent To  
Notes
2015-04-27 15:59:071ST REVIEW: FBC 2010
  
 FAILED TO ALLOW FOR RE-SUB W/O COMPLETE REVIEW W/
 CONTRACTORS APPROVAL.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-04-29 Cont ID  
Sent By pleduc Date 2015-04-29 Time   Rev Time 0.00
Received By pleduc Date 2015-04-29 Time 13:16 Sent To  
Notes
2015-04-29 13:24:492ND REVIEW COMMENTS.
  
 1ST REVEIW COMMENTS RESTATED:
  
 THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) SHEET A1 - THE NATURE OF THE REMODEL REQUIRES AN
 EVALUATION OF THE FIRE ALARM AND SPRINKLER SYSTEM FOR
 CODE COVERAGE AND COMPLIANCE.
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
 2) SHEET A1 - ADD EXIT LIGHTS WHERE HAND DRAWN
 INDICATED TO DIRECT ALONG THE EXIT PATH.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-04-15 Cont ID  
Sent By pleduc Date 2015-04-15 Time   Rev Time 0.00
Received By pleduc Date 2015-04-15 Time 09:53 Sent To  
Notes
2015-04-15 10:07:54THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) SHEET A1 - THE NATURE OF THE REMODEL REQUIRES AN
 EVALUATION OF THE FIRE ALARM AND SPRINKLER SYSTEM FOR
 CODE COVERAGE AND COMPLIANCE.
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
 2) SHEET A1 - ADD EXIT LIGHTS WHERE HAND DRAWN
 INDICATED TO DIRECT ALONG THE EXIT PATH.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-05-04 Cont ID  
Sent By skennedy Date 2015-05-04 Time 14:55 Rev Time 0.00
Received By skennedy Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-30 Cont ID  
Sent By jwitmer Date 2015-04-30 Time 06:15 Rev Time 0.00
Received By jwitmer Date 2015-04-27 Time 15:44 Sent To  
Notes
2015-04-27 15:45:14SENT TO B15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-27 Cont ID  
Sent By skennedy Date 2015-04-27 Time 15:44 Rev Time 0.00
Received By skennedy Date 2015-04-13 Time 17:08 Sent To  
Notes
2015-04-13 17:09:00B15

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2015-04-20 Cont ID  
Sent By jwitmer Date 2015-04-20 Time 14:43 Rev Time 0.00
Received By jwitmer Date 2015-04-20 Time 14:43 Sent To  
Notes
2015-04-20 14:43:51NOT REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-04-27 Cont ID  
Sent By skennedy Date 2015-04-27 Time 16:03 Rev Time 0.00
Received By skennedy Date 2015-04-27 Time 16:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-04-27 Cont ID  
Sent By skennedy Date 2015-04-27 Time 16:06 Rev Time 0.00
Received By skennedy Date 2015-04-27 Time 16:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-04-27 Cont ID  
Sent By skennedy Date 2015-04-27 Time 15:44 Rev Time  
Received By skennedy Date   Time   Sent To  
Notes
2015-04-27 16:06:021ST REVIEW: FBC 2010
  
 FAILED TO ALLOW FOR RE-SUB W/O COMPLETE REVIEW W/
 CONTRACTORS APPROVAL.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-04-17 Cont ID  
Sent By eschneid Date 2015-04-17 Time 16:01 Rev Time 0.25
Received By eschneid Date 2015-04-17 Time 11:58 Sent To  
Notes
2015-04-17 16:02:42INTERIOR RENO ONLY, DOES NOT EXCEED 50% OF THE
 STRUCTURE.