Plan Review Details - Permit 15040264
Plan Review Stops For Permit 15040264 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-04-22 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-22 |
Time |
07:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-04-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-04-21 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-21 |
Time |
09:29 |
Sent To |
|
|
Notes |
2015-04-21 09:36:49 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | | | FLAT ROOF NOA 11-0119.09 SUBMITTED: | | | | 1- SELECTED ASSEMBLY FROM PAGE 32 OF 41 CAN NOT BE | | USED. IT IT'S LIMITED BY GENERAL LIMITATION #9. SEE | | PAGE 33 OF 41. GENERAL LIMITATION #9 DOESN'T ALLOW | | RATIONAL ANALYSIS OR EXTRAPOLATION. (RAS 117 | | CALCULATIONS). SEE GENERAL LIMITATION #9 ON LAST PAGE | | OF NOA. NEED TO SELECT AN ASSEMBLY THAT IS LIMITED BY | | GENERAL LIMITATION #7, WHICH ALLOWS RATIONAL ANALYSIS | | OR EXTRAPOLATION TO MEET THE DESIGN PRESSURES OF SEC. | | R301.1 OF 2010 FBC-RESIDENTIAL. | | | | 2- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | SUBMITTED. SEC. R301.1 OF 2010 FBC-RESIDENTIAL. NOTE: | | PRESCRIPTIVE NAIL ENHANCING SUBMITTED IS NOT ALLOWED | | BECAUSE RAS 150 IS NOT ADOPTED BY THE CITY. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-04-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-04-16 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-16 |
Time |
08:58 |
Sent To |
|
|
Notes |
2015-04-16 09:34:55 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR THE FLAT ROOF TO BE INSTALLED. | | | | 2- CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY FROM THE | | SELECTED PRODUCT APPROVAL IS GOING TO BE USED TO VERIFY | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301 OF | | 2010 FBC-RESIDENTIAL. | | | | 3- IF THE FLAT ROOF SELECTED ASSEMBLY DOESN'T MEET THE | | DESIGN PRESSURES REQUIRED BY SEC. R301, THEN SIGNED AND | | SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2015-04-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-04-14 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-04-14 |
Time |
15:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-04-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-04-22 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-22 |
Time |
07:43 |
Sent To |
|
|
Notes |
2015-04-22 07:44:45 | RECEIVED E-MAIL FROM WILLIAM RIGGS. PRODUCT APPROVAL | | FL16709. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-04-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2015-04-21 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2015-04-21 |
Time |
11:09 |
Sent To |
|
|
Notes |
2015-04-21 11:13:39 | RECEIVED E-MAIL FROM WILL RIGGS. NOA 11-0119.09. |
|
|
|