Plan Review Details - Permit 15040099
Plan Review Stops For Permit 15040099 |
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2015-04-11 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2015-04-11 |
Time |
03:39 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-11 |
Time |
02:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-07 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-07 |
Time |
07:46 |
Sent To |
|
|
Notes |
2015-04-07 08:03:05 | ***NOTE*** - THIS REVIEW SUPERCEDES REVIEW # 1 AS THAT | | REVIEW STOP IS LOCKED AND THE REVIEW COULD NOT BE | | COMPLETED. T.LARGE. | | | | 1) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR ALL | | GAS APPLIANCES. APPLIANCES SHALL BE LISTED AND LABELED | | PER THE 2010 FBCR SEC. G2404.3. WPB AMEND. TO 2010 FBC | | SEC. 107.2.1. | | 2) SUBMIT A GAS RISER DIAGRAM FOR REVIEW. CLEARLY SHOW | | ALL CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS, THE | | PIPE SIZE, THE GAS PSI, THE TYPE OF PIPE MATERIAL, AND | | THE SIZE & CORRESPONDING EHD NUMBER OF CORRUGATED | | STAINLESS STEEL TUBING (CSST).2010 WPB AMEND. TO 2010 | | FBC SEC. 107.3.5.3. | | 3) INDICATE THE TYPE OF GAS .WPB AMEND. TO 2010 FBC | | SEC. 107.2.1. | | 4) SHOW THE BTU LOAD OF THE APPLIANCES ON THE GAS | | RISER.2010 WPB AMEND. TO 2010 FBC SEC. 107.3.5.3. | | 5) SHOW THE TOTAL DISTANCE FROM THE POINT OF DELIVERY | | (METER) TO THE MOST REMOTE GAS OUTLET. 2010 FBCR | | SEC.G2413.4. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-07 |
Time |
06:17 |
Sent To |
|
|
Notes |
2015-04-07 06:56:35 | 1) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR ALL | | GAS APPLIANCES. APPLIANCES SHALL BE LISTED AND LABELED | | PER THE 2010 FBCR SEC. G2404.3. WPB AMEND. TO 2010 FBC | | SEC. 107.2.1. | | 2) SUBMIT A GAS RISER DIAGRAM FOR REVIEW. CLEARLY SHOW | | ALL CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS, THE | | PIPE SIZE, THE TYPE OF PIPE MATERIAL,AND THE SIZE & | | CORRESPONDING EHD NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING (CSST). | | 3) INDICATE THE TYPE OF GAS . | | 4) SHOW THE BTU LOAD OF THE APPLIANCE ON THE GAS RISER. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-04-11 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2015-04-11 |
Time |
03:39 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-08 |
Time |
08:41 |
Sent To |
P |
|
Notes |
2015-04-10 08:42:09 | TO T. LARGE DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-07 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-03 |
Time |
12:07 |
Sent To |
|
|
Notes |
2015-04-03 12:07:54 | TO PLUMBING < $5K |
|
|
|