Plan Review Details - Permit 15040097
Plan Review Stops For Permit 15040097
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-04-07 Cont ID  
Sent By rlecky Date 2015-04-07 Time 11:29 Rev Time 0.00
Received By rlecky Date 2015-04-07 Time 11:19 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-12 Cont ID  
Sent By tklarge Date 2015-04-12 Time 03:41 Rev Time 0.00
Received By tklarge Date 2015-04-10 Time 08:56 Sent To  
Notes
2015-04-11 08:56:43SENT TO T LARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-07 Cont ID  
Sent By tklarge Date 2015-04-07 Time 12:34 Rev Time 0.00
Received By tklarge Date 2015-04-03 Time 08:15 Sent To  
Notes
2015-04-03 08:15:43TO ELEC
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2015-04-07 Cont ID  
Sent By rlecky Date 2015-04-07 Time 11:30 Rev Time 0.00
Received By rlecky Date 2015-04-07 Time 11:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-04-12 Cont ID  
Sent By tklarge Date 2015-04-12 Time 03:41 Rev Time 0.00
Received By tklarge Date 2015-04-12 Time 03:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-04-07 Cont ID  
Sent By tklarge Date 2015-04-07 Time 12:33 Rev Time 0.00
Received By tklarge Date 2015-04-07 Time 12:21 Sent To  
Notes
2015-04-07 12:32:531) SUBMIT MANUF. SPECIFICATIONS FOR THE PUMP/BASIN
 UNIT. WPB AMEND. TO FBC 107.2.1.
 2) THE SANITARY RISER DIAGRAM ON SHT. M2.1 SHOWS A 1
 1/2" DISCHARGE AND THE PLUMBING PLAN SHOWS A 2"
 DISCHARGE. CLARIFY.
 3) A FULL OPEN VALVE SHALL BE LOCATED ON THE DISCHARGE
 SIDE OF THE CHECK VALVE PER SEC. 712.2 OF 2010 FPC.
 4) THE CONNECTION OF THE EJECTOR TO THE BUILDING
 DRAIN/BUILDING SEWER PER 2010 FPC SEC.712.3.5 AND SHALL
 CONNECT A MINIMUM OF 10 FEET FROM THE BASE OF ANY SOIL
 OR WASTE STACK.
 5) THE PUMP SHALL HAVE THE MINIMUM CAPACITY AS
 SPECIFIED IN 2010 FPC SEC.712.4.2 AND TABLE 712.4.2.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved