Plan Review Details - Permit 15040095
Plan Review Stops For Permit 15040095
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-04-24 Cont ID  
Sent By jwitmer Date 2015-04-24 Time 07:21 Rev Time  
Received By jwitmer Date 2015-04-24 Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-05-05 Cont ID  
Sent By rlecky Date 2015-05-05 Time 14:28 Rev Time 0.00
Received By rlecky Date 2015-05-05 Time 14:21 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2015-04-08 Cont ID  
Sent By cranford Date 2015-04-08 Time 11:13 Rev Time 0.00
Received By cranford Date 2015-04-08 Time 11:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-04-09 Cont ID  
Sent By pleduc Date 2015-04-09 Time   Rev Time 0.00
Received By pleduc Date 2015-04-09 Time 13:56 Sent To  
Notes
2015-04-09 14:43:19THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF
 THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
 FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 13, 2010 EDITION.
 FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 72, 2010 EDITION.
 CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 241, 2009 EDITION.
 FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 10, 2010 EDITION.
 ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION.
  
 2) THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF
 THE FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE
 AND COMPLIANCE.
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By shill Date 2015-04-02 Time 12:32 Sent To  
Notes
2015-04-03 12:32:44B18
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2015-05-29 Cont ID  
Sent By ccole Date 2015-05-29 Time 15:34 Rev Time 0.00
Received By ccole Date 2015-05-29 Time 15:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-05-29 Cont ID  
Sent By ccole Date 2015-05-29 Time 15:26 Rev Time 0.00
Received By ccole Date 2015-05-29 Time 15:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-05-13 Cont ID  
Sent By tklarge Date 2015-05-13 Time 12:17 Rev Time 0.00
Received By tklarge Date 2015-05-13 Time 10:50 Sent To  
Notes
***NONE***