Plan Review Details - Permit 15040056
Plan Review Stops For Permit 15040056 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2015-04-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-04-23 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-04-23 |
Time |
17:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-05-26 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-05-27 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-05-26 |
Time |
12:53 |
Sent To |
FIRE |
|
Notes |
2015-05-26 13:14:41 | ALL PREVIOUS COMMENTS HAVE BEEN ADDRESSED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-05-07 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-05-07 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-05-07 |
Time |
14:30 |
Sent To |
I |
|
Notes |
2015-05-07 16:08:08 | THE FOLLOWING ITEMS NEED ATTEN/CORRECTION FOR A | | SUCCESSFUL REVIEW: | | PG. E1.1 | | 1. EVEN IF AS EXISTING, THE LIFE SAFETY ILLUMINATION | | SHALL BE SHOWN ON THE PLANS TO VERIFY COMPLIANCE | | 2, OFFICE RM 409 IS MISSING AN EXIT SIGN ABOVE THE DOOR | | AS WELL AS EMERGENCY LIGHTING INSIDE THE ROOM. AS PER | | NEC700.16, THERE CANT BE A ROOM LEFT IN TOTAL DARKNESS | | IN THE EVEN OF A POWER FAILURE. | | PG. E1.2 | | 1. ACCORDING TO THE NOTES, THE AREA ABOVE THE CEILING | | IS ALL A PLENUM, MAKE CERTAIN THAT THE NEW TRANSFORMER | | INDICATED ABOVE THE CEILING IT THE IT ROOM IS LISTED | | FOR A PLENUM. | | PG. E2.1 | | 1. VENDING MACHINES AND/OR THEIR CIRCUIT SHALL COMPLY | | WITH NEC422..51 | | 2. NEW PANEL "LC" AS WELL AS ALL EXISTING, SHALL BEAR | | THE REQUIRED FLASH PROTECTION DECAL AS INDICATED IN | | NEC110.16 | | 3. THE RISER DIAGRAM IS NOT COMPLETE. THE RISER DIAGRAM | | SHALL INCLUDE IN ADDITION TO ALL THE EXISTING LOADS, | | THE STANDBY GENERATOR AS WELL. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2015-05-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-05-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-05-27 |
Time |
17:09 |
Sent To |
PC |
|
Notes |
2015-05-27 17:12:40 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF | | THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE | | INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND | | ALL OTHER APPLICABLE CODES OR STANDARDS. | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 13, 2010 EDITION. | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 72, 2010 EDITION. | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 241, 2009 EDITION. | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 10, 2010 EDITION. | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | 2) THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF | | THE FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE | | AND COMPLIANCE. | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | CONSTRUCTION PERIOD. | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | AND COMPLETE PROTECTION IS RETURNED. | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2015-04-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-04-09 |
Time |
13:47 |
Sent To |
|
|
Notes |
2015-04-09 14:00:37 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF | | THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE | | INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND | | ALL OTHER APPLICABLE CODES OR STANDARDS. | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 13, 2010 EDITION. | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 72, 2010 EDITION. | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 241, 2009 EDITION. | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 10, 2010 EDITION. | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | 2) THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF | | THE FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE | | AND COMPLIANCE. | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | CONSTRUCTION PERIOD. | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | AND COMPLETE PROTECTION IS RETURNED. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-05-27 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-05-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2015-05-20 |
Time |
|
Sent To |
E |
|
Notes |
2015-05-21 16:17:17 | M. ALBARRAN'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-05-07 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-05-07 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-04-02 |
Time |
12:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2015-04-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-04-23 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-04-23 |
Time |
17:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2015-04-12 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-12 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-12 |
Time |
07:20 |
Sent To |
|
|
Notes |
|
|
|