Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-04-03 Cont ID  
Sent By jwitmer Date 2015-04-03 Time 12:56 Rev Time  
Received By jwitmer Date 2015-04-03 Time   Sent To  
Notes
2015-04-03 11:29:02BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15031327
 ADD: 709 8TH. ST.
 CONT: LOWES HOME CENTER
 TEL: (
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRIDAY APRIL 03/2015
 ACTION: DENIED
  
 1) THE SUBMITTED FLOOR PLANS DESCRIPTION OF PROPERTY
 DOES NOT MATCH THAT OF THE PROPERTY APPRAISERS OFFICE.
 THE FLOOR PLAN LIST THIS STRUCTUE AS A CORNER
 TOWNHOUSE, THIS STRUCTURE IS A SINGLE FAMILY RESIDENCE.
 DISCREPANCY IN PLANS. 107.2.1.3 ADDITIONAL INFORMATION
 REQUIRED.
  
 2) THERE IS A OPENING SCHEDULE WITH 1-18 OPENINGS
 LISTED. THE SCHEDULE DOES NOT LIST WHICH OPENING IS A
 WINDOW AND OR DOOR? ADDITIONAL INFORMATION IS REQUIRED.
 THE SECOND ISSUE WITH THE SUBMITTED FLOOR PLAN DOES NOT
 INDICATE THE ROOM USAGE, BEDROOMS AND COMPLIANCE WITH
 2010 FBC-R R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED.
 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND
 RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING
 OF 5.7 SQUARE FEET (0.530 M2).
 EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM
 NET CLEAR OPENING OF 5 SQUARE FEET (0.465 M2).
 R310.1.2 MINIMUM OPENING HEIGHT.
 THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES
 (610 MM).
 R310.1.3 MINIMUM OPENING WIDTH.
 THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES
 (508 MM).
  
 THE OTHER ISSUE IS THE SCHEDULE NOR THE FLOOR PLAN
 INDICATES THE WINDOWS ARE OR ARE NOT THE SAME TYPE OF
 WINDOW (CASEMENT VS. SINGLE HUNG) .
  
 3) PLEASE PROVIDE WIND DESIGN CRITERIA. WIND DESIGN
 CRITERIA
 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 3.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 3.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 3.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 3.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 3.5) COMPONENTS & CLADDING PRESSURES POSITIVE &
 NEGATIVE TABLE 1609.2(2) .
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-04-14 Cont ID  
Sent By fmittner Date 2015-04-14 Time 14:37 Rev Time 0.00
Received By fmittner Date 2015-04-14 Time 14:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-14 Cont ID  
Sent By cpuell Date 2015-04-14 Time 15:09 Rev Time 0.00
Received By cpuell Date 2015-03-30 Time 15:26 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved