Plan Review Details - Permit 15031194
Plan Review Stops For Permit 15031194
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-04-03 Cont ID  
Sent By jwitmer Date 2015-04-03 Time 12:57 Rev Time 0.00
Received By jwitmer Date 2015-04-03 Time 12:56 Sent To B
Notes
2015-04-03 12:57:47THE DESIGNER OF RECORD CAME IN AND RED (BLUE) LINED
 PLANS. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-04-02 Cont ID  
Sent By jwitmer Date 2015-04-02 Time 09:29 Rev Time  
Received By jwitmer Date 2015-04-02 Time 07:31 Sent To  
Notes
2015-04-02 09:29:31 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15031194
 ADD: 777 S. FLAGLER DR. SUITE # 136
 CONT: JIM RAPP
 TEL: (561)248-6411
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
 1ST REVIEW
 DATE: THURS. APRIL 02/2015
 ACTION: DENIED
  
 1) SHEET A2 OFFICE # 4 IS NEW AND HAS (2) INSWING
 DOORS, THE NEW DOORS DO NOT PROVIDE IF THEY ARE 3'-0"
 OR 2'-10" EACH. DEPENDING ON THE SIZE OF THE DOOR
 COMPLIANCE WITH MAY OR MAY NOT BE ACHIEVED, 2010
 FBC-ACCESSIBILITY CODE 404.2.6 DOORS IN SERIES.
  
 2) SHEET A2. NEW RESTROOM( NOT BATHROOM) IN THE OLD
 SERVER LOCATION, IS NOT DIMENSIONED. IT APPEARS THIS
 NEW RESTSROOM IS DESIGNED AS A ACCESSIBLE RESTROOM WITH
 PEDISTALL SINK AND GRAB BARS, THE MINIMUM DIMENSION
 WITH THE FIXTURES ON THE BACK WALL IS 7'-1" WITH THE
 LAV CENTERED 15 INCHES FROM WALL LAV OVERALL DIMENSION
 OF 19 INCHES IN WIDTH WILL GIVE COMPLIANCE OF 60 INCHES
 CLEARANCE IN COMPLIANCE WITH FBC-ACCESSIBILITY CODE
 604.3.2.
  
 3)SHEET A2. THE NEW RESTROOM AND PRIVATE OFFICE SHOWS
 NEW GRAB BARS BEING INSTALLED ON THE BACK AND SIDE
 WALLS. THE PLANS DO NOT PROVIDE ELEVATIONS WITH THE
 REQUIRED DIMENSIONS FOR THE GRAB BARS NOR DOES THE
 PLANS PROVIDE THE STRENGHT REQUIREMENTS FOR THE
 BACKING.
 2010 FBC-ACCESSIBILITY CODE 604.5.1, 604.5.2 & 609.8
 STRUCTURAL STRENGHT.
  
 4) SHEET A2.THE CONFERENCE ROOM TO THE RIGHT OF THE
 PAGE SHOWS A KITCHEN IN THIS ROOM. NOTE WHEN A KITCHEN
 IS IN A COMMERCIAL APPLICATION COMPLIANCE WITH 2010
 FBC-B F] 904.2.1 COMMERCIAL HOOD AND DUCT SYSTEMS. EACH
 REQUIRED COMMERCIAL KITCHEN EXHAUST HOOD AND DUCT
 SYSTEM REQUIRED BY THE FLORIDA FIRE PREVENTION CODE OR
 CHAPTER 5 OF THE FLORIDA BUILDING CODE, MECHANICAL TO
 HAVE A TYPE I HOOD SHALL BE PROTECTED WITH AN APPROVED
 AUTOMATIC FIRE-EXTINGUISHING SYSTEM INSTALLED IN
 ACCORDANCE WITH THIS CODE.
  
 5) SHEET A2. BEHIND THE AREA OF ALTERATIONS IS A
 CORRIDOR WITH (2) EXISTING DOORS THAT DO NOT COMPLY
 WITH 2010 FBC-ACCESSIBILITY CODE 404.2.4. PLEASE EITHER
 SHOW COMPLIANCE WITH THE CODE SECTION PROVIDED OR
 PRODUCE A LETTER SHOWING THE CONTRACTOR HAS MET THE
 COST ASSOCIATED WITH DISPROPORTIONATE COST. NOTE THE
 ORDER OF EXPENDITURES ASSOCIATED IN ACCESSIBLE
 UPGRADES, AND WHAT ITEMS CAN BE INCLUDED. 202.4.1
 DISPROPORTIONATE COST.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-31 Cont ID  
Sent By rlecky Date 2015-03-31 Time 13:49 Rev Time 0.00
Received By rlecky Date 2015-03-31 Time 13:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-03-30 Cont ID  
Sent By pleduc Date 2015-03-30 Time   Rev Time 0.00
Received By pleduc Date 2015-03-27 Time 15:36 Sent To  
Notes
2015-03-30 11:41:04THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PROVISO:
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE.
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-04 Cont ID  
Sent By hmoser Date 2015-04-04 Time 10:17 Rev Time 0.00
Received By hmoser Date 2015-03-26 Time 17:02 Sent To  
Notes
2015-03-26 17:02:26****EXPEDITED****
 B25
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-04-04 Cont ID  
Sent By hmoser Date 2015-04-04 Time 10:17 Rev Time 0.00
Received By hmoser Date 2015-04-04 Time 09:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-04-06 Cont ID  
Sent By tklarge Date 2015-04-04 Time 04:35 Rev Time 0.00
Received By tklarge Date 2015-04-04 Time 03:28 Sent To  
Notes
***NONE***