Plan Review Details - Permit 15031053
Plan Review Stops For Permit 15031053 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-04-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-04-23 |
Time |
17:11 |
Rev Time |
|
Received By |
jwitmer |
Date |
2015-04-23 |
Time |
|
Sent To |
|
|
Notes |
2015-04-23 17:13:30 | PLEASE SEE FIRES COMMENT ABOUT CARD READERS IN | | STAIRWELLS. 2010 FBC-B 1022.4 PENETRATIONS. | | PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT | | ENCLOSURE ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR INDEPENDENT | | VENTILATION OR PRESSURIZATION, SPRINKLER PIPING, | | STANDPIPES, ELECTRICAL RACEWAY FOR FIRE DEPARTMENT | | COMMUNICATION SYSTEMS AND ELECTRICAL RACEWAY SERVING | | THE EXIT ENCLOSURE AND TERMINATING AT A STEEL BOX NOT | | EXCEEDING 16 SQUARE INCHES (0.010 M2). SUCH | | PENETRATIONS SHALL BE PROTECTED IN ACCORDANCE WITH | | SECTION 713. THERE SHALL BE NO PENETRATIONS OR | | COMMUNICATION OPENINGS, WHETHER PROTECTED OR NOT, | | BETWEEN ADJACENT EXIT ENCLOSURES. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2015-04-23 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-04-23 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-04-23 |
Time |
12:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2015-04-17 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2015-04-17 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2015-04-17 |
Time |
11:32 |
Sent To |
|
|
Notes |
2015-04-17 13:38:18 | 4847 FRED GLADSTONE DRIVE | | PERMIT #15031053 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SHEET E-E501: SEVERAL STAIRS ON SEVERAL LEVELS INDICATE | | THE USE OF CARD READERS AND OCCUPANT SENSORS LOCATED | | WITHIN THE FIRE RATED EXIT ENCLOSURE. PER NFPA 101 | | SECTION 7.1.3.2.1, PENETRATIONS INTO, AND OPENINGS | | THROUGH, AN EXIT ENCLOSURE ASSEMBLY SHALL BE LIMITED TO | | DOOR ASSEMBLIES FROM NORMALLY OCCUPIED SPACES AND | | CORRIDORS, REQUIRED EXIT DOOR OPENINGS, ELECTRICAL | | CONDUIT SERVING THE EXIT ENCLOSURE, DUCTWORK AND | | EQUIPMENT NECESSARY FOR INDEPENDENT STAIR | | PRESSURIZATION, WATER OR STEAM PIPING NECESSARY FOR THE | | HEATING OR COOLING OF THE EXIT ENCLOSURE, SPRINKLER | | PIPING, STANDPIPES, AND PENETRATIONS FOR FIRE ALARM | | CIRCUITS, WHERE THE CIRCUITS ARE INSTALLED IN METAL | | CONDUIT AND THE PENETRATIONS ARE PROTECTED. | | | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-05-02 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-05-02 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-03-25 |
Time |
08:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2015-05-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2015-05-02 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2015-05-02 |
Time |
09:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-05-02 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-20 |
Time |
06:03 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-19 |
Time |
10:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-04-20 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2015-04-20 |
Time |
12:16 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2015-04-20 |
Time |
12:16 |
Sent To |
|
|
Notes |
2015-04-20 12:17:24 | THE LANDSCAPE AND FENCE/GATE REQUIRE SEPARATE PERMITS | | WITH PLANS AND ARE NOT APPROVED AS PART OF THIS PERMIT | | REVISION. | | |
|
|
|