Plan Review Details - Permit 15031039
Plan Review Stops For Permit 15031039
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2015-04-12 Cont ID  
Sent By shill Date 2015-04-12 Time 11:03 Rev Time 0.00
Received By shill Date 2015-04-12 Time 11:03 Sent To  
Notes
2015-04-12 11:03:42ADDRESS HAS BEEN CHANGED FROM 650 OKEECHOBEE
 (CONVENTION CENTER ADDRESS) TO 1099 FLORIDA AVENUE (NEW
 ADDRESS FOR PARKING GARAGE)
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-05-18 Cont ID  
Sent By shill Date 2015-05-18 Time 16:59 Rev Time 0.00
Received By shill Date 2015-05-18 Time 16:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-25 Cont ID  
Sent By shill Date 2015-03-25 Time 09:46 Rev Time 0.00
Received By shill Date 2015-03-25 Time 09:46 Sent To  
Notes
2015-03-25 10:51:56****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. GEOTECHNICAL REPORT REQUIRED FOR VIBROFLOTATION, FBC
 1803.1.
  
 2. PROVIDE A PLAN WHICH DOCUMENTS LOCATION OF
 VIBROFLOTATION, FBC 107.
  
 3. PROVIDE INFORMATION TO DOCUMENT THE INDIVIDUAL AND
 COMPANY RESPONSIBLE FOR MONITORING THE VIBROFLOTATION.
 A CONTRACT IS RECOMMENDED BUT OTHER FORMS OF
 DOCUMENTATION WOULD ALSO BE CONSIDERED, FBC 1803, FBC
 107.
  
 4. IT IS RECOMMENDED THAT CONTRACTOR ADVISE THE
 RESIDENTS ADJACENT TO PROPOSED CONSTRUCTION OF WORK
 PRIOR TO COMMENCEMENT. PROPERTY OWNERS IN THE ADJACENT
 TOWNHOUSES HAVE EXPRESSED CONCERN REGARDING THE
 STRUCTURAL IMPACT OF CONSTRUCTION AND CONTRACTOR HAS
 EXPLAINED HOW THIS WILL BE ADDRESSED, FBC 3307.1. PER
 CONTRACTOR, A STRUCTURAL ANALYSIS OF THE ADJACENT
 STRUCTURES WILL BE PERFORMED AND DOCUMENTED PRIOR TO
 CONSTRUCTION.
  
 IF THE ANALYSIS DISCUSSED IS NOT DONE PRIOR TO ISSUANCE
 OF THIS VIBROFLOTATION PERMIT, CONTRACTOR IS TO PROVIDE
 A LETTER STATING WHY THIS IS NOT NECESSARY AT THIS
 TIME. IT IS RECOMMENDED THAT CONTRACTOR PROVIDE
 INFORMATION REGARDING THE TIMING AND NATURE OF THIS
 PERMIT TO THE RESIDENTS PRIOR TO COMMENCEMENT.
  
 5. ADVISORY ONLY - CONSTRUCTION HOURS ARE 7AM - 7PM
 MONDAY THROUGH FRIDAY; 8AM - 8PM WEEKENDS, CITY OF WEST
 PALM BEACH MUNICIPAL CODE SECTION 34-72. A WRITTEN
 EXCEPTION MAY BE GRANTED BY THE BUILDING OFFICIAL;
 PLEASE SUBMIT ANY SUCH REQUESTS (IF NEEDED) TIMELY TO
 [email protected], CC [email protected] AND [email protected].
  
 6. ADVISORY ONLY - THE VALUE HAS BEEN ADJUSTED TO BE
 CONSISTENT WITH THE CONTRACTOR SUPPLIED "COST ESTIMATE
 OF WORK" (FROM $200,000 TO $235,330). IF THIS IS NOT
 CORRECT, PLEASE ADVISE, PREFERABLY BEFORE THE FEES ARE
 PAID.
  
 7. ADVISORY ONLY - A UNIQUE ADDRESS WILL BE ASSIGNED TO
 THIS STRUCTURE. CONTRACTOR WILL BE NOTIFIED OF THE NEW
 ADDRESS WHEN ASSIGNED.
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2015-05-20 Cont ID  
Sent By cranford Date 2015-05-20 Time 13:51 Rev Time 0.00
Received By cranford Date 2015-05-20 Time 13:50 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2015-04-21 Cont ID  
Sent By cranford Date 2015-04-21 Time 09:26 Rev Time 0.00
Received By cranford Date 2015-04-21 Time 08:31 Sent To I
Notes
2015-05-14 08:30:01BOND RECEIVED 5/12/2015
2015-04-21 09:26:401. PLEASE SUBMIT A STORMWATER POLLUTANT PROTECTION PLAN
 (SWPPP) FOR THE ENGINEERING DEPARTMENT?S REVIEW AND
 APPROVAL. (CODE OF ORDINANCES. SECTION 94-450)
  
 2. APPLICANTS FOR DEMOLITION AND/OR BUILDING PERMITS TO
 PERFORM LAND DISTURBING CONSTRUCTION AND LAND
 DEVELOPMENT ACTIVITIES SHALL SUBMIT A BOND OR DEPOSIT
 IN AN AMOUNT COVERING THE COST ASSOCIATED WITH
 IMPLEMENTATION OF THE SWPPP LAND STABILIZATION OF THE
 SITE. PLEASE SUBMIT A COPY OF THE AUTOCALC CERTIFIED
 COST ESTIMATE FORM AND A BOND FOR THE LAND
 STABILIZATION OF THE SITE. THE AUTOCALC SPREADSHEET CAN
 BE DOWNLOADED AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ THE
 BOND WILL BE RELEASED UPON APPROVED INSPECTION OF
 TIE-BEAMS OR SIMILAR VERTICAL CONSTRUCTION. (CITY CODE
 SECTION 94-450)
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2015-04-17 Cont ID  
Sent By shill Date 2015-04-17 Time 12:50 Rev Time 0.00
Received By shill Date 2015-04-17 Time 12:50 Sent To  
Notes
2015-04-17 12:50:29NO FIRE REVIEW REQUIRED PER PETER LEDUC
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-06-18 Cont ID  
Sent By lmarchan Date 2015-06-18 Time 10:43 Rev Time 0.00
Received By lmarchan Date 2015-06-09 Time   Sent To  
Notes
2015-06-09 18:12:35SENT TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-05-20 Cont ID  
Sent By cranford Date 2015-05-20 Time 13:51 Rev Time 0.00
Received By cranford Date 2015-05-13 Time 07:49 Sent To  
Notes
2015-05-18 16:59:575/18/15 PERMIT APPLICATION PACKAGE ON SH DESK - ERIC S
 WILL PICK UP TO REVIEW
  
2015-05-15 08:39:19***EXPEDITED***
2015-05-14 07:49:53RE-SUBMITTAL SENT TO ZONING SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-21 Cont ID  
Sent By cranford Date 2015-04-21 Time 09:27 Rev Time 0.00
Received By cranford Date 2015-03-25 Time 10:57 Sent To  
Notes
2015-03-25 10:57:383/25 TO ZONING
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status N Date 2015-03-25 Cont ID  
Sent By shill Date 2015-03-25 Time 10:52 Rev Time 0.00
Received By shill Date 2015-03-25 Time 10:52 Sent To  
Notes
2015-03-25 10:52:49NOT REQUIRED AT THIS TIME PER RB.
 MONITORING OF VIBROFLOTATION BY A SPECIALTY ENGINEER
 WILL BE DOCUMENTED.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2015-06-17 Cont ID  
Sent By eschneid Date 2015-06-17 Time 10:18 Rev Time 0.50
Received By eschneid Date 2015-06-17 Time 10:18 Sent To PC
Notes
2015-06-17 10:19:23TREES IDENTIFIED AS PRESERVED SHALL BE PROTECTED AND
 TREES IDENTIFIED AS RELOCATED SHALL BE MOVED TO THE
 INDICATED LOCATIONS.
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 2015-05-19 Cont ID  
Sent By eschneid Date 2015-05-19 Time 17:59 Rev Time 0.50
Received By eschneid Date 2015-05-19 Time 17:55 Sent To ENG
Notes
2015-05-19 18:23:56FAILED
  
 1. THANK YOU FOR PROVIDING THE LANDSCAPE PLANS FOR THE
 PROJECT. PLEASE SEE THE COMMENTS BELOW FOR CORRECTIONS
 THAT NEED TO BE MADE TO THE PLANS:
  
 A. MAHOGANY (EXCELLENT CONDITION) TREE NO. 8 SHOWN AS
 REMAINING ON THE EXISTING CONDITION/TREE RELOCATION
 PLAN SHALL BE INCLUDED ON THE LANDSCAPE PLAN.
  
 B. LIVE OAK (GOOD CONDITION) TREE NO. 32 IS SHOWN AS
 RELOCATED ON THE EXISTING CONDITION/TREE RELOCATION
 PLAN, YET IT IS SHOWN REMAINING IN PLACE ON THE
 LANDSCAPE PLAN. THIS TREE SEEMS TO BE IN CONFLICT WITH
 PROPOSED 8 IN. GV #3, 8 IN. DCDA #1 AND 8 IN. PIV #1.
  
 C. MAHOGANY (EXCELLENT AND GOOD CONDITION) TREE NOS.
 14, 15, 24, 28, 38 AND 122 AND LIVE OAK (GOOD
 CONDITION) TREE NOS. 77 AND 86 ARE SHOWN AS BEING
 REMOVED ON THE ON THE EXISTING CONDITION/TREE
 RELOCATION PLAN. THESE TREES SHALL BE RELOCATED AND NOT
 DESTROYED. THE MAHOGANY TREES SHALL BE USED TO FILL IN
 THE MISSING GAPS ALONG THE SOUTH BUFFER AND THE OAK
 TREES SHALL BE USED IN LIEU OF PURCHASING NEW OAK
 TREES.
  
 2. PLEASE SHOW THE LIMITS OF WORK UNDER THE PHASE I
 VIBROFLOTATION PERMIT ON THE SUBMITTED LANDSCAPE PLANS
 SO IT IS CLEAR WHICH TREES WILL BE FENCED FOR
 PRESERVATION AND WHICH TREES WILL BE RELOCATED TO THE
 SOUTHERN BUFFER AREA THAT WILL NEED TO BE CONSTRUCTED
 PRIOR TO THE COMMENCEMENT OF THE VIBROFLOTATION WORK.
 THE LIMITS OF WORK ON THIS PLAN WILL NOT INCLUDE THE
 RIGHT-OF-WAY THAT THE PREVIOUSLY SUBMITTED PLANS
 SHOWED. PLEASE NOTE THAT ANY PORTIONS OF THE CONVENTION
 CENTER PARKING LOT WHICH WILL REMAIN OPEN SHALL INCLUDE
 THE REQUIRED LANDSCAPE ISLANDS.
  
 3. THE FICUS HEDGE THAT IS LOCATED ALONG THE SOUTH AND
 EAST PROPERTY WALLS IS IN BAD HEALTH AND SHALL BE
 REMOVED AS PART OF THIS PHASE. IT SHALL BE REPLACED
 WITH A NATIVE HEDGE AS PART OF THE LANDSCAPE
 INSTALLATION COMPLETION FOR THE SITE.
  
 4. PLEASE VERIFY WITH THE CONSTRUCTION SERVICES
 DIVISION IF THE SOUTHERN BUFFER AREA MAY BE INCLUDED
 WITH THIS PERMIT, REQUIRES A SEPARATE PERMIT, OR IF IT
 IS HANDLED VIA THE ENGINEERING PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 1 Status F Date 2015-04-17 Cont ID  
Sent By eschneid Date 2015-04-17 Time 15:15 Rev Time 0.50
Received By eschneid Date 2015-04-17 Time 15:15 Sent To ENG
Notes
2015-04-17 15:43:15FAILED
  
 1) THE SUBMITTED LANDSCAPE DEMOLITION PLAN INDICATES
 THAT THE ENTIRE LANDSCAPE WITHIN THE HATCHED AREA WILL
 BE DEMOLISHED, TO INCLUDE THE TREES THAT ARE TO REMAIN
 AND THAT ARE TO BE RELOCATED.
  
 2) NO INFORMATION HAS BEEN PROVIDED AS TO HOW THE TREES
 DESIGNATED TO BE PRESERVED WILL BE PROTECTED FROM
 CONSTRUCTION.
  
 3) THE TREES DESIGNATED FOR RELOCATION ARE NOT TO BE
 MOVED OFF-SITE FOR STORAGE. THE SOUTHERN TREE BUFFER
 SHALL BE CONSTRUCTED TO HOLD THE RELOCATED TREES AND
 THE TREES SHALL BE RELOCATED TO THIS LOCATION AS PART
 OF THE PHASE 1 WORK.
  
 4) TRAILER NO. 2 IS BEING SHOWN INTERFERING WITH THE
 TREES THAT ARE TO BE PRESERVED IN PLACE ALONG THE
 SOUTHERN BUFFER OF THE SITE.
  
 5) THERE IS WORK BEING SHOWN IN THE FLORIDA AVENUE
 RIGHT-OF-WAY. THE CONTRACTOR SHALL SECURE A
 RIGHT-OF-WAY PERMIT PRIOR TO ZONING APPROVING THIS
 PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.