Plan Review Stops For Permit 15030748 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2015-03-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-03-25 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-03-25 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2015-06-23 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-06-23 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-06-23 |
Time |
14:01 |
Sent To |
Z |
|
Notes |
2015-06-23 14:38:14 | PER SHIRLEY, I PUT ON HER STACK |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2015-06-18 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-06-18 |
Time |
19:26 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-06-18 |
Time |
18:59 |
Sent To |
I |
|
Notes |
2015-06-18 19:30:56 | SECOND REVIEW FAILED DUE TO INCOMPLETE SUBMITTAL. | | ELECTRICAL PG. E1.2 SITE PLAN WAS NOT PROVIDED | | THOUGH ALL OF THE PREVIOUSLY REQUESTED INFORMATION IS | | PROVIDED, PG. E0.1 INDICATES THAT THERE IS A MISSING | | PAGE WHICH MAY HAVE PERTINENT INFORMATION IN ADDITION | | TO THE LOCATION OF THE APPARATUS. | | SUBMIT A SITE PLAN FOR APPROVAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-05-05 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-05-05 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-05-05 |
Time |
12:31 |
Sent To |
|
|
Notes |
2015-05-05 14:12:42 | 15030748 | | 1590 CAMERON SAMUEL LANE | | LAKE FOUNTAINS | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | REVIEW COMMENTS | | | | PROVIDE AN ELECTRICAL RISER PLAN FOR EACH FOUNTAIN. NEC | | 215.5 | | | | PROVIDE THE LOCATION OF EACH DISCONNECTING MEANS. NEC | | 682.14 | | | | PROVIDE A SITE PLAN WHICH SHOWS THE LOCATION OF ALL | | ELECTICAL EQUIPMENT AND UNDERGROUND WIRING. NEC 682.11 | | | | INDICATE THE LOCATION OF THE ELECTRICAL DATUM PLANE ON | | THE SITE PLAN FOR EACH INSTALLATION. NEC 682.10 | | | | PROVIDE A CONSTRUCTION DETAIL AND LOCATION FOR EACH | | EQUIPOTENTIAL PLANE REQUIRED FOR THE SERVICE, | | DISCONNECTS AND CONTROL EQUIPMENT. NEC 682.33 | | | | NOTE: SEPARATE PERMITS WITH A SEPARATE ADDRESS IS | | REQUIRED FOR EACH FOUNTAIN. PROVIDE THREE SEPARATE | | PERMITS FROM AN ELECTRICAL CONTRACTOR FOR THIS | | INSTALLATION. PROVIDE A COPY OF THE CONTRACT FOR THE | | COMPLETE INSTALLATION, MATERIALS AND LABOR. | | | | ROBERT LECKY | | ELECTRICAL PLANS REVIEW | | 561-373-3701 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-06-24 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-06-24 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-06-22 |
Time |
09:40 |
Sent To |
|
|
Notes |
2015-06-24 08:58:39 | 6/24/15 - SHIRLEY RETURNED THIS TO ME APPROVED. | | CONTRACTOR NOTIFIED VIA EMAIL. SENT TO SMALL READY BIN | | "K". MA | 2015-06-23 09:41:01 | RE-SUBMITTAL SENT TO MIKE ALBARRAN FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-06-18 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2015-06-18 |
Time |
19:39 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2015-06-05 |
Time |
|
Sent To |
|
|
Notes |
2015-06-18 19:39:51 | WAITING FOR SITE PLANS | | SENT TO SMALL DENIED BIN "V" | 2015-06-13 18:51:32 | 6/13 TO R LECKY'S DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-05-05 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2015-05-05 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2015-03-19 |
Time |
07:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2015-03-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2015-03-25 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2015-03-25 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-06-11 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2015-06-18 |
Time |
19:40 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2015-06-11 |
Time |
13:56 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
avann |
Date |
2015-04-09 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2015-04-09 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|