Plan Review Details - Permit 15030629
Plan Review Stops For Permit 15030629
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-04-01 Cont ID  
Sent By jwitmer Date 2015-04-01 Time 07:54 Rev Time  
Received By jwitmer Date 2015-03-31 Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-04-10 Cont ID  
Sent By dhayes Date 2015-04-10 Time 08:10 Rev Time 0.00
Received By dhayes Date 2015-04-10 Time 07:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-05-05 Cont ID  
Sent By wjolin Date 2015-05-05 Time 12:29 Rev Time 0.00
Received By wjolin Date 2015-05-05 Time 12:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-04-15 Cont ID  
Sent By wjolin Date 2015-04-15 Time 16:46 Rev Time 0.00
Received By wjolin Date 2015-04-15 Time 14:44 Sent To  
Notes
2015-04-15 16:11:208100 IBIS BOULEVARD
 TRACKING #15030629
 MASTER #14050097
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET GI101: ADD "MERCANTILE" USE TO THE BUILDING CODE
 ANALYSIS MATRIX.
  
 SHEET GI101: THERE NO EXIT SIGNS PROVIDED IN CORRIDOR
 E117. THE THREE SETS OF DOORS IN CORRIDOR E117 APPEAR
 TO BE LOCATED TO BE ABLE TO LOCK/SEGREGATE THE
 MERCANTILE, BUSINESS AND ASSEMBLY OCCUPANCIES FROM
 EACHOTHER. ENSURE EXIT ACCESS DOORS ARE EQUIPPED WITH
 PANIC HARDWARE.
  
 ELECTRICAL: NO REVISED FIRE ALARM DRAWINGS SUBMITTED
 FOR THE REVISED BUSINESS AND MERCANTILE (GOLF SHOP)
 AREAS.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-05-26 Cont ID  
Sent By hmoser Date 2015-05-26 Time 11:24 Rev Time 0.00
Received By hmoser Date 2015-04-29 Time 10:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-16 Cont ID  
Sent By shill Date 2015-04-16 Time 18:12 Rev Time 0.00
Received By shill Date 2015-03-20 Time 09:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-05-26 Cont ID  
Sent By hmoser Date 2015-05-26 Time 11:24 Rev Time 0.00
Received By hmoser Date 2015-05-26 Time 10:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-04-11 Cont ID  
Sent By hmoser Date 2015-04-11 Time 08:30 Rev Time 0.00
Received By hmoser Date 2015-04-11 Time 07:47 Sent To  
Notes
2015-04-11 08:30:22PLAN DENIED
 NOTE #9 CONDENSATE CAN NOT INTO FLOOR SINK UNLESS FLOOR
 SINK IS TIED INTO
 STORM WATER PER SECTION .90-125 # 5 WEST PALM BEACH
 FLORIDA CODE OF ORDINANCE. OR COMPLY WITH SECTION 307
 2010 FBC (M)
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status N Date 2015-05-21 Cont ID  
Sent By tklarge Date 2015-05-21 Time 06:24 Rev Time 0.00
Received By tklarge Date 2015-05-16 Time 10:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2015-04-28 Cont ID  
Sent By tklarge Date 2015-04-15 Time 14:46 Rev Time 0.00
Received By tklarge Date 2015-04-11 Time 11:33 Sent To  
Notes
2015-04-15 14:46:45NO PLUMBING DRAWINGS SUBMITTED.
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2015-06-23 Cont ID  
Sent By skennedy Date 2015-06-23 Time 08:33 Rev Time 0.00
Received By skennedy Date 2015-06-23 Time 08:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2015-06-08 Cont ID  
Sent By rbrown Date 2015-06-08 Time 21:00 Rev Time 0.00
Received By rbrown Date 2015-06-08 Time 22:56 Sent To  
Notes
2015-06-08 22:59:01ELECTRONIC SIGNATURE REVIEW
 *******DENIED*******
 ROBERT BROWN (561) 805 6652
 E-MAIL: [email protected]
  
 1) THE CIVIL ENGINEERING, ELECTRICAL ENGINEERING AND
 MECHANICAL ENGINEERING PLAN SHEETS DO NOT SHOW THE NAME
 AND LICENSE NUMBER OF THE CIVIL, ELECTRICAL, OR
 MECHANICAL ENGINEERS OF RECORD. THIS IS A REQUIREMENT
 OF THE FOLLOWING SECTION FROM FLORIDA BUILDING CODE,
 CITY OF WEST PALM BEACH AMENDMENTS TO CHAPTER 1,
 ADMINISTRATIVE.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE
 SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS
 CODE AND RELEVANT LAWS, ORDINANCES, RULES
 AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE
 QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL
 CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN. (SEE ALSO SECTION 107.3.5).
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6652 ROBERT BROWN
 E-MAIL: [email protected]