Plan Review Stops For Permit 15030623 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-08-31 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-08-31 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-08-31 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-07-20 |
|
|
Cont ID |
|
Sent By |
R MCDOUG |
Date |
2015-07-20 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-07-17 |
Time |
16:38 |
Sent To |
|
|
Notes |
2015-07-20 16:12:06 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE CLASSIFICATION OF WORK ON THE COVER SHEET | | SPECIFIES THIS AS A LEVEL 1 ALTERATION. THE PLANS | | INDICATE THAT THE SPACE HAS BEEN RECONFIGURED AND DOORS | | AND WINDOWS HAVE BEEN ADDED OR ELIMINATED. THIS PROJECT | | MEETS THE REQUIREMENTS FOR A LEVEL 2 ALTERATION. IF THE | | WORK AREA EXCEEDS 50 PERCENT OF THE AGGREGATE AREA OF | | THE BUILDING, THEN IT IS A LEVEL 3 ALTERATION. FBC | | EXISTING BUILDING 401.4 | | | | 2) SPECIFY THE WIND DESIGN CRITERIA AND THE REQUIRED | | DESIGN PRESSURES FOR THE (2) NEW EXTERIOR DOORS AND (1) | | WINDOW. FBC-R301.2.1 | | | | 3) FBC 107.3.4 - PROVIDE TWO COMPLETE SETS OF PRODUCT | | APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9N-3 THAT HAVE BEEN REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD. | | | | 4) THE ONE SET OF PRODUCT APPROVAL INSTALLATION | | DOCUMENTS THAT WERE SUBMITTED FOR THE JELD-WEN SLIDING | | PATIO DOOR DOES NOT HAVE A FLORIDA PRODUCT APPROVAL FL# | | ON THEM. SUBMIT THE COVER-SHEETS WITH THE FL#. | | | | 5) THE DOOR SCHEDULE ON SHEET A-200 FOR DOOR #1 | | SPECIFIES THE DOOR TYPE AS SLIDING AND SWING DOORS ARE | | INDICATED UNDER REMARKS FOR THIS DOOR. PRODUCT | | APPROVALS FOR BOTH EXTERIOR DOOR TYPES WERE SUBMITTED. | | PLEASE CLARIFY. FBC 107.2.1 | | | | 6) THE ENERGY FORM 402-2010 IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER/AGENT. FBC ENERGY 103.2.3.2 | | | | 7) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | ADDRESSED. | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-04-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-10 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-10 |
Time |
07:46 |
Sent To |
|
|
Notes |
2015-04-10 07:08:53 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | SHALL BE | | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. | | | | 2) FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | RECORDS MANAGEMENT. | | | | 3) FBC 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | STRUCTURES ON THE SITE. | | | | 4) FBC-R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | | 5) PROVIDE AN INTERIOR WALL SECTION OF THE WALL TO ROOF | | EXTENSION. SPECIFY THE FRAMING MATERIAL, CONNECTIONS | | AND FASTENERS THAT WILL BE USED. FBC 107.2.1 | | | | 7) PROVIDE A SECTION THROUGH THE ROOF / CEILING | | ASSEMBLY. SHOW THE TYPE AND LOCATION OF THE INSULATION | | THAT IS TO BE ADDED. SHOW ATTIC ATTIC ACCESS AND | | VENTILATION. FBC 107.2.1 | | | | 8) REMOVE ITEMS FROM THE SCOPE OF WORK LISTED ON THE | | PLAN THAT WILL NOT BE INCLUDED WITH THIS PERMIT. FBC | | 107.2.1 | | | | 9) THE PLANS THAT WERE SUBMITTED HAVE THE TITLE BLOCK | | OF AN ARCHITECT. FS 481 & FAC 61G1-16 REQUIRES PLANS | | THAT ARE SUBMITTED FROM AN ARCHITECT TO HAVE THEIR SEAL | | AND HANDWRITTEN SIGNATURE. | | | | IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | ADDRESSED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-07-20 |
|
|
Cont ID |
|
Sent By |
R MCDOUG |
Date |
2015-07-20 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-07-17 |
Time |
16:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-04-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-10 |
Time |
07:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-10 |
Time |
07:02 |
Sent To |
|
|
Notes |
2015-04-09 19:06:16 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 / 2008 NEC | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY ELECTRICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT TWO SETS OF ELECTRICAL PLANS. SHOWING | | COMPLIANCE WITH THE 2008 NEC FOR REQUIRED RECEPTALCES, | | LIGHTING OUTLETS AND PANEL LOCATION. PROVIDE A PANEL | | SCHEDULE AND INDICATE THE CIRCUIT NUMBERS ON THE PLANS. | | FBC 107.3.5.3 | | | | 2) FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | RECORDS MANAGEMENT. | | | | 3) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | 4) FBC-R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | LOCATED AS REQUIRED FOR NEW DWELLINGS. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2015-08-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-08-31 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-08-31 |
Time |
16:18 |
Sent To |
|
|
Notes |
2015-08-31 16:45:36 | APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL | | RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF | | RE-INSPECTION FEE(S). SUBMIT (2) SETS OF REVISED GAS | | RISER DIAGRAMS FOR APPROVAL PRIOR TO FIRST GAS | | INSPECTION. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2015-07-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-07-17 |
Time |
17:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-07-17 |
Time |
16:38 |
Sent To |
|
|
Notes |
2015-07-17 18:08:16 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | GAS REVIEW DENIED | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THERE IS A DISCREPANCY BETWEEN THE TANKLESS WATER | | HEATER BTUS ON THE PLANS. SHEET P-1 SPECIFIES 120,000 | | BTUS AND P-2 HAS 199,000 BTUS. SUBMIT THE | | MANUFACTURER'S SPECIFICATIONS, LISTING AND INSTALLATION | | INSTRUCTIONS FOR THE TANKLESS WATER HEATER THAT WILL BE | | INSTALLED. FBC 107.2.1 AND FBC-R G2413.2 | | | | 2) ON SHEET P-2 THE TOTAL BTU LOAD WOULD BE 279,000 | | BTUS FOR THE SUM OF 80,000 AND 199,000 BTUS. FBC | | 107.2.1 | | | | 3) USING THE LONGEST LENGTH SIZING METHOD, THE 3/4" PE | | PIPE SUPPLYING THE 199,000 BTU TANKLESS WATER HEATER IS | | TOO SMALL. AT 50 FEET THE CAPACITY IS 169,000 BTUS. | | FBC-R 2413.4.1 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2015-08-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-08-31 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-08-24 |
Time |
10:07 |
Sent To |
B |
|
Notes |
2015-08-25 09:19:04 | CORRECTION NOTED. | 2015-08-24 10:08:30 | PLANS STILL SHOW 2 PAIRS OF DOUBLE DOORS ON FRONT, NOT | | APPROVED BY HPB |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2015-07-21 |
|
|
Cont ID |
|
Sent By |
F MITTNE |
Date |
2015-07-21 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-07-21 |
Time |
13:16 |
Sent To |
|
|
Notes |
2015-07-21 13:17:20 | HPB ON 6/23/15 DID NOT APPROVE CHANGE OF FRONT DOOR | | FROM DOUBLE TO SINGLE NOR KNEE WALL REDUCATION. PLANS | | MUST BE REVISED. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-04-07 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-04-07 |
Time |
09:59 |
Sent To |
|
|
Notes |
2015-04-07 10:00:47 | PROPERTY IS CONTRIBUTING TO THE GRANDVIEW HEIGHT | | HISTORIC DISTRICT. SCOPE OF WORK DOES NOT INCLUDE | | EXTERIOR DOORS, YET REPRESENTED ON PLAN. REQUIRES | | SUBMITTAL OF COA. QUESTIONS CONTACT FRIEDERIKE MITTNER | | AT 822-1457. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-08-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-08-31 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-08-04 |
Time |
15:36 |
Sent To |
HIST |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-07-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2015-07-21 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2015-06-10 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-04-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-10 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-03-17 |
Time |
10:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2015-07-17 |
|
|
Cont ID |
|
Sent By |
R MCDOUG |
Date |
2015-07-17 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-07-17 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-09 |
Time |
18:41 |
Sent To |
|
|
Notes |
2015-04-09 18:44:14 | NO MECHANICAL WORK IS SHOWN ON THE PLANS AND NO | | MECHANICAL PERMIT WAS SUBMITTED. A SEPARATE PERMIT, | | APPLICATION AND REVIEW WILL BE REQUIRED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-07-17 |
|
|
Cont ID |
|
Sent By |
R MCDOUG |
Date |
2015-07-17 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-07-16 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
18:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-09 |
Time |
18:35 |
Sent To |
|
|
Notes |
2015-04-09 18:36:04 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT TWO SETS OF PLUMBING RISER DIAGRAMS. FBC | | 107.3.5.3 | | | | 2) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2015-07-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-07-21 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2015-07-21 |
Time |
13:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2015-04-07 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2015-04-07 |
Time |
|
Sent To |
|
|
Notes |
|
|