Plan Review Details - Permit 15030443
Plan Review Stops For Permit 15030443 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-05-13 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-05-13 |
Time |
16:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-04-06 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-07 |
Time |
05:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2015-04-06 |
Time |
10:15 |
Sent To |
E |
|
Notes |
2015-04-06 10:18:31 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. THIS PROJECT INCLUDES PLUMBING AND ELECTRICAL WORK. | | SUBMIT A PLAN WHICH INCLUDES ENTIRE SCOPE OF WORK. | | PLUMBING AND ELECTRICAL WILL BE SUB CONTRACTORS TO THIS | | PERMIT. INCREASE VALUE TO INCLUDE THE SUBCONTRACTORS, | | FBC 109. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-05-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2015-05-02 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-05-02 |
Time |
12:17 |
Sent To |
B |
|
Notes |
2015-05-02 12:26:10 | 4/6/2015 | | PROJECT: KITCHEN RENOVATION | | PERMIT#: 15030443 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN | | APPROVED PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | FEE(S). | | | | 1) ALL 125-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE | | RECEPTACLES INSTALLED IN THE LOCATIONS SPECIFIED IN (1) | | THROUGH (8) SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER | | PROTECTION FOR PERSONNEL. NEC 210.8(6) KITCHENS - WHERE | | THE RECEPTACLES ARE INSTALLED TO SERVE THE COUNTERTOP | | SURFACES. | | | | 2) VERIFY OR INSTALL SMOKE DETECTORS WHERE REQUIRED IN | | THE FBC. WHEN ALTERATIONS, REPAIRS, OR ADDITIONS | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. | | FBC-RESIDENTIAL 314 AND 315. | | | | 3) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER | | RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11 | | | | 4) VERIFY RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT | | NO POINT ALONG THE WALL LINE IS MORE THAN 600 MM (24 | | IN.) MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN | | THAT SPACE.NEC 210.52(C)(1) | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2015-04-06 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2015-04-06 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2015-04-06 |
Time |
12:30 |
Sent To |
P |
|
Notes |
2015-04-06 13:09:56 | 4/6/2015 | | PROJECT: KITCHEN RENOVATION | | PERMIT#: 15030443 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | 1ST ELECTRICAL PLAN REVIEW | | ACTION: DENIED | | | | 1) PROVIDE ELECTRICAL PLANS THAT INDICATE THE COMPLETE | | SCOPE OF WORK. INCLUDE ANY ELECTRICAL CIRCUITRY OR | | DEVICES IN THE WALL TO BE PARTIALLY DEMOLISHED AS WELL | | ALL ELECTRICAL CIRCUITRY IN THE KITCHEN EITHER EXISTING | | OR PROPOSED TO BE INSTALLED. IDENTIFY ON THE PLANS WHAT | | IS EXISTING TO REMAIN AND WHAT IS PROPOSD. | | A) PROVIDE A PANEL SCHEDULE AND A LOAD CALCULATION TO | | IDENTIFY ALL NEW LOADS OR CIRCUITRY PROPOSED. | | | | 2) VERIFY OR INSTALL SMOKE DETECTORS WHERE REQUIRED IN | | THE FBC. WHEN ALTERATIONS, REPAIRS, OR ADDITIONS | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. | | FBC-RESIDENTIAL 314 AND 315. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. SEE LINK: | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | REVIEW. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-05-13 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2015-05-13 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2015-04-28 |
Time |
12:35 |
Sent To |
|
|
Notes |
2015-04-28 12:36:09 | RE-SUBMITTAL SENT TO TIM LARGE FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
misc1 |
Date |
2015-04-07 |
Time |
05:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-03-12 |
Time |
08:14 |
Sent To |
B |
|
Notes |
2015-04-06 10:19:02 | TO ELEC | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2015-05-02 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-05-02 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-05-02 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2015-04-07 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2015-04-07 |
Time |
05:03 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2015-04-07 |
Time |
04:54 |
Sent To |
|
|
Notes |
2015-04-07 05:01:05 | 1) SUBMIT A SET OF PLANS THAT SHOWS THE ENTIRE SCOPE OF | | PLUMBING WORK TO BE DONE. WPB AMEND. TO 2010 FBC SEC. | | 107.2.1. | | 2) INDICATE ON PLANS IF THE PLUMBING FIXTURES BEING | | REPLACED ARE GOING BACK INTO THE SAME LOCATION. | | 3) IF THERE IS ANY WORK TO BE DONE ON THE WATER PIPING, | | WATER-HAMMER ARRESTORS SHALL BE INSTALLED WHERE QUICK | | CLOSING VALVES ARE UTILIZED ( ICE MAKER/WATER DISPENSER | | FROM REFRIGERATOR OR DISHWASHER). | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
|