Plan Review Stops For Permit 15030355 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2015-04-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-24 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-24 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2015-04-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-16 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-16 |
Time |
10:17 |
Sent To |
|
|
Notes |
2015-04-16 10:48:47 | PLAN REVIEW COMMENTS | | | | 2ND REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE WIND LOAD CALCULATION DOCUMENTS THAT WERE | | SUBMITTED FOR PUBLIC RECORD, WHICH ARE SIGNED BY THE | | P.E. (DANIEL MOSS) ARE REQUIRED TO BE SEALED. FS 471 | | AND FAC 61G15-23.002. (REPEAT COMMENT.) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-09 |
Time |
16:39 |
Sent To |
|
|
Notes |
2015-04-09 17:55:54 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE WIND LOAD PROGRAM DOCUMENTS ARE BARELY LEGIBLE | | AND NOT CLEAR ENOUGH TO BE USED FOR PUBLIC RECORD. FBC | | 107.2.1.4 | | | | 2) THE PLANS INDICATE THAT THE STRUCTURE IS LOCATED IN | | EXPOSURE C AND THE WIND LOAD DOCUMENTS THAT WERE | | SUBMITTED ARE DIFFICULT TO SEE BUT APPEAR TO SPECIFY | | EXPOSURE B. THE COMPONENT PRESSURES FOR THE DOORS | | APPEAR TO BE FOR A STRUCTURE WITH A MEAN ROOF HEIGHT | | LESS THAN 15 FEET LOCATED IN EXPOSURE D WITH A 170 MPH | | VULT WIND SPEED. FBC 107.2.1 & FBC-R 301.2.1.4 | | | | 3) THE WIND LOAD SUBMITTAL DOCUMENTS WHICH ARE SIGNED | | BY THE P.E. (DANIEL MOSS) ARE REQUIRED TO BE SEALED. FS | | 471 AND FAC 61G-15. | 2015-03-11 15:23:43 | COORDINATE WITH ART LANGE. STOP WORK ORDER ISSUED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2015-04-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-24 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-24 |
Time |
08:06 |
Sent To |
|
|
Notes |
2015-04-24 08:07:45 | INSTALL SMOKE ALARMS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
17:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-09 |
Time |
16:39 |
Sent To |
|
|
Notes |
2015-04-09 17:58:39 | THE ELECTRICAL PLAN THAT WAS SUBMITTED INDICATES THAT | | ALL OF THE ELECTRICAL WORK IS EXISTING. | 2015-03-11 15:23:23 | ELECTRICAL PLAN SUBMITTED. COORDINATE WITH ART LANGE. | | STOP WORK ORDER ISSUED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2015-04-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-24 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-23 |
Time |
17:21 |
Sent To |
|
|
Notes |
2015-04-23 17:21:13 | TO RM DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2015-04-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-16 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-13 |
Time |
17:13 |
Sent To |
|
|
Notes |
2015-04-13 17:13:28 | TO RM DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
17:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-03-10 |
Time |
19:44 |
Sent To |
|
|
Notes |
2015-03-10 19:44:49 | COORDINATE WITH ART LANGE. STOP WORK ORDER ISSUED. | | SENT TO R18 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2015-04-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
17:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2015-04-09 |
Time |
17:59 |
Sent To |
|
|
Notes |
2015-04-09 18:01:01 | THE EXTENT OF PLUMBING WORK IS TO REMOVE AND REPLACE | | THE FIXTURES IN THE SAME LOCATIONS. |
|
|